Wiring Schematics cont.
Aurora Base with ECM, IntelliStart and UPC
Transformer
24V
ECM
Blower
Motor
P12
P11
2
3
4
5
1
Green(107)
16 1
12 15 10
PW
M
C1
C2
R
G
33
CF
M
To P2 on
Electric Heat
Board
RV
CC
HP
Condensate
Blac
k(125
)
Blac
k(124
)
Blue(
123
)
Blue
(122
)
LP
T
Ye
llo
w
(11
7)
Ye
llo
w
(11
6)
FP1
Orange
(121
)
O
range
(120
)
RV
Black(15)
Violet(14)
Green(11)
Brown(115)
NOTE 1
Violet(111)
Blue(110)
Yellow(109)
Green/Yellow(108)
Black/White
Yellow
Red
208V
1
C
2
4
3
2
Black(113)
Black(114)
Black(112)
PB2
1
3
2
Brown(106)
Orange(105)
Blue
240V
Black
UltraTech
Dual Capacity
Units Only
RCP
CS
Blue(16)
Blue(18)
CC
T2
T1
Compressor
C
R
S
Blue
G
L1
L2
208-230/60/1
Unit Power Supply
Violet(7)
Tan(6)
Black(3)
Black(2)
Cap
Ext Pump
1/2 hp Total
208-230/60/1
Pump
G
1
2
PB1
1
2
Pump
Violet(8)
NOTE 2
Gray/White(4)
Event
Normal Mode
Test Mode
Random Start Delay
Compressor On Delay
Compressor Minimum On Time
Compressor Short Cycle Delay
Blower Off Delay
Fault Recognition Delay – High Pressure
Start-Up Bypass – Low Pressure
Fault Recognition Delay – Low Pressure
Start-Up Bypass – Low Water Coil Limit
Fault Recognition Delay – Low Water Coil Limit
Fault Recognition Delay – Condensate Overflow
Thermostat Call Recognition Time
Comfort Alert Recognition Time
Auxiliary Heat Staging Delay
Emergency Heat Staging Delay
Water Valve Slow Open Delay
Less than 1 second
5 to 80 seconds
1 second
5 seconds
< 1 second
30 seconds
2 seconds
Less than 1 second
2 minutes
5 seconds
4 minutes
15 seconds
2 minutes
2 minutes
30 seconds
30 seconds
30 seconds
30 seconds
30 seconds
30 seconds
30 seconds
30 seconds
2 seconds
2 seconds
90 seconds
90 seconds
90 seconds
90 seconds
5 minutes
2 minutes
20 seconds
7.5 seconds
Aurora Timing Events
Black/White(5)
Circuit Breaker
Circuit Breaker
Optional Internal
Hot Water Generation P ump
1
5A
5A
DHW
Pump
Blue
Hot Water
Limit Switch
130°F
Blue
1
2
3
Purple
Cabinet
HW Switch
Run Winding
Active
Start
Common
IntelliStart
Red
Pink
Black
Blue
NOTE 6
CC2
Fa
ct
ory
Fault
AL
G
AL
M
LS
ES
ACC c
Status
AURORA BASE
CONTROL™
RV – K1
CC
2
CC – K2
CC Hi – K3
Fan – K4
Alarm – K5
Acc – K6
ACC n
o
ACC n
c
O/
B
C
R
LO
G
Y1
Y2
W
DH
3A-
Fu
se
O/
B
C
R
LO
G
Y1
Y2
W
DH
LO
G
HI
CCG
CC
FG
F
R
HP
HP
LP
FP2
FP2
FP1
REV
REV
CF
M
PW
M
ECM PWM
Fa
ct
ory
Factory Fan Connection
R
R
CC
C
RS
485
EH2
C
EH1
C
CO
(+)
(-)
R
C
R
S485 E
xp
Fa
ct
ory
Com1
Com2
Config
G
G
G
Y
R
SW1 Test
FP1 – 15
o
F/30
o
F
JW2 - Alarm
P11
P5
P2
P1
P8
P7
P9
P6
P3
SW2
P13
P4
FP2 – 15
o
F/30
o
F
RV – B/O
ACC – Dip 4
ACC – Dip 5
CC – Dual/Single
L – Pulse/Continuous
Reheat/Normal
Fa
ct
ory
U
se
Field Connections
Field Connections
C
LP
FP1
F
CC
G
Y1
1
2
3
4
5
6
7
8
Off
On
N/A
RS
485 N
ET
EH1
LED1
LED2
LED3
S
C
Fa
S
Fa
Fl
N
In
H
Lo
Fu
Fr
R
C
O
Fu
Fu
FP
T
Bl
ac
k(
11
8)
FP2
Bl
ac
k(
11
9)
CFM
P13
P4
SW1
P5
JW
2
P9
LO
O/B
Y2
W
DH
P8
P7
RS485 NET
RS485 NET
P6
RS485 EXP
P3
SW2
On
Future Use
L Output Type
CC – Dual/Single
Acc – Dip 5
Acc – Dip 4
RV – B/O
FP2 – 15
°F/30°F
FP1 – 15
°F/30°F
Com1
LED5
Com2
LED5
Test Mode
F1-3A
P1
C
PWM
1
2
3
4
5
6
7
8
ALM
ALG
ACC COM
ACC NO
ACC NC
R
C
G
Y1
EH2
C
EH1
C
CO
C R
-
+
C R
-
+
Off
Fault
LED1
R
Status
LED3
Config
LED2
CC2
CC
F
C
R
F FG CC CCGCC2
HI
CC2
LO
CC2
G
REVREVFP1 FP1 FP2 FP2 LPS LPSHPSHPS
Aurora Base Control
(ABC)
K1-
RV
R
ela
y
K2
-CC Re
lay
K3-
C
C2
Rel
ay
K4
-Fan R
ela
y
K5-Alarm
Relay
K6-Acc
Relay
F
R
C
CC
G
Y1
C
R
ES
LS
P2
EH1
Y
G
G
G
LED4
LED5
Water Solenoid
(see Open Loop
Groundwater Systems
section)
4 - When installed the Auxiliary Heat powers blower and controls.
3 - Use manufacturer’s part number 19P592-01 (jumper bar assembly)
when single source power is required.
1 - Switch blue and red wires for 208V operation.
2 - The blk/wh and gray/wh wires are removed when Aux Heat is installed
6 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower.
7 - Field installed SPST relay required for dual fuel installation.
Notes
Communicating Thermostat
Dual Fuel Wiring Diagram
Using Field Installed Relay
24 VDC
R f rom Foss il
Fue l Furnac e
To Foss il Fuel
Furnac e W input
EH1
C
ABC
Board
Note 7: Fiel d i ns ta lled SPST dua l f ue l rel ay
(Re quired f or dual f uel i ns ta llat ion)
Traditional Thermostat
Dual Fuel Wiring Diagram
Using Field Installed Relay
Y1
Y2
O
R
C
L
C
R
Fos sil Fue l
Furnac e
The rmost at
24 VAC
Common
Common
24 VAC
Fault Signa l
Re vers ing Va lve
2nd St age Compres sor
1st Sta ge Compre ss or
Y1
Y2
O
R
C
LO
ABC Board
G
G
Fan
W
W
Auxil iary Hea t R ela y
Note 7: Fiel d i ns ta lled SPST dua l f ue l rel ay
(Re quired f or dual f uel i ns ta llat ion)
Auxil iary Hea t R ela y
P2
P1
Auxil iary
He at Rela y
ES
= cha ssis
5 – Low voltage wiring CLASS 2.
Green/Yellow
UPC Controller
ZS Sensor
Affinity & Affinity Advanced Series
1 - 6 Tons 60Hz
SD2500AK6 11/22
52