JOHNSON CONTROLS
48
FORM 201.23-EG2 (713)
CO
NT
RO
L P
ANE
L
L1
L2
R6
R1
L6
L5
L4
L3
R2
R3
R4
R5
R7
L7
x
y
Isolator Locations
STANDARD EFFICIENCY - SI
MODEL YCIV
ISOLATOR LOCATIONS ( X , Y ) - MM AND POINT LOADS - KG
50 HZ
1
2
3
4
5
6
7
0600S/P
LEFT - L
( 230 , 2204 ) ( 1510 , 2204 ) ( 2780 , 2204 ) ( 5360 , 2204 )
AL FIN COILS
772
722
633
608
CU FIN COILS
772
773
789
763
RS&LS1 / AL FIN COILS
853
803
633
608
RS&LS1 / CU FIN COILS
853
854
789
763
RIGHT - R
( 230 , 32 )
( 1510 , 32 )
( 2780 , 32 )
( 5360 , 32 )
AL FIN COILS
772
722
633
608
CU FIN COILS
772
773
789
763
RS&LS1 / AL FIN COILS
853
803
633
608
RS&LS1 / CU FIN COILS
853
854
789
763
0650S/P
LEFT - L
( 230 , 2204 ) ( 1510 , 2204 ) ( 2780 , 2204 ) ( 5360 , 2204 )
AL FIN COILS
780
732
756
730
CU FIN COILS
780
783
912
885
RS&LS1 / AL FIN COILS
861
813
756
730
RS&LS1 / CU FIN COILS
861
864
912
885
RIGHT - R
( 230 , 32 )
( 1510 , 32 )
( 2780 , 32 )
( 5360 , 32 )
AL FIN COILS
772
723
756
730
CU FIN COILS
772
774
912
885
RS&LS1 / AL FIN COILS
853
804
756
730
RS&LS1 / CU FIN COILS
853
855
912
885
0720S/P
LEFT - L
( 230 , 2204 ) ( 1510 , 2204 ) ( 2780 , 2204 ) ( 4970 , 2204 ) ( 6740 , 2204 )
AL FIN COILS
778
716
707
578
351
CU FIN COILS
778
771
861
750
424
RS&LS1 / AL FIN COILS
859
797
707
578
351
RS&LS1 / CU FIN COILS
859
852
861
750
424
RIGHT - R
( 230 , 32 )
( 1510 , 32 )
( 2780 , 32 )
( 4970 , 32 )
( 6740 , 32 )
AL FIN COILS
770
707
707
563
301
CU FIN COILS
770
762
861
735
374
RS&LS1 / AL FIN COILS
851
788
707
563
301
RS&LS1 / CU FIN COILS
851
843
861
735
374
0770S/P
LEFT - L
( 230 , 2204 ) ( 1510 , 2204 ) ( 2780 , 2204 ) ( 4970 , 2204 ) ( 6740 , 2204 )
AL FIN COILS
784
762
802
686
415
CU FIN COILS
784
817
956
858
488
RS&LS1 / AL FIN COILS
865
843
802
686
415
RS&LS1 / CU FIN COILS
865
898
956
858
488
RIGHT - R
( 230 , 32 )
( 1510 , 32 )
( 2780 , 32 )
( 4970 , 32 )
( 6740 , 32 )
AL FIN COILS
784
760
800
669
363
CU FIN COILS
784
815
956
841
436
RS&LS1 / AL FIN COILS
865
841
800
669
363
RS&LS1 / CU FIN COILS
865
896
954
841
436
0840S/P
LEFT - L
( 230 , 2204 ) ( 1510 , 2204 ) ( 2780 , 2204 ) ( 4970 , 2204 ) ( 6740 , 2204 )
AL FIN COILS
784
762
802
691
435
CU FIN COILS
784
817
956
863
508
RS&LS1 / AL FIN COILS
865
843
802
691
435
RS&LS1 / CU FIN COILS
865
898
956
863
508
RIGHT - R
( 230 , 32 )
( 1510 , 32 )
( 2780 , 32 )
( 4970 , 32 )
( 6740 , 32 )
AL FIN COILS
784
760
800
689
433
CU FIN COILS
784
815
954
861
506
RS&LS1 / AL FIN COILS
865
841
800
689
433
RS&LS1 / CU FIN COILS
865
896
954
861
506
Summary of Contents for YCIV
Page 27: ...JOHNSON CONTROLS FORM 201 23 EG2 713 27...
Page 29: ...JOHNSON CONTROLS FORM 201 23 EG2 713 29...
Page 31: ...JOHNSON CONTROLS FORM 201 23 EG2 713 31...
Page 33: ...JOHNSON CONTROLS FORM 201 23 EG2 713 33...
Page 35: ...JOHNSON CONTROLS FORM 201 23 EG2 713 35...
Page 37: ...JOHNSON CONTROLS FORM 201 23 EG2 713 37...
Page 39: ...JOHNSON CONTROLS FORM 201 23 EG2 713 39...
Page 41: ...JOHNSON CONTROLS FORM 201 23 EG2 713 41...
Page 43: ...JOHNSON CONTROLS FORM 201 23 EG2 713 43...
Page 45: ...JOHNSON CONTROLS FORM 201 23 EG2 713 45...
Page 47: ...JOHNSON CONTROLS FORM 201 23 EG2 713 47...
Page 55: ...JOHNSON CONTROLS FORM 201 23 EG2 713 55 INTENTIONALLY LEFT BLANK...
Page 68: ...JOHNSON CONTROLS 68 FORM 201 23 EG2 713 Typical Control Wiring Two Compressor...
Page 70: ...JOHNSON CONTROLS 70 FORM 201 23 EG2 713 Typical Control Wiring Three Compressor...
Page 72: ...JOHNSON CONTROLS 72 FORM 201 23 EG2 713 Typical Control Wiring Four Compressor...