  D A N G E R

It is strictly prohibited for the user to carry out any maintenance or upkeep tasks on the HVAC unit.
This appliance is not destined for use by people (including children) with limited physical, sensorial or

mental capacities, or without adequate experience or knowledge, unless they have received instructions

or been supervised in the use of the appliance by an individual responsible for their safety.
Children must be supervised at all times to ensure that they do not play with the appliance.
Only trained Johnson Controls Inc. personnel with the necessary means and tools may carry out main‐

tenance and upkeep work on the unit.
Trained personnel must be aware of the health and safety regulations and procedures applicable to

HVAC units. They should also be aware of general procedures and those applying specifically to this

unit.
Contact a Johnson Controls Inc. Authorised Technical Assistance Service for scheduled maintenance

on this unit.

PRODUCT DISPOSAL
According to Directive 2002/96/EC of the European

Parliament and of the Council of 27 January 2003, the

presence of the symbol on the product or in the docu‐

ments  included  with  the  product  indicates  that  this

product is classified, according to current law, as an

electrical  and  electronic  device  and,  therefore,  this

product cannot be dealt with at the end of its working

life as domestic or urban waste.
The product must be taken to collection points for the

recycling  of  waste  electrical  and  electronic  equip‐

ment.
The  appropriate  management,  reuse,  assessment

and recycling of these products protect human health

and the environment.

1

User manual

1.3

Regular maintenance activities for which the user is responsible

24

Summary of Contents for YLCA 50

Page 1: ...Air condensed water chillers and heat pumps YLCA 50 60 and 80 User manual Ref N 40289_EN 0910...

Page 2: ...rs relating to sensors 12 1 2 5 Parameters relating to the compressor 12 1 2 6 Operating graphics 13 1 2 7 Parameters relating to fans 16 1 2 8 Antifreeze control configuration parameters 17 1 2 9 Uni...

Page 3: ...1 User manual...

Page 4: ...compressor pump and electric heater start up By reading the control sensors and safety elements the controller protects the entire equipment against malfunctions The system allows con necting the uni...

Page 5: ...ved copper tubing mechanically expanded within the fin assembly Fans Of the axial and low sound level type Equipped with single phase motors with IP54 protection These motors allow speed control by me...

Page 6: ...rogen at 1 5 bar safety valve set to 6 bar water circuit pressure gauge two air bleed valves filling valve and drain valve Also includes a mesh filter for the water circuit This filter is supplied loo...

Page 7: ...f a water filter has not been installed Remote control Wall mounted remote control unit with keyboard for cool heat and ON OFF functions Includes power supply alarm and cool heat LEDs Maximum cable le...

Page 8: ...to sit This base must be solid and dimensioned in accord ance with the load to be supported The antivibratory support accessory for models YL CA YLHA 40 50 and 60 includes 4 units whereas for models...

Page 9: ...off functions Operating parameters can also be modi fied and the system can also be supervised Fan speed control module Operates by phase cut off Includes fuse NTC and ratiometric pressure sensors 3...

Page 10: ...sensors as well as other system values Can be used by the user without affecting unit operation General Modification of the parameters that affect basic unit configuration should be made with the con...

Page 11: ...pressure sensor Fan speed and de frost control D Compressor 1 ID1 Water flow switch E Alarm ID2 Fan heat switches F 230 24 transformer ID3 High pressure switch G Fan speed control ID4 Low pressure sw...

Page 12: ...Direct parameters Press for 5 seconds Selects a Direct parameter and shows its value Confirms parameter changes Press once 3 6 Parameter programming with password Press for 5 seconds 4 Selection of hi...

Page 13: ...HP E Indoor heat exchanger L Outdoor heat exchang er F NTC water inlet sensor B1 M Pressure sensor B4 G Pump Parameter tables The following tables show the parameters and their values divided into gr...

Page 14: ...5 R W 1 0 0 b00 Sensor viewed on display U 24 R W 7 0 0 b01 Value read by sensor B1 D 70 R C b02 Value read by sensor B2 D 71 R C b03 Value read by sensor B3 D 72 R C b04 Value read by sensor B4 D 73...

Page 15: ...erating time of a compressor A Signal B Compressor Min stoppage time of a compressor A Signal B Compressor Min time between compressor start ups A Signal B Compressor User manual 1 Operating instructi...

Page 16: ...1 C Compressor 1 B Signal 2 D Compressor 2 Time between stoppage of two compressors A Signal 1 C Compressor 1 B Signal 2 D Compressor 2 Compressor pump stoppage delays A Compressor B Pump 1 User manu...

Page 17: ...Pump compressor start up delays A Pump B Compressor User manual 1 Operating instructions C2 YLCA 50 60 and 80 1 2 15...

Page 18: ...Triac voltage F 49 R W step F04 0 35 F04 Maximum Triac voltage F 50 R W step 100 F03 92 F05 Cool cycle minimum speed pressure 24 R W bar 80 40 22 2 F06 Cool cycle maximum speed pressure dif ferential...

Page 19: ...ntifreeze sensor F 6 R W 1 0 0 A07 Minimum level antifreeze control set point tem perature U 15 R W C 79 40 3 A08 Heating heater activation set point tempera ture U 16 R W C r15 A01 3 A09 Heating heat...

Page 20: ...tal input 0 Absent 1 Present U 14 R W 1 0 0 H07 ON OFF digital input 0 Absent 1 Present U 15 R W 1 0 0 H08 Network configuration do not modify this parameter F 57 R W 3 0 0 H09 Keyboard locked 0 Disab...

Page 21: ...eat cycle F 19 R W 1 0 1 P08 Digital input 1 for flow switch Do not modify this parameter F 69 R W 1 P09 Digital input 2 for the remote Cool Heat function Do not modify this parameter F 70 R W 9 P15 L...

Page 22: ...4 only Maximum activation time Output tem perature F 80 R W Seconds 999 r09 120 r09 If r06 4 only Minimum activation time Output tem perature F 81 R W Seconds 999 c04 100 r10 If r06 4 only Maximum de...

Page 23: ...supply voltage Automatic EHS High supply voltage Automatic EPr Eprom error Unit operating Automatic EPb Eprom error At start up Automatic EL 1 2 Problem at fan voltage control Automatic FL Flow switch...

Page 24: ...s relating to sensors see on page 12 Remote ON OFF A remote ON OFF inlet can be connected between terminals D5 and B on the connecting strip To activate said inlet a value of 1 should be given to para...

Page 25: ...tasks have been grouped by time intervals in a series of tables Maintenance responsibilities of the user see on page 23 1 3 2 Maintenance responsibilities of the user Like any other machine the HVAC...

Page 26: ...ts They should also be aware of general procedures and those applying specifically to this unit Contact a Johnson Controls Inc Authorised Technical Assistance Service for scheduled maintenance on this...

Reviews: