Contractor:
P.O.:
Engineer:
Project Name:
Unit Tag:
The manufacturer works continually to improve its products. As a result, the design and speci
fi
cations of each product at the time of order may be changed without notice. Purchaser’s approval of this data set signi
fi
es that the equipment is acceptable under the provisions
of the job speci
fi
cation. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely the manufacturer’s opinion or commendation of its products. York and Af
fi
nity are registered
trademarks of Johnson Controls, Inc., and are used with permission.
Affinity & Affinity Advanced Series
1 - 6 Tons 60Hz
SD2500AK6 06/21
2
Page _____ of _____
Model Nomenclature - Af
fi
nity
Model Nomenclature - Af
fi
nity Advanced
YZF
T
038
T
L
1
4
1
C
A
0
D
*
1-3
4
4-6
8
9
10
11
12
13
14
15
16
17
Model
YZF
–
Affinity Advanced
Forced Air
Stage
T
–
Dual Capacity
Unit Capacity
026, 038, 049
064, 072
Discharge Configuration
T
–
Top (Vertical)
S
–
Side (Horizontal)
E
–
End (Horizontal)
B
–
Bottom (Vertical)
Air Configuration
L
–
Left
R
–
Right
Voltage
1 – 208
-
230/60/1
Hot Water Generation Option
0 –
No HWG, No IntelliStart
®
1 –
HWG with Factory Installed Pump,
No IntelliStart
1
3 –
No HWG, IntelliStart
1
4 –
HWG with Factory Installed Pump,
IntelliStart
1
Vintage
* –
Factory Use Only
Controls
D
–
Aurora Performance and
Refrigeration Package
Air Coil Option
0 –
Standard, Uncoated
Filter Options
A - 2" MERV 11 Filter
Water Coax Option
C
–
Copper
N
–
CuproNickel
Blower Option
1 –
Variable Speed ECM
4 –
5-Speed ECM
Rev.:
04/27/2021
Notes:
1 –
IntelliStart available 026-072
2 –
Symphony/AWL not available
YAF
T
038
T
L
1
4
1
C
A
0
A
*
1-3
4
4-6
8
9
10
11
12
13
14
15
16
17
Model
YAF
–
Affinity Forced Air
Stage
S
–
Single Speed (012, 018, 022,
030, 036, 042, 048, 060, 070)
T
–
Dual Capacity (026, 038, 049,
064, 072)
Unit Capacity
012, 018, 022, 026, 030, 036, 038,
042, 048, 049, 060 ,064, 070, 072
Discharge Configuration
T
–
Top (Vertical)
S
–
Side (Horizontal)
E
–
End (Horizontal)
B
–
Bottom (Vertical 022-072)
Air Configuration
L
–
Left
R
–
Right
Voltage
1 – 208
-
230/60/1
Hot Water Generation Option
0 –
No HWG, No IntelliStart
®
1 –
HWG with Factory Installed Pump,
No IntelliStart
1
3 –
No HWG, IntelliStart
4 –
HWG with Factory Installed Pump,
IntelliStart
1, 2
Vintage
* –
Factory Use Only
Controls
A
–
Aurora
TM
Base Control
Air Coil Option
0 –
Standard, Uncoated
Filter Options
A - 2" MERV 11 Filter
Water Coax Option
C
–
Copper
N
–
CuproNickel
Blower Option
0 - PSC ( 012 Only)
1 –
Variable Speed ECM (018-072)
4 –
5-Speed ECM (022-072)
Rev.:
04/27/21
Notes:
1 –
HWG available 018-072
2 –
IntelliStart available 022-072
3 –
Symphony/AWL not available