SECTION XII: START UP SHEET

Heat Pump and Supplementary Heat Start-Up Sheet 

 Proper start-up is critical to customer comfort and equipment longevity

  

 

  

  

  
  
  
  
  

  

  
  
  
  
  

  

  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

  

  
  
  
  
  
  
  
  
 

Name

Address

City

State or Province

Zip or Postal Code

Indoor Unit Model #

Indoor Unit Serial #

Indoor Coil Model #

Indoor Coil Serial #

Upflow

Downflow

Horizontal Left

Horizontal Right

Unit is level

Venting system properly sized, within the limitations of the charts in the installation instructions.

Condensate drain for indoor coil properly connected

Filter Type

Intake Size

Exhaust Size

# of 90 Degree Ells

# 0f 45 Degree Ells

Length 

Length 

# 0f 45 Degree Ells

# of 90 Degree Ells

Polarity is correct (120vac indoor units) black is L1 (hot), white is N (neutral)

Ground wire is connected

Indoor unit (volts AC)

Low voltage values: "R" and "C" at Indoor unit control board (volts AC)

Thermostat Type

Other System Equipment and Accessories

Owner Information

Equipment Data

Venting (if applicable)

Electrical: Line Voltage

 

Outdoor Unit Model #

Outdoor Unit Serial #

Filter, Thermostat, Accessories

Filter Location(s)

Connections -- Per Installation Instructions and Local Codes 

Gas piping is connected (if applicable)

Supply plenum and return ducts are connected and sealed

Filter Size

Vent system is connected (if applicable)

Thermostat wiring complete

Heat anticipator is set to the recommended value listed in the Installation Instructions

Electrical: Low Voltage

 

Technician Performing Start-Up

Installing Contractor Name

Start-Up Date

Condensate drain for furnace (if applicable) 

Refrigerant piping complete and leak tested

Outdoor unit (volts AC)

Overcurrent Protection Breaker / Fuses Amperes

"R" and "C" Outdoor unit control board (volts AC)

Supplementary Heating Set-Up

 

Natural Gas

LP Gas (Requires LP Conversion Kit)

Electric Air Handler

LP Gas Conversion Kit Part # Used

LP Kit Installed By

Inlet Gas Pressure (in. w.c.")

Calculated input in btuh - clock the gas meter (Nat Gas Only) 

Manifold Gas Pressure (in. w.c.")

Heating Type

Heat anticipator  

recommended value

Electric Heat Kit Part # (if applicable)

KW installed

 

Continued on next Page 

Rated BTU/H (furnaces)

Print Form

Reset Form

Summary of Contents for YHJF60

Page 1: ...al line lengths Refer to Appli cation Data covering General Piping Recommendations and Refriger ant Line Length Part Number 247077 SECTION II SAFETY This is a safety alert symbol When you see this sym...

Page 2: ...er of hot air into the outdoor unit Provide adequate structural support ADD ON REPLACEMENT RETROFIT When this unit is being used as a replacement for an R 22 unit it is required that the outdoor unit...

Page 3: ...eet The charge given is applicable for total tubing lengths up to 15 feet See Application Data Part Number 247077 for installing tubing of longer lengths and elevation differences PRECAUTIONS DURING L...

Page 4: ...er grommet from the vapor connection at the indoor coil Braze the vapor line to the evaporator vapor connection After the connection has cooled place the rubber grommet back into the mounting position...

Page 5: ...al 1 3 turn to seal 8 Install the TXV bulb to the suction line near the equalizer line using the bulb clamp s furnished with the TXV assembly kit Ensure the bulb is making maximum contact a Install th...

Page 6: ...coil adjustment if any from Tabular Data Sheet 3 Calculate the additional charge for refrigerant piping using the Tabu lar Data Sheet if line length is greater than 15 feet 4 6 m 4 Total system charge...

Page 7: ...itches and over current protection must be supplied by the installer Wire size should be sized per NEC requirements The complete connection diagram and schematic wiring label is located on the inside...

Page 8: ...he recommended air flow settings for each size condensing unit Set the cooling speed per the instructions for the air handler or furnace by selecting the correct COOL and ADJUST or ADJ taps Verify the...

Page 9: ...4 Volt Hot W3 Third Stage Heat COM 24 Volt Common R 24 Volt Hot W1 First Stage Aux Heat W2 Second Stage Aux Heat Y1 Single Stage Compressor Y Y2 Second or Full Stage Compressor O Reversing Valve Energ...

Page 10: ...uxiliary Heat COM 24 Volt Common R 24 Volt Hot W1 First Stage Aux Heat W2 Second Stage Aux Heat Y1 Single Stage Compressor Y Y2 Second or Full Stage Compressor O Reversing Valve Energized in Cool X L...

Page 11: ...energized only when the unit is not running If the main switch is disconnected for long peri ods of shut down do not attempt to start the unit until 8 hours after the switch has been connected This wi...

Page 12: ...GRN GREEN GRY GREY ORG ORANGE PUR PURPLE RED RED WHT WHITE YEL YELLOW Y B YEL BLK LEGEND AS AMBIENT SENSOR CAP CAPACITOR COMP COMPRESSOR CC CONTACTOR COIL CCH CRANKCASE HEATER DS DISCHARGE SENSOR HPS...

Page 13: ...plicable Electrical Line Voltage Outdoor Unit Model Outdoor Unit Serial Filter Thermostat Accessories Filter Location s Connections Per Installation Instructions and Local Codes Gas piping is connecte...

Page 14: ...p Cut Out Balance Point Defrost Curve Y2 Lock FFUEL Switch Point Hot Heat Pump Fill in the information ie ON OFF or the appropriate Value for the fields that apply to the defrost control board install...

Page 15: ...plain operation of system to equipment owner Explain the importance of regular filter replacement and equipment maintenance Owner Education Provide owner with the owner s manual Explain thermostat use...

Page 16: ...change without notice Published in U S A 835959 UIM D 0814 Copyright 2014 by Johnson Controls Inc All rights reserved Supersedes 835959 UIM C 0614 York International Corp 5005 York Drive Norman OK 73...

Reviews: