FEATURES OF THE YSI 550A  

 

KEYPAD  

 

   

 

Powers the unit on or off.  The instrument will activate all segments of the display for 
a few seconds, and then will show a self-test procedure for several more seconds. 
During this power on self-test sequence, it is normal to error messages appear and 
disappear.  If the instrument were to detect a problem, a 

continuous

 error message 

would be displayed.  

 

   

 

Turns the display backlight on or off.  The light will turn off automatically after two 
minutes of non-use. 

 

Mode

     

During DO calibration it allows the user to select between % and mg/L.  After 
selection, it may be pressed several times to exit back to measurement mode without 
completing the calibration.  During measurement, it switches the instrument display 
between DO %, DO mg/L, and salinity calibration. 

 

 

and

 

   

Increases or decreases the value during calibrations. 

 

  and  

Mode 

  

Press at the same time to switch the temperature units between Fahrenheit (F) and 
Celsius (C). 

 

 

  and  

Mode 

  

Press at the same time to increase or decrease the resolution of the instrument in 
mg/L or % measurement mode. 

 

BATTERIES 

 
The YSI 550A DO Instrument is powered by 4 C-size alkaline batteries. A new 
set of alkaline batteries will provide approximately 2000 hours of continuous 
operation. When batteries need to be replaced, the LCD will display a 

"LO 

BAT"

 message. When the message first appears, the instrument will have 

approximately 50 hours of life left, provided the back light is not used.  
 

INSTRUMENT CASE 

 
The waterproof instrument case is sealed at the factory and is not to be opened, except by authorized 
service technicians

 

Caution:  

Do not attempt to separate the two halves of the instrument case as this may damage the 

instrument, break the waterproof seal, and will void the manufacturer's warranty. 

 

Summary of Contents for 550A

Page 1: ...Operations Manual YSI 550A Dissolved Oxygen Instrument...

Page 2: ......

Page 3: ...S OF THE YSI 550A 3 PRINCIPLES OF OPERATION 5 PREPARING THE PROBE 5 DISSOLVED OXYGEN CALIBRATION 6 SALINITY COMPENSATION CALIBRATION 7 PROBE OPERATION 8 PROBE ELECTRODE MAINTENANCE 9 ACCESSORIES REPLA...

Page 4: ......

Page 5: ...gle calibration regardless of which dissolved oxygen display is used and will calibrate in either mode Salinity compensation values can be changed at any time without performing a new calibration A de...

Page 6: ...to the Authorized Service Center selected by YSI Repair or replacement will be made and the product returned transportation prepaid Repaired or replaced products are warranted for the balance of the...

Page 7: ...and salinity calibration and Increases or decreases the value during calibrations and Mode Press at the same time to switch the temperature units between Fahrenheit F and Celsius C and Mode Press at t...

Page 8: ...the instrument by unscrewing the two screws 2 Remove the rubber stopper from the chamber by pulling the tail free of the small hole on the chamber 3 Re attached the rubber stopper to the storage chamb...

Page 9: ...causes the probe current to change proportionally PREPARING THE PROBE MEMBRANE CAP INSTALLATION The YSI 550A DO probe is shipped with a dry protective membrane Before using the instrument for the firs...

Page 10: ...mation can be obtained over the internet or from a local airport or weather station To convert from meters to feet divide by 0 3048 For best results Check calibration with each use and recalibrate as...

Page 11: ...ess and release both the UP ARROW and DOWN ARROW keys at the same time to enter the calibration menu 4 Press the Mode key until mg L is displayed on the right side of the screen for oxygen units Press...

Page 12: ...hrough the sample 3 Allow temperature and dissolved oxygen readings to stabilize 4 Observe Record readings 5 If possible rinse the probe with clean water after each use PRECAUTIONS 1 Membranes last lo...

Page 13: ...ne does not resolve the problem then proceed with the chemical cleaning Mechanical cleaning Sand off the dark layer from the silver anode with 400 grit wet dry sandpaper Wrap the wet sandpaper around...

Page 14: ...the hex screw was removed completely make sure that it is not cross threaded when replaced 7 The YSI 559 DO module is shipped with a dry protective membrane Before using for the first time remove the...

Page 15: ...module Dissolved Oxygen Response Time 95 of end value in 9 seconds Temperature Units Celsius or Fahrenheit user selectable Parameter Compensation Automatic temperature compensation for dissolved oxyge...

Page 16: ...Return system for service 4 Instrument readings are inaccurate A Verify calibration altitude and salinity settings are correct and recalibrate B Probe may not have been in 100 water saturated air duri...

Page 17: ...Main display reads Err or burn and Secondary display reads EEP A Return system for service CONTACT INFORMATION YSI offers a wide range of customer assistance and technical support functions to ensure...

Page 18: ...y from the receiver plug the YSI Instrument into a different outlet so that the computer and receiver are on different branch circuits If necessary the user should consult the dealer or an experienced...

Reviews: