The model pH100A is one of three instruments in the EcoSense product line from YSI.  The 
pH100A is a precision tool that measures pH, mV and temperature. A built-in microprocessor 
stores, calculates and compensates for all parameters related to pH determinations including 
pH electrode temperature characteristics, electrode slope deviations and buffer solutions. 

This instrument is waterproof (IP67) when the connector cap is installed. The mechanical 
touch keys are highly reliable with tactile and audio feedback. This meter uses one 9V battery. 
Re-calibration is not required when power is restored. 
The front of the meter has a large LCD that displays pH or mV and temperature 
simultaneously along with user prompts and mode indicators. The unit prompts the user 
through calibration and measurement procedures. 

An AUTOLOCK feature for both pH and mV measurements enables the unit to automatically 
sense the end point and "lock" the display to indicate the end point value of a measurement. 
The pH100A can also be used in non-AUTOLOCK mode. AUTOLOCK and user prompts help 
eliminate most errors in determining pH and mV values, resulting in precise, repeatable, 
error-free measurements. 

The model pH100A is available with pH, mV, ORP and ATC (Automatic Temperature 
Compensation) probes. Other features include electrode offset recognition, electrode slope 
recognition, electrode efficiency display, built-in buffer coefficients, automatic or manual 
temperature compensation, long battery life, 50 data set memory and 50/60 Hz AC noise 
rejection. This meter is universal, user-friendly, for field, industrial and laboratory applications. 

INITIAL INSPECTION 

Carefully unpack the unit and accessories, and inspect for shipping damages. Compare 
received parts with materials listed on the packing list. Notify YSI immediately of any damage 
or missing parts. Save all packing materials until satisfactory operation is confirmed. 

THE INSTRUMENT 

Though the instrument is housed in a water-proof IP67 case, DO NOT use it underwater.  The 
connector is not waterproof unless the cap cable is installed. In case of submersion without 
the cap connected, follow these steps immediately:  

1.

Rinse unit carefully with distilled water. After rinsing and drying, inspect and clean 
connectors to remove all contaminants that may affect probe connections.

2.

Wait for the unit and probe to dry completely before resuming operation.

3.

If the unit does not function correctly after steps 1 and 2, call YSI for possible repair or 
replacement (see Warranty).

BATTERY INSTALLATION 

An initial display of “BAT” on the LCD indicates approximately one 
hour of battery life for unit operation within specifications. Replace 
battery when “BAT” appears on the LCD. (See Figure 1.) 
To replace battery, remove the two battery cover screws and 
battery cover and o-ring. Replace the 9V battery. Replace battery 
cover and o-ring (align the o-ring properly to insure a good seal) 
and fasten the two battery cover screws for the splash-resistant 
feature. 

Battery Disposal  

This instrument is powered by a 9 volt battery, which the user must remove and dispose of 
when the batteries no longer power the instrument. Disposal requirements vary by country 

Figure 1.  
Battery Installation 

Summary of Contents for EcoSense pH100A

Page 1: ...Operations Manual EcoSense pH100A Portable pH mV and Temperature Instrument English ...

Page 2: ...isposal 3 KEY FUNCTIONS OF THE MODEL pH100A 4 THE LCD DISPLAY 4 OPERATIONAL PROCEDURES 4 Buffer Set Selection 4 pH Calibration 5 Using the model pH160 Electrode Simulator 5 pH Measurements 5 Temperature Measurements 6 mV Measurements 6 Saving Viewing and Deleting Data 6 TROUBLESHOOTING 7 SPECIFICATIONS 7 ...

Page 3: ...et memory and 50 60 Hz AC noise rejection This meter is universal user friendly for field industrial and laboratory applications INITIAL INSPECTION Carefully unpack the unit and accessories and inspect for shipping damages Compare received parts with materials listed on the packing list Notify YSI immediately of any damage or missing parts Save all packing materials until satisfactory operation is...

Page 4: ...ternal memory When ESC is pressed for 2 seconds all LCD elements light After about 2 seconds the unit enters pH AUTOLOCK mode AUTOLOCK displays and STAND begins to flash indicating the need for calibration THE LCD DISPLAY 1 WAIT Displays while unit waits for a stable reading or end point sensing 2 BAT Low battery indicator 3 ATC MAN ATC displays if an ATC probe is connected Otherwise MAN displays ...

Page 5: ... calibrated and ready for measurements After calibration press and hold MEA EFF for about 5 seconds to display the new electrode efficiency Using the model pH160 Electrode Simulator The model pH160 Electrode Simulator can be used to confirm proper instrument calibration To use the simulator 1 Install the 9V battery provided 2 Attach the pH160 to the pH100A Turn both units on The pH160 has a small ...

Page 6: ...SAVE and the record number for one second Full is displayed when trying to save data and the memory is full To view saved data press mode until RECALL is displayed and then press ESC Use the Up or Down arrow keys to review different saved records Press Mode to escape back to measurement mode To delete data records press Mode while in measurement mode until DELETE is displayed Press ESC All will be...

Page 7: ...r temperature within range Return for service OvEr Undr Measured pH is out of the 16 00 2 00 pH range Measured mV is out of the 1250 2000 mV range Measured temperature is out of the 10 120 C range Bring the out of range unit into the correct measuring range If units are within proper range return product for service SPECIFICATIONS Display Range Accuracy Resolution pH 2 00 to 16 00 pH 0 1 2 lsd 0 0...

Reviews: