![background image](http://html1.mh-extra.com/html/york/yzf02413/yzf02413_technical-manual_913570014.webp)
14
Johnson Controls Unitary Products
632151-YTG-A-1010
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
ACCESSORIES*
TXV Kits -
1TVM9 series thermal expansion valves precisely
meter refrigerant for optimum performance.
Bonnet Sensor (2SB13700124) -
The bonnet sensor is used to
sense plenum temperature, and is optional with a gas or oil
back-up heat source. Compatible only with 13 SEER and higher
heat pumps.
Dehumidistat (2HU16700124) -
Provides increased dehumidi-
fication when matched with variable speed furnace or air han-
dler.
Heat Pump Risers -
(526-35389-000, 526-35390-000, 526-
35391-000) - 3", 6", or 12" risers mount easily in composite
base pan recesses, ensuring the unit stays clear of snow and
ice build-up in harsh winter weather.
Thermostats
- Compatible thermostat controls are available
through accessory sourcing. For optimum performance and
installation, refer to the UPGNET “Low Voltage Wiring Diagram”
document to select and apply controls.
SOUND POWER RATINGS*
* Rated in accordance with ARI 270-95 Standards.
YZF06013(C)
(Y*(8,L)C/T*8V)*C20
FC64D
1
1060
42.5
–
–
3.48
2
1630
58.0
38.5
9.00
3.78
2
1060
58.0
39.0
9.00
3.30
(Y*9C/T*9V)*C16
FC64D
1
1040
42.5
–
–
3.46
2
1590
58.0
38.5
9.00
3.74
2
1040
58.0
39.0
9.00
3.28
(Y*9C/T*9V)*C20
FC64D
1
1040
42.5
–
–
3.46
2
1655
58.0
39.0
9.00
3.72
2
1040
58.0
39.0
9.00
3.28
(Y*9C/T*9V)*D20
FC64D
1
1085
42.5
–
–
3.46
2
1630
58.0
38.5
9.00
3.74
2
1085
58.0
39.0
9.00
3.28
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no sup-
plemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
MODEL
FURNACE MODEL
COIL
MODEL
1
HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF
COP @
47
47 OD
17 OD
1 PH HP WITH HIGH EFFICIENCY FURNACES
3
UNIT MODEL
(dBA)
Cooling
Heating
024
71.0
71.5
030
71.2
70.8
036
71.5
68.1
042
71.4
69.8
048
71.3
71.5
060
69.8
71.8