Model: YOHC -60
Cooling
OUTDOOR TEMPERATURE DRY
Indoor
Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
45ºC
50ºC
Total capacity kW
16.42
15.71
15.14
14.28
13.71
13.28
12.85
Sensitive capacity kW
13.14
12.57
12.11
11.42
10.97
10.62
10.28
21ºC D
15ºC W
Input kW.
3.78
4.32
4.86
5.40
5.94
6.48
7.02
Total capacity kW
17.99
17.20
16.58
15.64
15.01
14.55
14.08
Sensitive capacity kW
14.39
13.76
13.26
12.51
12.01
11.64
11.26
24ºC D
17ºC W
Input kW.
3.99
4.56
5.13
5.70
6.27
6.84
7.41
Total capacity kW
19.55
18.70
18.02
17.00
16.32
15.81
15.30
Sensitive capacity kW
15.64
14.96
14.42
13.60
13.06
12.65
12.24
27ºC D
19ºC W
Input kW.
4.20
4.80
5.40
6.00
6.60
7.20
7.80
Total capacity kW
22.48
21.51
20.72
19.55
18.77
18.18
17.60
Sensitive capacity kW
17.99
17.20
16.58
15.64
15.01
14.55
14.08
32ºC D
23ºC W
Input kW.
4.83
5.52
6.21
6.90
7.59
8.28
8.97
Indoor
Conditions
24ºC D
18ºC W
12ºC D
11ºC W
7ºC D
6ºC W
4ºC D
3ºC W
0ºC D
-1ºC W
-5ºC D
-6ºC W
-7ºC D
-8ºC W
-15ºC D
-16ºC W
Capacity kW
34.50
27.60
23.00
20.70
19.55
17.25
16.10
14.95
15ºC
Input kW.
10.35
8.28
6.90
6.56
6.21
5.87
5.52
4.83
Capacity kW
32.40
25.92
21.60
19.44
18.36
16.20
15.12
14.04
18ºC
Input kW.
9.72
7.78
6.48
6.16
5.83
5.51
5.18
4.54
Capacity kW
30.00
24.00
20.00
18.00
17.00
15.00
14.00
13.00
20ºC
Input kW.
9.00
7.20
6.00
5.70
5.40
5.10
4.80
4.20
Capacity kW
27.60
22.08
18.40
16.56
15.64
13.80
12.88
11.96
22ºC
Input kW.
8.28
6.62
5.52
5.24
4.97
4.69
4.42
3.86
Capacity kW
24.00
19.20
16.00
14.40
13.60
12.00
11.20
10.40
27ºC
Input kW.
7.20
5.76
4.80
4.56
4.32
4.08
3.84
3.36
Summary of Contents for YOHC 12
Page 7: ...Part 2 Indoor units Ceiling Floor Type ...
Page 17: ...4 Service space 600mm 600mm ...
Page 20: ...6 1 3 YOKC 24 6 1 4 YOKC 30 ...
Page 21: ...6 1 5 YOKC 36 6 1 6 YOKC 48 YOKC 60 ...
Page 30: ...Discharge angle 60 FLOOR Airflow velocity Temperature ...
Page 37: ...Part 3 Outdoor Units Outdoor Units ...
Page 39: ...1 Dimensions 1 1 YOJC 12 290 315 285 530 62 590 750 110 1 2 YOJC 18 12 5 ...
Page 40: ...1 3 YOJC 24 330 62 895 860 590 141 1 4 YOJC 30 YOJC 36 ...
Page 41: ...1 5 YOJC 48 YOJC 60 ...
Page 43: ...3 Wiring diagrams 3 1 Cooling Heating 3 1 1 YOJC 12 3 1 2 YOJC 18 ...
Page 46: ...4 Field Wiring ...
Page 49: ...7 Sound levels 1m Microphone 12000btu h 18000btu h ...
Page 50: ...24000btu h 3000btu h 36000btu h 48000btu h 60000btu h ...
Page 66: ...Part 4 Installation Installation ...
Page 75: ...www johnsoncontrols com SM YOHC 12 60GB 03 07 ...