12
Doc# 27-0041UM Rev B Issued 7/13/2012
OPERATIONS
This section will provide information and assistance with the following topics
:
•
Powering up the ZX2 Station
•
ZX2 Status Information & Indicators
•
Inserting & Removing Tranzpak2 Storage Modules
4.0 OPeRATIONS
4.1 POwERING ON ThE ZX2 STATION
1. To power up the ZX2, press and hold
(about 1 second) the Power Supply Switch
at the center right side of the unit.
2. The display may possibly indicate
items that require attention. If such is the
case, please refer to the “Troubleshooting”
in the Appendix.
The ZX2 features status lights to effectively monitor the activities of the product:
Power On LED
1. Amber = 5V standby available, system is
in standby (meaning OFF) mode.
2. Green = system is ON.
3. OFF = system is not connected to an AC
power source
Power Switch
OT (Over Temp) LeD
1. OFF = system temperature is normal
2. Red = system temperature is reaching
critical condition. User intervention is
needed.
LAN LED 1 and 2
1. Blinking green = LAN port is connected and
functioning normally
2. OFF = LAN port is not connected and/or
disabled
HD LEDs
1. OFF = No hard drive activity or no hard
drive connected
2. Blinking amber = Indicates hard drive
activity
HEATER LED
1. RESERVED – Only in use for systems
with optional heater
Fan LeD – (LeD with “Fan” text and fan symbol)
1. Green = system fans are running normally
2. Amber = one or more system fans is malfunctioning
3. ReD = all system fans are malfunctioning or system fans are not installed
4.2 ZX2 STATUS INFORMATION & INdICATORS