09915
ZPrinter
650
Troubleshooting
Guide
60520: HP11 COMMANDSPI: timed out
The PC104+ card cannot read the pogo card
Monitor Read-Out or
Secondary
Symptom
Cause / Problem
Solution
Reference
Documents
60520: HP11
COMMANDSPI: timed out
Bad Carriage Cable
Replace 50080 Pogo Flex
Cable
85026 ZPrinter 650
Carriage Cable Removal
and Replacement
After performing the above step try performing a service print head and alignment. If the machine performs both tasks
the problem should be solved.
60520: HP11
COMMANDSPI: timed out
Bad Pogo PCB
Replace 50019 Pogo PCB
85022 ZPrinter 650 Pogo
PCB Removal and
Replacement
After performing the above step try performing a service print head and alignment. If the machine performs both tasks
the problem should be solved.
60520: HP11
COMMANDSPI: timed out
Bad slow axis festoon
cable
Replace 50108 Festoon
Cable Assembly
(Figure 1)
60520: HP11
COMMANDSPI: timed out
PC104+ Failed
Replace 50016 PC104+
PCB
85070 ZPrinter 650 E-Box
Field Repair Procedure
The most common cause of this error is a cable disconnect, bad cable or a bad pogo. This error can be diagnosed
through the control panel on the machine by going through the PC104+ and Pogo tests.
10040: POGOSTATUSSPI: timed out
The PC104+ card cannot read the pogo card
Monitor Read-Out or
Secondary
Symptom
Cause / Problem
Solution
Reference
Documents
70400: POGOSTATUSSPI:
timed out
Bad Carriage Cable
Replace 50080 Pogo Flex
Cable
85026 ZPrinter 650
Carriage Cable Removal
and Replacement
After performing the above step try performing a service print head and alignment. If the machine performs both tasks
the problem should be solved.
70400: POGOSTATUSSPI:
timed out
Bad Pogo PCB
Replace 50019 Pogo PCB
85022 ZPrinter 650 Pogo
PCB Removal and
Replacement
After performing the above step try performing a service print head and alignment. If the machine performs both tasks
the problem should be solved.
70400: POGOSTATUSSPI:
timed out
Bad slow axis festoon
cable
Replace 50108 Festoon
Cable Assembly
(Figure 1)
While print heads may cause this error the most common cause of this error 50108 Slow Axis Festoon Cable+. This
error may be diagnosed through the control panel on the machine by going through the PC104+ and Pogo tests.
24