TROUBLESHOOTING
Problem
Cause
Corrective Action
NO LIGHTING
Lamp fault
Replace Lamp
Lamp connected with secondary
plug
Connect to circuit
2
ND
PLUG OF TR DIS-CONNECTEDTR Connect to connector
TR DEFECT
Replace
the
defective
isolating transformer
LOW
INTENSITY(BRIGHTNESS
Lamp fault
Replace Lamp
INSIDE DUST
CLEANING
WATER INLET
Refer to below clause
Control part faulty
Replace Control part
WATER
INLET(PENETRATON)
Damage of connect cable
Replace connect cable
PRISM SETTING IS NOT GOOD.
PRISM CHANGE
GASKET-O RING DAMAGE
GASKET CHANGE