Page 11
91000-90(B)
Z.SDI
Y
TX.B
RX.A
REF
+PWR
-PWR
EARTH GND
WHT
GRN
BRN
RED
BLK
Earth Ground
(+)
(-)
Supply Voltage 10-30 VDC
80mA max
Sensor TX/RX (Inverted signal)
Sensor TX/RX (Non-inverted signal)
Signal Reference
SDI
Z
B
A
TX
RX
P2
JUMPER
SETTINGS
Output Mode: RS-485 Half Duplex
Output Format: ASCII, ASCII POLLED, or NMEA
Baud Rate: 1200, 4800, 9600, 19200 or 38400
Set serial device baud rate to match
ResponseONE
.
1 start bit, 8 data bits, no parity, 1 stop bit, no flow control.
Use shielded cable. Connect cable shield to earth ground as shown.
(Color code is for Young 18446 Cable)
Figure A3: RS-485 / RS-422 SERIAL CONNECTION - HALF DUPLEX
Serial Device
SETTINGS
Output Mode: RS-485 Output Only
Output Format: ASCII, or NMEA
Baud Rate: 1200, 4800, 9600, 19200 or 38400
Set serial device baud rate to match
ResponseONE
.
1 start bit, 8 data bits, no parity, 1 stop bit, no flow control.
Use shielded cable. Connect cable shield to earth ground as shown.
(Color code is for Young 18446 Cable)
Figure A4: RS-485 / RS-422 SERIAL CONNECTION - OUTPUT ONLY
Serial Device
SDI
Z
B
A
TX
RX
P2
JUMPER
Z.SDI
Y
TX.B
RX.A
REF
+PWR
-PWR
EARTH GND
WHT
GRN
BRN
RED
BLK
Earth Ground
(+)
(-)
Supply Voltage 10-30 VDC
80mA max
Sensor TX (Z Inverted signal)
Sensor TX (Y Non-inverted signal)
Signal Reference
92000
RESPONSE ONE
APPENDIX A: WIRING CONNECTIONS
Summary of Contents for ResponseONE 91000