036-21021-003 Rev. C (0203)
4
Unitary Products Group
- = Not applicable
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
ELECTRIC
2
HEAT. KW
W
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
3
EER
TOTAL
SENS.
1 PH 11 SEER AC / N1VS - VARIABLE SPEED
H4DE024S06
N1AHB0806
2,5,8,10
17
G2FD024(S,H)17
850
23.0
17.0
11.00
-
9.85
H4DE030S06
N1AHB1206
5,8,10,15,19
17
G2FD036(S,H)17
1015
28.6
21.5
11.20
-
10.10
N1AHB1206
5,8,10,15,19
17
G2FD046(S,H)17
1015
29.0
21.8
-
12.00
10.30
H4DE036S06
N1AHB1206
5,8,10,15,19
17
G2FD036(S,H)17
1225
35.0
26.3
11.10
-
9.80
N1AHB1206
5,8,10,15,19
17
G2FD046(S,H)17
1225
35.4
26.6
11.30
12.00
10.10
H4DE042S06
N1AHC1606
5,8,10,15,20
21
G2FD042(S,H)21
1400
40.0
30.0
11.10
-
9.90
N1AHC1606
5,8,10,15,20
21
G2FD048(S,H)21
1400
40.5
30.4
11.00
-
10.00
H4DE048S06
N1AHC1606
5,8,10,15,20
21
G2FD048(S,H)21
1650
48.5
35.9
11.00
-
9.85
N1AHD2006 8,10,15,20,25,30
24
G2FD048(S,H)24
1650
48.5
35.9
11.00
-
9.85
N1AHD2006 8,10,15,20,25,30
24
G2FD060(S,H)24
1350
48.5
35.9
11.20
11.60
10.20
H4DE060S06
N1AHD2006 8,10,15,20,25,30
24
G2FD060(S,H)24
1850
58.5
43.3
11.00
-
10.15
1 PH 11 SEER AC / N1VS - VARIABLE SPEED
H4DE024S06
N1VSB12
10,15,18
17
G2FD024(S,H)17
870
23.4
17.3
12.40
-
11.05
N1VSB12
10,15,18
17
G2FD036(S,H)17
870
24.2
17.9
12.60
-
11.25
H4DE030S06
N1VSB12
10,15,18
17
G2FD036(S,H)17
1000
29.2
21.9
12.10
-
11.00
N1VSB12
10,15,18
17
G2FD046(S,H)17
1015
29.4
22.1
12.75
-
10.80
H4DE036S06
N1VSB12
10,15,18
17
G2FD036(S,H)17
1225
34.4
25.8
11.60
-
10.20
N1VSB12
10,15,18
17
G2FD046(S,H)17
1225
35.6
26.7
12.00
-
10.20
H4DE042S06
N1VSC16
10,15,18
21
G2FD048(S,H)21
1400
41.0
30.8
12.00
-
10.80
H4DE048S06
N1VSC16
10,15,18
21
G2FD048(S,H)21
1670
49.0
36.3
11.40
-
10.15
N1VSD20
10,15,18,30
24
G2FD060(S,H)24
1675
51.0
37.7
12.60
-
11.30
H4DE060S06
N1VSD20
10,15,18,30
24
G2FD060(S,H)24
1600
58.0
42.9
11.50
-
10.50
1 PH 11 SEER AC / F2RP / RC / FP / FC / FV
4,5
H4DE024S06
F2RC/FC024
5,8,10
18
-
800
23.4
17.3
11.00
-
9.80
F2RC/FC030
5,8,10,15
18
-
800
23.4
17.3
11.00
-
9.85
F2RP/FP024
5,8,10
18
-
800
23.8
17.6
11.10
-
9.90
F2RP/FP030
5,8,10,15
18
-
830
24.2
17.9
11.25
11.50
10.05
H4DE030S06
F2RC/FC030
5,8,10,15
18
-
1015
28.2
21.2
11.00
-
10.10
F2RP/FP030
5,8,10,15
18
-
1015
28.6
21.5
11.10
11.50
10.10
F2RP/FP036
5,8,10,15,19
21
-
1015
29.0
21.8
11.50
11.70
10.70
H4DE036S06
F2RC/FC036
5,8,10,15
21
-
1225
33.8
25.4
11.00
-
9.80
F2RP/FP036
5,8,10,15,19
21
-
1225
35.2
26.4
11.50
11.50
10.10
H4DE042S06
F2RP/FP042
5,8,10,15
21
-
1400
39.5
29.6
-
11.00
10.10
F2FP048
5,8,10,15,20,25
24
-
1400
41.0
30.8
11.00
-
10.00
H4DE048S06
F2FP048
5,8,10,15,20,25
24
-
1625
48.0
35.5
11.00
-
9.50
F2FP060
5,8,10,15,20,25
24
-
1625
49.5
36.6
11.00
-
9.70
H4DE060S06
F2FP060
5,8,10,15,20,25
24
-
1830
57.5
42.6
11.00
11.15
9.60
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
0
°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
.
models. All ratings remain the same.
5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.