background image

S t a g e   L i g h t i n g

LP-LED2

2

When the LP-LED2 is operated by itself (stand alone) there are a number of modes which are 

determined by the FUNCTION control:

OFF
Dimming (7 levels)
Color fade (4 speeds)
Mixed fade (4 speeds) 

When used in the dimming mode, the color of each fixture is determined by the corresponding 

COLOR control. Any fixture can be turned off by setting the COLOR control to the off position. 

There are 15 colors and color choices start with red, then blue, white, amber yellow and finally 

green. There are several choices of color temperature for white. The color fade speeds are fairly 

slow and are intended for gradually changing mood lighting. 

External Control and the CH Assign Switch

All Yorkville lighting products and controllers can issue or receive four channels of lighting data on 

a single XLR connector  The CH Assign switch on the LP-LED2 allows you to select which of the 

four incoming channels will control the two heads of the LP-LED2 when using an external control-

ler or another light bar as a master controller.

DMX Module

The DMX module installs in a cutout in the chassis. It is necessary to connect to an internal cir-

cuit board with a jumper cable supplied with the DMX module. Operating instructions for the DMX 

mode are supplied with the DMX module.

Yorkville Sound LP-608 Lighting Controller 

When operating with the Yorkville Sound LP-608 lighting controller the COLOR controls on the 

LP-LED2 remain active. The COLOR control can be used to select the color of each fixture. If the 

COLOR control is set to off, then the LP-608 intensity control becomes the color control (including 

off) but the intensity is not controllable.

Note: Operation with the LP-608 controller will require a 'gender reversing' adapter in line with the XLR 

cable. This was done to prevent accidental connection to a DMX controller possibly causing damage.

Using Multiple LP-LED2s 

Multiple LP-LED2 units may be linked with a standard 3-pin XLR cable. When the first unit in the 

chain is not receiving a control signal its controls are active and the downstream units are controlled 

by the first. All downstream units will have their controls disabled except for the Ch. Assign Button.

Mounting

The LP-LED2 will mount on a standard loudspeaker stand or C clamps can be fitted to any of the 

4 threaded mounting points. (See Diagram 4)

Power Consumption

The advantage for using LED versus conventional incandescent lighting is two-fold. Not only does 

the unit give off much less heat but also consumes less than 5% to 20% of the energy. This elimi-

nates the need for separate AC power circuits just to run the lights. 

Power consumption is under 150 watts depending on color choice and intensity. The light fix-

tures and the base are fan cooled. The AC connector will mate with a standard IEC cable or with a 

special locking cable (provided). Line voltage can be anywhere from 100 to 240 volts AC.

Specifications

LP-LED2

Max AC Input Voltage 100-240VAC 50/60 Hz

Power Consumption LEDs 16 Watts per LED, 4 LEDs per head, 64 Watts total

Power Consumption MAX150 Watts

Stand Mount Size 1 3/8 inch Round

Controller Cable Standard Shielded 3-pin XLR Cable

Other Optional DMX Module

Dimensions (LWH) (TBD) inches

(TBD) cm

Weight

(TBD) lbs

(TBD) kg

Summary of Contents for LP-LED2

Page 1: ...Owner s Manual Manuel d Utilisteur S t a g e L i g h t i n g L i g h t b a r LP LED2 ...

Page 2: ...n spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped AVIS AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE N ENLEVEZ PAS LE COUVERT OU LE PANNEAU ARRIERE NE CONTIENT AUCUNE PIECE REPARABLE PAR L UTILISATEUR CONSULTEZ UN TECHNICIEN QUALIFIE POUR L ENTRETIENT Instructions relatives au risque de feu choc élec...

Page 3: ...am has a diameter of 2 feet at a distance of 6 feet The diameter is 4 feet at a distance of 12 feet The light is mixed in the lens so that the mixed light color is visible when looking at the lens Each fix ture may be adjusted in 2 axis The LP LED2 may be used in several ways 1 Stand alone 2 With a separate controller 3 Linked to other LP LED2s with one as master 4 Controlled by DMX signals throug...

Page 4: ...re If the COLOR control is set to off then the LP 608 intensity control becomes the color control including off but the intensity is not controllable Note Operation with the LP 608 controller will require a gender reversing adapter in line with the XLR cable This was done to prevent accidental connection to a DMX controller possibly causing damage Using Multiple LP LED2s Multiple LP LED2 units may...

Page 5: ... est de 4 pieds à une distance de 12 pieds La lumière est mélangée dans la lentille de sorte que la couleur de la lumière mixte est visible quand on regarde l objectif Chacun des dispositifs peut être ajustée dans 2 axes Le LP LED2 Peut Être Utilisé de Plusieurs Façons 1 Autonome 2 Avec un contrôleur séparé 3 Lié à d autres LP LED2 dont un comme contrôleur principal 4 Commandés par des signaux DMX...

Page 6: ...rôle de la couleur est à la position OFF le contrôle d inten sité du LP 608 devient le contrôle de la couleur y compris off mais l intensité n est pas contrôlable Remarque Le fonctionnement avec le contrôleur LP 608 nécessitera un adaptateur inverseur de genre en ligne avec le câble XLR Cela a pour but d empêcher une connexion accidentelle à un contrôleur DMX qui pourrait causer des dommages Utili...

Page 7: ...H Assign 1 2 3 4 Hook Up with Controller Raccordement à un Contrôleur Link to Additional LP LED Units Optional Raccordement à des Unités LP LED Supplémentaires Optionnel LP LED2 1 LP LED2 2 Optional Link to Additional LP LED Units Optionnel Raccordement à des Unités LP LED Supplémentaires Out Sortie In Entrée Out Sortie S t a g e L i g h t i n g L i g h t b a r LP LED2 DESIGNED MANUFACTURED BY YOR...

Page 8: ... Designed to use 5 16 Hex Bolt Conçu pour utiliser des Boulons Hexagonal 5 16 NOTE A lock washer MUST be used on each bolt REMARQUE Une rondelle de blocage DOIT être utilisée sur chaque boulon Mounting Points for Optional Hardware Points de Montage pour Quincaillerie Optionnelle ...

Page 9: ...e de faire enregistrer votre nom auprès de Yorkville Sound ou de votre détaillant Si pour une raison quelconque ce produit devient défectueux durant les deux années qui suivent la date d achat initial dix ans pour l ébénisterie retournez le simplement à votre détaillant Yorkville avec la preuve d achat original et il sera réparé gratuitement Ceci inclus tous les produits Yorkville à l exception de...

Page 10: ... Estate Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 Manual Owners LP LED2 00 1v1 October 30 2012 ...

Reviews: