background image

ZME_05459
Wall Blind Control Set for Busch-Jaeger DURO 2000

Firmware Version : 1.8

Quick Start

A

 This device is a Z-Wave Actuator. Triple click one of the buttons on the device will include the device. A green blinking of LED will

indicate successful inclusion. The device is excluded by triple click to one of the buttons.

Please refer to the chapters below for detailed information about all aspects of the products usage.

What is Z-Wave?

This device is equipped with wireless communication complying to the Z-Wave standard. Z-Wave is the international standard for wireless
communication in smart homes and buildings. It is using the frequency of 868.42 MHz to realize a very stable and secure communication.
Each message is recon rmed (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed
network) in case the receiver is not in direct wireless range of the transmitter.

Z-Wave differentiates between Controllers and Slaves. Slaves are either sensors (S) transmitting metered or measured data or actuators (A)
capable to execute an action. Controllers are either static mains powered controllers (C) also referred to as gateways or mobile battery
operated remote controls (R). This results in a number of possible communication patterns within a Z-Wave network that are partly or
completely supported by a speci c device.

1. Controllers control actuators
2. Actuators report change of status back to controller
3. Sensors report change of status of measured values to controller
4. Sensors directly control actuators
5. Actuators control other actuators
6. Remote controls send signals to static controllers to trigger scenes or other actions
7. Remote controls control other actuators.

There are two different role a controller can have. There is always one single primary controller that is

managing the network and including/excluding devices. The controller may have other functions - like control

buttons - as well. All other controllers don't manage the network itself but can control other devices. They are called secondary controllers. The image also shows that

its not possible to operate a sensor just from a remote control. Sensors only communicate with static controllers.

Product description

The Z-Wave.Me Flush Mountable Motor Control is a wireless actuator able to control 230 V powered motors for blinds and jalousies. The
device is delivered as a complete set with  ush mountable insert, paddle and mounting frame compatible to the design of the switching
series DURO 2000 SI in color pearl white from Busch Jaeger. The paddle of the device is used to control the device itself but can also be
con gured to activate scenes in a central IP gateway or controller. The status of the motor control is indicated on a dual color LED for test
purposes and every status change is - if con gured - reported to a central IP gateway or controller. The function of the local paddle can be
con gured as detached from the local operation. In this local control different devices are controlled by Z-Wave while the local actuator is
controlled by other devices using Z-Wave. This device is designed for a 3 wire system and needs a neutral wire in the wall box.

Before Device is installed

Please read carefully the enclosed user manual before installation of the radio-actuator, in order to ensure an error-free functioning.

ATTENTION: only authorized technicians under consideration of the country-speci c installation guidelines/norms may do works with 230 Volt
mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Summary of Contents for ZME_05459

Page 1: ...er actuators There are two different role a controller can have There is always one single primary controller that is managing the network and including excluding devices The controller may have other functions like control buttons as well All other controllers don t manage the network itself but can control other devices They are called secondary controllers The image also shows that its not poss...

Page 2: ...ed to be connected to the cable to the load The cable from the load is connected to neutral N If there are both neutral and hot wire in the wall box the neutral from the mains panel and the neutral to the lamp need to be connected It is not harmful if the two connections L and S are mismatched on the actuator A fuse protects the electronics of the actuator The fuse is accessible on the top side of...

Page 3: ...te operation functions to the double click of the paddles Child Protection The device can be turn into a child protection mode In this mode all local operation is disabled The child protection mode MUST be turned on wirelessly However in protected by sequence mode it is possible to unlock the device for local operation with a triple click The unlock state will last for 5 seconds LED Control Red an...

Page 4: ...Default 1 Ignore 2 Open 3 Open if closed else close Full close time Parameter Number 4 Parameter Size 1 Time to go from opened to closed state Used to estimate the current level Note that in Permanent motion mode the reported value would a be Closed or Opened while all Basic and Multilevel Set values 1 99 255 would Open except 0 value that would Close Value Description 0 Keep in permanent motion 1...

Page 5: ... and close relays if blind control is wired to the motor incorrectly Value Description 0 No Default 1 Yes Typical click timeout Parameter Number 10 Parameter Size 1 Typical time used to differentiate click hold double and triple clicks Value Description 1 100 in 10ms units Default 50 Invert buttons Parameter Number 11 Parameter Size 1 Value Description 0 No Default 1 Yes Switch by buttons Paramete...

Page 6: ...ck timeout to see if the second click would be pressed This will introduce a small delay for single click commands Value Description 0 Disabled Default 4 Switch On Off and Dim send Basic Set and Switch Multilevel 1 Switch On Off only send Basic Set 2 Switch All 3 Send Scenes 5 Send Precon gured Scenes Send the following Switch All commands Parameter Number 15 Parameter Size 1 Value Description 1 S...

Page 7: ...d Classes Basic version 1 Multilevel Switch version 3 All Switch version 1 Multi Channel version 2 Scene Activation version 1 Technical Data Power Supply 230V 50 60 Hz Attachable Loads Motors up to 1800 W Fuse Type T 1 25 A H Load 1 25 Ampere high shutdown capacity D 5 mm L 20 mm IP Rating IP 20 Frequency 868 42 MHz SRD Band Wireless Range up to 100 m outside on average up to 20 m inside buildings...

Page 8: ...sociation is a control relationship between a controlling device and a controlled device Wakeup Noti cation is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guidelines The product does not contain hazardous chemicals Do...

Reviews: