Value
Description
0
Disabled (Default)
1 — 232 Node Id
On which command from blocking node to enable the protection (Parameter Number 7, Parameter Size 1)
De nes which command from blocking device to interpret as closed door and hence, unprotected.
Value
Description
0
on On (Default)
1
on Off
Stop or Revert if opposite button is pressed (Parameter Number 8, Parameter Size 1)
De nes behaviour on open press while closing and vice versa. To allow Stop behavior when switched by remote, use Stop by Basic
Value
Description
0
Stop (by buttons and Binary) (Default)
2
Stop (by buttons, Binary and Basic)
1
Revert
Invert open and close relays (Parameter Number 9, Parameter Size 1)
Allow exchanging open and close relays if blind control is wired to the motor incorrectly
Value Description
0
No (Default)
1
Yes
Typical click timeout (Parameter Number 10, Parameter Size 1)
Typical time used to differentiate click, hold, double and triple clicks
Value
Description
1 — 100 in 10ms units (Default 50)
Invert buttons (Parameter Number 11, Parameter Size 1)
Value Description
0
No (Default)
1
Yes
Switch by buttons (Parameter Number 12, Parameter Size 1)
If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In this mode
buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF
commands only.
Value
Description
0
No
1
By single press and hold (Default)
2
By double press and press-hold
Action on button single press or hold (Parameter Number 13, Parameter Size 1)