Operation Manual

 Special remarks 

 Troubleshooting

If overflow of drain water from the indoor unit occurs, stop the operation and contact your contractor.

If you smell or see white smoke coming from the unit, turn OFF the main power supply and contact
your 

installer.

1.

 

If the trouble still remains even after checking the following, contact your installer and inform them 

   of the following items

.

      (1) Unit Model Name
      (2) Content of Trouble

 2.

 

No Operation

      Check whether the SET TEMP is set at the correct temperature.

       

     

CAUTION

6

 A

3 minutes protection after compressor stop

    To protect compressor, it will be continue off for at least 3 minutes once it has stopped.

5 minutes protection

Cooling operation

Heating operation

nti-freezing function during cooling

When the temperature of the air from the indoor outlet is too low, the unit will run for some time under the 

    fan mode, to avoid frost or ice forming in the indoor heat exchanger.

Cold air prevention

Defrosting

Compressor

 

must

 

run

 

5

 

minutes

 

at

 

least

 

once

 

start

 

running

In

 

the

 

5

 

minutes

compressor

 

will

 

not

 

stop

 

even

  

the

 

room temperature

 

reaches

 

the

 

set

 

point

 

unless

 

you

 

use

 

remote

 

control

 

switch

 

to

 

turn

 

off

 

the

 

unit

 (

all

 

 

indoor

 

unit

 

can

 

be turned

 

off

 

by

 

user

).

The

 

fan

 

of

 

the

 

indoor

 

unit

 

will

 

never

 

stop

 

running

 

in

 

cooling

 

operation

It

 

remains

 

running

 

even

 

if

 

the

 

compressor

 

 stops

 

working

.

Heating

 

capacity

 

depends

 

on

 

external

 

factors

 

as

 

outdoor

 

unit

 

temperature

Heating

 

capacity

 

might

 

decrease

  

if outdoor

 

ambient

 

temperature

 

is

 

too

 

low

In

 

several

 

minutes

 

after

 

the

 

heating

 

mode

 

is

 

started

the

 

fan

 

of

 

the

 

indoor

 

unit

 

will

 

not

 

run

 

until

 

the

 

heat

 

exchanger

 

of

 

the

 

indoor

 

unit

 

reaches

 

a

 

certain

 

temperature

 

in

 

order

 

to

 

prevent

 

cold

 

draft

.

When

 

the

 

outdoor

 

temperature

 

is

 

too

 

low

frost

 

or

 

ice

 

may

 

form

 

in

 

the

 

outdoor

 

heat

 

exchanger

reducing

     

heating

 

performance

When

 

this

 

happens

a

 

defrosting

 

system

 

of

 

the

 

air

 

conditioner

 

will

 

operate

At

 

the

 

same

 

time

 

the

 

fan

 

in

 

the

 

indoor

 

unit

 

stops

 (

or

 

runs

 

at

 

a

 

very

 

low

 

speed

 

in

 

some

 

cases

), 

to

 

prevent

 

cold

 

draft

After

 

defrosting

 

is

 

over

the

 

heating

 

operation

 

and

 

fan

 

speed

 

restart

.

Auto

 

re

-

start

 

from

 

Power

 

Break

When

 

the

 

power

 

supply

 

is

 

recovered

 

after

 

power

 

break

all

 

preset

 

are

 

still

 

effective

 

and

 

the

 

air

-

conditioner

 

    Purging of residue heated air

 

  When stop the air conditioner in normal operation, the fan motor would run with low speed for a while to 

    blow out the residue heated air.

will

 

 run

 

according

 

to

 

the

 

previous

 

setting

.

AUV-18HR4SSA1
AUV-24HR4SFA1
AUV-36HR6SDB1
AUV-48HR6SEC1
AUV-60HR6SPC1

RPFC-2.0UNZ1NH
RPFC-3.0UNZ1NH
RPFC-4.0UNZ1NH
RPFC-6.0UNZ1NH
RPFC-6.5UNZ1NH

YFGN18BZNRZUH1
YFGN24BZNRZUH1
YFGN36BZMRZUH1
YFGN48BZMRZUH1
YFGN55BZMRZUH1

RAS-2.0UNZGNH1
RAS-3.0UNZGNH1
RAS-4.0UNZGMH1
RAS-6.0UNZGMH1
RAS-6.5UNZGMH1

Blowing out the surviwal heating air

When

 

stoping

 

the

 

air

 

conditioner

 

in

 

normal

 

operation

the

 

fan

 

motor

 

would

 

run

 

with

 

low

 

speed

 

for

 

a

 

while

 

to

 

blow

     

out

 

the

 

residual

 

heating

 

air

.

Summary of Contents for YFGN24BZNRZUH1

Page 1: ...ir Conditioner R 410A 50Hz T1 Heat Pump R 410A 50Hz T1 Cooling Only Model YFGN18BZNRZUH1 YFGN24BZNRZUH1 YFGN36BZMRZUH1 YFGN48BZMRZUH1 YFGN55BZMRZUH1 Model YFFN18BZNRZTH1 YFFN24BZNRZTH1 YFFN36BZMRZTH1...

Page 2: ...t Tubing 15 4 1 The Tubing Material 15 4 2 Tubing Connection 15 16 5 Drain Tubing 6 Electrical wiring 17 7 Attaching the Air Return Grille 17 8 The Installation of the Outdoor Unit 18 8 18 1 Installat...

Page 3: ...rature 25 60 Humidity 30 80 Heating and electric heating function are not available for cooling only models The symbol refers to a hazard which can result in severe personal injury or death The symbol...

Page 4: ...duct is installed is supposed to have the independent leakage protective device and the electric current over load protection device which are provided for this product If not it will caus an eleectri...

Page 5: ...ribed in this instruction manual Never use gasoline or other inflammable gas near the air conditioner which will cause fire hazards When the air conditioner operation is abnormal such as burnt smell d...

Page 6: ...ontal Louver 4 Composition of the Air conditioner Indoor Unit Outdoor Unit 48K 55K 18K 24K 36K Notes Figures in the manual are only simple representation of the appliance it may not comply with the ap...

Page 7: ...roller or wireless remote controller It is used for power ON OFF setting the operating mode temperature fan speed and other functions There are different types of remote controllers which can be used...

Page 8: ...nless you use remote control switch to turn off the unit all indoor unit can be turned off by user The fan of the indoor unit will never stop running in cooling operation It remains running even if th...

Page 9: ...long period of time Clean the air filter and panels or allow a good ventilation Sound from Deforming Parts Steam from Outdoor Heat Exchanger When the cooling operation continues for a long period of...

Page 10: ...nit Terminal Terminal SI L N SI L N Power connecting cord N R S T 36K 48K 55K Outdoor unit Indoor unit Terminal Terminal N N 1L 3L 2L 1L 3L 2L Power connecting cord N L 18K 24K Gas piping Wide service...

Page 11: ...es other than the specified refrigerant R410A such as air Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture resulting in injury If a...

Page 12: ...8 9 10 11 12 13 14 Tool Knife or wire stripper Gradienter Hammer Churn drill Tube expander Inner hexagon spanner Tape measure 3 1 Before installation When moving the unit during or after unpacking ma...

Page 13: ...t Piping Connection For Drain Tube Connection For Joint Socket Connection For Drain Hose Connection For Drain Hose Cover 1 1 1 1 2 2 1 10 8 1 For Drain Hose Connection 1 For Drain Hose And Piping Conn...

Page 14: ...more than 6 m to avoid malfunction due to cross communication The air path is not blocked Condensate can drain properly The ceiling is strong enough to bear the weight of the indoor unit Sufficient c...

Page 15: ...outlet Right outlet Rear outlet Drain outlet rear right Drain outlet rear left Drain outlet right Drain outlet left Fig 3 3 3 Fig 3 3 4 Fig 3 3 5 1 Remove the air return grille Slide stoppers 4 place...

Page 16: ...wo screws M5 1 each on the left and right sides Floor standing type installation 1 Select the suspension bolt locations and the tube hole location Use enclosed paper pattern as a reference and drill t...

Page 17: ...outed through the back Cut the removed top cover and install to the rear panel instead of rear cover Gas piping Liquid piping Drain piping right Drain piping left Use the R410A refrigerant When carryi...

Page 18: ...eas below should be insulated because condensation may form there causing water to leak Drain ing passing indoors tub Drain sockets Referring the figure below insulate the drain socket and drain hose...

Page 19: ...grille When clamping the wiring use the included clamping material as shown in the Fig 6 1 to prevent outside pressure being exerted on the wiring connections and clamp firmly When doing the wiring m...

Page 20: ...ew at least 4 About 40cm About 10cm Indoor unit Tube length L Height difference H Outdoor unit 20 m 15 m 15 g m 30 m 15 m 35 g m 30 m 20 m 35 g m 50 m 30 m 35 g m Max Tube length L Model 24K 36K 48K 5...

Page 21: ...eat insulation effect Also be sure the condensed drain hose splits away from bundle and drips clear of the unit and the tubing The two refrigerant tubes and electrical wire if local codes permit shoul...

Page 22: ...se contact local technical service center of our company for further information Narrow tube Hex wrench Wide tube Service valve Bonnet of service valve Bonnet of narrow valve Bonnet of wide valve Indo...

Page 23: ...ard EN60335 1 Use the wires which are not lighter than the ordinary polychloroprene sheathed flexible cord code designation H07RN F When connecting the terminal block using flexible cord make sure to...

Page 24: ...nt possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use...

Reviews: