09-06-01
Page 18 of 18 op-instruct-leedz-ib.doc
13. The pilot jet can be now removed. Insert new pilot jet from conversion kit ensuring the
chamfered end is facing upwards.
14.
Back Burner Controller outlet Change
. When changing from N.G. to LPG, the in line
restrictor, located in the rear burner pipe where it attaches to the control, must me removed.
When changing from LPG to NG, this restrictor (Cone facing Out) must be placed in rear
burner pipe at the control.
15.
Front Burner Controller outlet Change.
The brass reducer that couples the front burner
pipe to the control must also be changed and the reducer supplied with kit fitted. (LPG 8mm
Bore/ Natural 1.7 mm Bore.
16.
Inline Regulator.
From
Natural
Gas
: Remove the Inline regulator that’s before the Control Valve.
To
Natural
Gas
: Install the Inline regulator and pipe before the Control Valve.
17. Reconnect the Gas pipes and resemble main burner module.
18.
Test all connections for gas tightness
and replace logs and door.