Install-TOMMI - JUN_2020 - 2020-06-18.docx www.yunca.co.nz
Page 8 of 15
FIG D: FLUE SYSTEM REQUIREMENTS
(Not to scale)
IMPORTANT INFORMATION
A. THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN COMPLIANCE
WITH AS/NZS 2918:2001 AND THE APPROPRIATE REQUIREMENTS OF THE
RELEVANT BUILDING CODE OR CODES.
B. APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL
COMPLY WITH THE REQUIREMENTS OF AS/NZS 4013 WHERE REQUIRED BY THE
REGULATORY AUTHORITY I.E. THE APPLIANCE SHALL BE IDENTIFIABLE BY A
COMPLIANCE PLATE WITH THE MARKING “TESTED TO AS/NZS 4013”
C. ANY MODIFICATION OF THE APPLIANCE ,THAT HAS NOT BEEN APPROVED IN
WRITING BY THE TESTING AUTHORITY, IS CONSIDERED TO BE IN BREACH OF
THE APPROVAL GRANTED FOR COMPLIANCE WITH AS/NZS 4013
D. MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT
SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS
MAY RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS
CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST
INSTANCE.
E. CRACKED AND BROKEN COMPONENTS E.G. GLASS PANELS OR FIRE BRICKS,
MAY RENDER THE INSTALLATION UNSAFE.
F. SEISMIC RESTRAINT:
• Secure the heater base to the hearth or sub-framing with Dynabolts or similar.
• Follow local Council’s Specifications.
More than 3000
3000
or less
6
0
0
m
in
.
3000
1000 min. if clear
within 3000 of
flue top
.
3000
Any nearby
structure
.
1000 min. if clear
within 3000 of
flue top
MINIMUM HEIGHT OF FLUE SYSTEM EXIT
NOTE : Dimensions are in millimetres
3000
or less
6
0
0
m
in
.
More than 3000
3000
.
Increase from
1000 min. until
clear within
3000 of flue top