37
Heat of Extraction/Rejection Data - Dual Capacity Units
Model
GPM
Heat of Extraction (kBtuh)
Heat of Rejection (kBtuh)
30°F
50°F
70°F
90°F
30°F
50°F
70°F
90°F
110°F
026
Part Load
3.0
13.1
17.6
21.5
23.5
22.9
21.8
5.0
9.4
13.8
18.6
22.6
21.7
23.6
23.0
21.7
20.2
7.0
9.6
14.1
18.9
23.0
21.9
23.7
23.1
21.7
20.2
Full Load
4.0
17.8
23.4
28.5
31.0
31.2
30.0
6.0
13.4
18.8
24.7
29.9
29.9
31.1
31.3
29.9
28.1
8.0
13.6
19.3
25.1
30.5
30.1
31.2
31.3
29.9
28.1
038
Part Load
4.0
17.9
23.3
28.1
32.5
31.8
30.0
6.0
12.8
18.7
24.5
29.8
29.8
32.7
32.0
30.1
28.2
8.0
13.9
19.7
25.2
29.8
30.3
33.1
32.4
30.4
28.5
Full Load
5.0
25.1
31..5
36.1
44.8
45.1
42.8
7.0
18.7
26.2
33.2
38.6
41.8
45.2
45.7
43.6
41.0
9.0
19.1
26.9
34.3
40.0
42.0
45.5
46.0
43.8
41.1
049
Part Load
5.0
24.0
29.5
33.7
44.9
46.1
44.0
8.0
19.2
26.4
32.6
37.5
40.6
45.0
45.8
43.4
40.5
11.0
19.8
27.5
34.3
39.9
40.0
44.9
46.1
44.3
41.5
Full Load
6.0
33.3
40.6
46.1
60.2
60.2
56.4
9.0
26.0
34.7
42.8
49.1
56.0
60.2
60.8
57.4
52.9
12.0
26.5
35.7
44.2
50.9
56.1
60.4
61.1
57.6
53.2
064
Part Load
6.0
31.0
39.2
46.1
56.3
55.4
52.1
10.0
21.6
31.4
40.9
49.7
52.4
56.2
55.5
52.4
49.4
14.0
22.6
32.6
41.7
49.8
52.2
56.2
55.6
52.6
49.7
Full Load
8.0
40.8
52.7
64.7
73.7
75.7
70.3
12.0
31.9
43.8
55.1
65.8
66.8
74.1
76.1
70.5
66.2
16.0
32.2
44.7
56.8
68.6
67.2
74.5
76.5
70.9
66.3
072
Part Load
10.0
36.4
46.5
54.7
63.4
63.0
58.9
13.0
25.2
36.7
48.5
59.1
57.7
63.2
63.0
59.2
55.1
16.0
26.7
38.2
49.4
59.1
57.3
63.2
63.3
59.5
55.4
Full Load
12.0
48.3
62.7
69.0
81.8
83.0
77.8
15.0
37.2
51.6
65.4
70.9
73.6
82.1
83.3
78.0
71.9
18.0
37.6
52.7
67.5
73.5
74.1
82.6
83.8
78.4
72.2
Note: operation not recommended in shaded areas.