036-21021-003 Rev. C (0203)
16
Unitary Products Group
Multipliers for determining the performance with other indoor sections.
NOTE:
For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
H4DE060S06
INDOOR COIL MODEL NO.
G1FA060S21,24
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM
1700
1850
2000
ID DB
85
80
75
70
85
80
75
70
85
80
75
70
ID WB
72
67
62
57
72
67
62
57
72
67
62
57
75
T.C.
66.6
61.7
56.8
52.2
67.2
62.3
57.4
52.8
67.7
62.8
57.9
53.3
S.C.
41.6
42.0
42.7
43.0
42.9
43.3
44.1
44.5
44.2
44.7
45.5
45.9
K.W
4.75
4.67
4.59
4.51
4.82
4.74
4.66
4.58
4.88
4.80
4.72
4.64
85
T.C.
65.6
60.8
55.9
51.3
66.2
61.4
56.4
51.9
66.7
61.8
56.9
52.6
S.C.
41.9
42.2
42.9
43.2
43.4
43.7
44.4
44.8
44.8
45.2
45.9
46.6
K.W
5.23
5.14
5.06
4.97
5.30
5.22
5.13
5.05
5.36
5.28
5.19
5.11
95
T.C.
62.6
57.9
53.2
49.0
63.0
58.5
53.7
49.6
63.4
58.8
54.3
50.0
S.C.
41.2
41.5
42.1
42.8
42.7
43.3
43.9
44.4
44.3
44.6
45.7
46.0
K.W
5.81
5.73
5.64
5.55
5.88
5.80
5.71
5.63
5.94
5.86
5.78
5.69
105
T.C.
58.9
54.6
50.1
46.1
59.3
54.9
50.7
46.6
59.5
55.3
51.0
46.9
S.C.
40.1
40.4
41.0
41.3
41.7
42.0
43.0
43.2
43.3
43.7
44.3
44.5
K.W
6.46
6.38
6.30
6.21
6.56
6.45
6.36
6.28
6.60
6.51
6.43
6.35
115
T.C.
55.3
51.1
47.1
43.3
55.5
51.4
47.5
43.7
55.8
51.8
47.9
44.2
S.C.
39.0
38.9
39.8
40.1
40.4
40.6
41.4
41.6
42.1
42.4
43.2
43.4
K.W
7.20
7.13
7.04
6.95
7.28
7.20
7.11
7.02
7.34
7.25
7.16
7.09
125
T.C.
51.7
47.6
44.1
40.5
51.7
47.9
44.3
40.8
52.1
48.3
44.8
41.5
S.C.
37.9
37.4
38.6
38.9
39.1
39.2
39.8
40.0
40.9
41.1
42.1
42.3
K.W
7.94
7.88
7.78
7.69
8.00
7.95
7.86
7.76
8.08
7.99
7.89
7.83
NOTE:
ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
N1AHD2006
G2FD060(S,H)24
1.00
1.00
1.00
N1VSD20
G2FD060(S,H)24
0.99
0.99
0.95
F2FP060
0.98
0.98
1.03
G1HD060
1.00
1.00
1.02
G1UA060S21,24
1.00
1.00
1.00
G2FD060(S,H)24
1.00
1.00
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
P1DUC20V
G1FA060S21
1.01
1.01
1.00
P1DUC20V
G1UA060S21
1.01
1.01
1.00
P1XUC20V
G1FA060S21
1.01
1.01
1.00
P1XUC20V
G1UA060S21
1.01
1.01
1.00
P1XUD20V
G1FA060S24
1.01
1.01
1.00
P1XUD20V
G1UA060S24
1.01
1.01
1.00
P1XUD20V
G2FD060(S,H)24
1.01
1.01
1.00