background image

546039-YTG-C-0211

4

Unitary Products Group

amount of field labor. A field supplied and field installed 
electrical disconnect switch must be installed.

Round Duct Flanges 

 - (Factory Supplied - Field 

Installed) Equal size, side supply and return duct flanges 
allow easy hook-up of ducts.

Condensate Pan

 - A non-corrosive, long-lasting, water-

tight pan is positioned below the evaporator coil to collect 
and drain all condensate. Less collection of stagnate 
condensate will build-up. The condensate pan conforms 
to ASHRAE 62-89 standards (Ventilation for Acceptable 
Indoor Air Quality).

Condensate Drain

 - The 3/4 inch NPTF connection is 

rigidly mounted to assure proper fit and leak tight seal.

Durable Finish

 - With a heavy duty cabinet made of 

powder-painted, galvanized steel the neutral color blends 
into surrounding areas. The powdered paint provides a 
better paint to steel bond, which resists corrosion and rust 
creep. The glossy finish insures less fading when exposed 
to sunlight and offers a more attractive on site 
appearance. This paint finish meets ASTM-B117 
standards for 1000 hours salt spray rating, the highest in 
the industry.

Full Perimeter Base Rails

 - The base rails provide a 

solid foundation for the entire unit and protects the unit 
during shipment. The rails provide fork lift access from all 
sides. On applications where the unit is placed on a pad, 
the base will keep the unit off the pad to deter corrosion.

More Attractive Appearance

 - A single piece Water 

Shed top cover containing a top discharge condenser fan 
arrangement requires less square footage on installation 
and provides a wider variety of installations. The one 
piece design adds greater water integrity.

Top Discharge

 - The top discharge condenser fan does 

not disrupt neighboring areas or dry-out vegetation 
surrounding the unit. The warm air from the top mounted 
fan is blown up away from the structure and any 
landscaping. This allows compact location on multi-unit 
applications.

Condenser Coil Grille

 - All models utilize a decorative 

"Wire Form" coil guard to provide impact protection 
against large objects.

Low Operating Sound Level

 - The upward air flow 

carries the normal operating noise up and away from the 
living area. The rigid top panel effectively isolates any 
motor sound. Isolator mounted compressor and the 
rippled fins of the condenser coil muffle the normal fan 
motor and compressor operating sounds.

Fan System

 - 2, 2-1/2 and 3 Ton A/C models operate with 

a 3-speed PSC (Permanent Split Capacitor) fan motor. 4 
and 5 Ton A/C and all Heat Pump models operate with a 
constant torque (X Motor) fan motor with 5 speed taps. All 
these units easily match all types of applications and 
provide greater on site flexibility to match comfort 
requirements.

Protected Compressor

 - The compressor is internally 

protected against high pressure and temperature. This is 

accomplished by the simultaneous operation of high 
pressure relief valve and a temperature sensor which protect 
the compressor if undesirable operating conditions occur.

Pressure Switches 

- High pressure and low pressure/

loss of charge switches standard in all units. On Heat 
Pump models, when abnormal conditions are sensed 
through the pressure switches, the unit will lock-out 
preventing further operation until reset or the problem is 
corrected.

Exclusive Coil Design

 - Grooved copper tubes and 

enhanced aluminum fin construction on all indoor coils 
and heat pump outdoor coils improve heat transfer for 
maximum efficiency and durability or Micro-Channel 
aluminum tube, aluminum fin on all cooling outdoor coils 
for long lasting durability and efficient operation.

Low Maintenance

 - Long life, permanently lubricated 

condenser and evaporator fan motor bearings need no 
annual maintenance adding greater reliability to the unit.

Secured Service Access Ports

 - Protected, externally 

mounted, re-usable service access ports are provided on 
both the high and low lines for ease of evacuating and 
charging the system. No final field mounting required.

Easy Service Access

 - A large, single panel covers the 

electrical controls makes servicing easy. The blower 
compartment has a large panel which when removed will 
allow the blower fan assembly to slide-out for ease of  
maintenance and trouble shooting.

Replacement Parts

 - The installer requires no special 

training to replace any of the components of these units 
and does not need to maintain an inventory of unique 
parts.

Field Installed Accessories

Wall Thermostat

 - The units are designed to operate with 

24-volt electronic and electro-mechanical thermostats.

Electric Heat Kit

 - Available in 4 different kW capacities 

(5, 7, 10 and 15 kW). (Single phase only)

Start Assist Kits

 - Available for all models.

Outdoor Thermostat

 - Available for all heat pump models.

Guide Specifications

GENERAL

Units shall be factory-assembled, single packaged, Electric 
Cooling units, designed for outdoor mounted installation. Units 
shall have minimum SEER ratings of 13.0. Heat pump 7.7 HSPF.

The units shall be factory wired, piped, charged with R-410A 
refrigerant and factory tested prior to shipment. All unit wiring 
shall be color coded.

All units shall be manufactured in a facility certified to ISO 9001 
standards, and the cooling performance shall be rated in 
accordance with DOE and ARI test procedures. Units shall be 
certified to UL 1995/CAN/CSA C22.2 No. 236 standards.

Summary of Contents for R-410F

Page 1: ...air conditioners are designed for outdoor installation Only utility and duct connections are required at the point of installation Field installed electric heater accessories are available to provide...

Page 2: ...and Dimensions 49 Component Location Cooling Unit and Heat Pump Direct Drive Condenser Fan Motor High Efficiency Enhanced Copper Tube Aluminum Fin or Micro Channel Aluminum Tube Aluminum Fin Outdoor C...

Page 3: ...s Coil Technology All cooling units utilize Micro Channel all aluminum condensers which provide improved heat transfer capabilities and reduced charge volumes All evaporators utilize a conventional co...

Page 4: ...que X Motor fan motor with 5 speed taps All these units easily match all types of applications and provide greater on site flexibility to match comfort requirements Protected Compressor The compressor...

Page 5: ...n gas cooled and have a voltage range of or 10 of the unit nameplate voltage b Shall have internal isolation and sound muffling to minimize vibration and noise and be externally isolated on a dedicate...

Page 6: ...1 18 71 18 71 18 71 18 71 18 71 18 Circuitry Type 2 pass Microchannel 2 pass Microchannel 2 pass Microchannel 2 pass Microchannel 2 pass Microchannel 2 pass Microchannel EVAPORATOR COIL DATA Face area...

Page 7: ...roll Scroll Scroll Scroll Quantity 1 1 1 1 1 1 CONDENSER COIL DATA Face area Sq Ft 11 1 11 28 11 28 16 16 20 Rows 1 2 2 2 2 2 Fins per inch 20 15 20 15 15 20 Tube diameter in 3 8 3 8 3 8 3 8 3 8 3 8 C...

Page 8: ...Max F 024 2 0 NM UQ 208 230 1 60 187 252 125 030 2 5 NM UQ 208 230 1 60 187 252 125 036 3 0 NM UQ 208 230 1 60 187 252 125 208 230 3 60 187 252 125 042 3 5 NM UQ 208 230 1 60 187 252 125 048 4 0 NM UQ...

Page 9: ...1 12 6 1000 72 36 2 1 9 26 1 22 3 18 6 14 8 32 8 2 1 24 7 20 9 17 1 13 3 67 32 2 1 9 32 2 26 8 23 1 19 3 15 5 28 5 2 1 28 5 25 3 21 5 17 7 13 9 62 28 2 1 9 28 2 28 2 25 7 21 9 18 2 14 4 24 9 2 1 24 9...

Page 10: ...16 8 13 7 10 7 7 6 17 8 2 7 15 2 12 2 9 2 6 2 67 16 7 2 5 16 7 15 6 12 5 9 4 6 4 13 4 2 6 13 4 13 0 10 0 7 0 4 0 62 14 3 2 5 14 3 14 3 13 3 10 2 7 1 4 1 11 4 2 6 11 4 11 4 10 7 7 7 4 7 1 7 57 14 1 2 5...

Page 11: ...9 8 2 6 30 6 25 8 21 1 16 3 67 39 5 2 4 39 5 33 6 28 6 23 6 18 6 35 7 2 6 35 7 31 7 26 9 22 2 17 4 62 35 7 2 4 35 7 35 7 35 7 30 7 25 7 20 7 31 4 2 6 31 4 31 4 31 4 26 6 21 9 17 1 57 32 6 2 4 32 6 32...

Page 12: ...16 7 13 2 9 7 21 2 3 3 18 6 15 1 11 6 8 1 67 21 2 3 0 21 2 21 2 17 7 14 2 10 7 16 7 3 2 16 7 16 7 15 9 12 5 9 0 62 18 5 3 0 18 5 18 5 17 6 14 1 10 6 7 2 14 9 3 2 14 9 14 9 13 7 10 2 6 7 3 2 57 17 5 3...

Page 13: ...46 0 3 1 36 1 30 2 24 3 18 4 67 45 1 2 8 45 1 37 9 32 2 26 5 20 7 41 0 3 1 41 0 36 8 30 9 25 0 19 2 62 39 7 2 8 39 7 39 7 35 8 30 1 24 4 18 7 36 4 3 0 36 4 36 4 33 2 27 3 21 5 15 6 57 36 5 2 8 36 5 36...

Page 14: ...2 31 3 3 8 26 9 22 0 17 0 12 1 27 0 4 0 25 4 20 4 15 5 10 6 67 26 8 3 7 26 8 23 3 18 4 13 4 8 5 22 5 3 9 22 5 19 3 14 4 9 5 4 6 62 22 8 3 6 22 8 22 8 19 0 14 1 9 2 4 2 18 3 3 9 18 3 18 3 15 0 10 1 5 1...

Page 15: ...3 6 36 8 31 1 25 4 19 8 67 47 7 3 3 47 7 39 9 34 2 28 6 23 0 44 3 3 5 44 3 38 8 33 1 27 4 21 7 62 42 1 3 2 42 1 42 1 42 1 37 7 32 1 26 5 39 1 3 5 39 1 39 1 39 1 33 4 27 8 22 1 57 40 0 3 2 40 0 40 0 4...

Page 16: ...4 5 28 3 23 6 18 9 14 3 31 2 4 8 27 1 22 4 17 6 12 9 67 31 2 4 3 31 2 30 2 25 6 20 9 16 2 26 7 4 6 26 7 26 7 24 1 19 4 14 6 62 27 5 4 2 27 5 27 5 25 8 21 2 16 5 11 9 23 4 4 4 23 4 23 4 23 2 18 4 13 7...

Page 17: ...4 2 41 4 35 4 29 4 23 4 67 55 2 3 8 53 1 45 3 39 6 33 8 28 1 51 3 4 1 50 2 44 2 38 2 32 2 26 3 62 48 7 3 9 48 7 48 7 48 7 44 4 38 7 32 9 45 2 4 1 45 2 45 2 45 2 39 3 33 3 27 3 57 46 3 3 8 46 3 46 3 4...

Page 18: ...9 4 9 33 1 27 5 21 9 16 3 36 1 5 2 31 8 26 1 20 4 14 6 67 36 1 4 7 36 1 35 1 29 5 23 9 18 4 30 9 5 0 30 9 30 9 27 8 22 1 16 4 62 31 8 4 6 31 8 31 8 31 7 26 1 20 6 15 0 27 1 4 9 27 1 27 1 27 1 23 9 18...

Page 19: ...5 4 52 7 44 7 36 6 28 6 67 68 3 4 8 68 3 56 5 48 7 40 8 32 9 62 6 5 3 62 6 55 0 46 9 38 9 30 8 62 61 9 4 7 61 9 61 9 61 9 54 0 46 1 38 2 56 2 5 2 56 2 56 2 56 2 48 1 40 0 32 0 57 58 2 4 7 58 2 58 2 5...

Page 20: ...6 0 38 8 32 7 26 6 20 5 46 9 6 4 37 2 31 0 24 7 18 5 67 46 1 5 9 46 1 41 4 35 3 29 1 23 0 41 3 6 3 41 3 39 6 33 3 27 1 20 8 62 41 5 6 0 41 5 41 5 37 5 31 4 25 2 19 1 37 5 6 4 37 5 37 5 32 7 26 4 20 2...

Page 21: ...0 12 2 1000 72 32 3 1 7 26 8 22 5 18 2 13 9 28 0 1 9 23 9 19 8 15 7 11 5 67 26 8 1 6 26 8 25 6 20 5 16 2 11 8 25 0 1 8 25 0 24 4 20 2 16 1 11 9 62 25 6 1 6 25 6 25 6 25 6 21 3 17 0 12 6 22 2 1 8 22 2...

Page 22: ...7 8 15 4 2 7 15 4 13 5 10 2 6 8 67 15 0 2 5 15 0 15 0 14 8 11 5 8 2 11 1 2 7 11 1 11 1 11 1 9 1 5 7 62 13 4 2 4 13 4 13 4 13 4 10 1 6 8 3 5 10 9 2 7 10 9 10 9 10 9 7 6 4 2 0 8 57 13 6 2 4 13 6 13 6 1...

Page 23: ...32 5 2 4 27 8 23 3 18 8 14 2 67 32 5 2 1 32 5 31 4 25 7 21 3 16 9 30 1 2 4 30 1 29 6 25 1 20 5 16 0 62 29 7 2 1 29 7 29 7 29 7 25 3 20 9 16 6 27 5 2 4 27 5 27 5 27 5 23 0 18 4 13 9 57 28 5 2 1 28 5 2...

Page 24: ...1 23 2 19 0 14 8 10 7 22 5 3 4 22 1 18 0 13 8 9 7 67 21 4 3 0 21 4 21 4 19 9 15 7 11 5 18 0 3 3 18 0 18 0 18 0 14 4 10 3 62 20 3 3 0 20 3 20 3 20 3 16 1 11 9 7 8 17 5 3 3 17 5 17 5 17 5 13 5 9 4 5 3...

Page 25: ...43 3 3 0 33 1 27 6 22 1 16 6 67 43 2 2 7 43 2 36 2 30 8 25 4 20 0 39 7 3 0 39 7 35 1 29 6 24 1 18 6 62 39 8 2 7 39 8 39 8 39 8 34 4 29 0 23 6 35 6 3 0 35 6 35 6 35 6 30 1 24 6 19 1 57 39 2 2 7 39 2 3...

Page 26: ...3 0 17 8 12 6 29 4 4 2 26 9 21 7 16 5 11 3 67 28 1 3 8 28 1 28 1 24 9 19 7 14 5 24 1 4 1 24 1 24 1 23 3 18 1 12 9 62 26 3 3 8 26 3 26 3 26 3 21 1 15 9 10 7 23 8 4 1 23 8 23 8 23 8 18 5 13 3 8 1 57 28...

Page 27: ...8 2 3 6 45 2 36 5 27 8 19 1 67 47 5 3 2 47 5 47 5 37 7 29 0 20 3 43 7 3 5 43 7 43 7 36 2 27 5 18 8 62 42 4 3 2 42 4 42 4 42 4 33 7 25 0 16 3 39 1 3 5 39 1 39 1 39 1 30 5 21 8 13 1 57 40 6 3 2 40 6 40...

Page 28: ...6 4 3 34 5 27 7 20 9 14 1 31 0 4 7 31 0 26 2 19 4 12 6 67 31 2 4 2 31 2 31 2 27 8 21 0 14 2 26 8 4 6 26 8 26 8 26 0 19 2 12 4 62 29 2 4 2 29 2 29 2 29 2 22 4 15 5 8 7 25 8 4 6 25 8 25 8 25 8 19 0 12...

Page 29: ...6 4 4 0 52 4 42 4 32 5 22 6 67 57 3 3 6 57 3 57 3 45 7 35 8 25 8 50 3 4 0 50 3 50 3 41 6 31 6 21 7 62 51 6 3 5 51 6 51 6 51 6 41 7 31 8 21 8 45 1 3 9 45 1 45 1 45 1 35 2 25 2 15 3 57 48 1 3 5 48 1 48...

Page 30: ...0 2 5 0 39 1 31 3 23 5 15 8 34 5 5 5 34 5 29 4 21 6 13 8 67 34 8 5 0 34 8 34 8 31 1 23 3 15 5 29 5 5 5 29 5 29 5 28 7 21 0 13 2 62 32 7 4 9 32 7 32 7 32 7 24 9 17 1 9 3 28 7 5 4 28 7 28 7 28 7 20 9 13...

Page 31: ...5 2 55 4 45 1 34 8 24 4 67 61 2 4 8 61 2 56 5 44 5 32 7 20 9 57 7 5 2 57 7 55 3 45 0 34 7 24 4 62 58 6 4 7 58 6 58 6 58 6 46 8 35 1 23 3 53 7 5 1 53 7 53 7 53 7 43 3 33 0 22 7 57 53 6 4 7 53 6 53 6 5...

Page 32: ...6 2 38 9 32 8 26 6 20 5 43 9 6 7 35 5 30 2 24 8 19 5 67 45 5 6 2 45 5 41 2 35 1 28 9 22 8 41 4 6 7 41 4 38 8 33 5 28 2 22 8 62 40 7 6 1 40 7 40 7 40 7 34 6 28 5 22 3 36 9 6 6 36 9 36 9 36 9 31 7 26 4...

Page 33: ...2 21 2 27 2 33 2 39 2 45 2 51 2 57 2 63 1000 55 MBH 9 65 11 46 13 69 16 41 19 74 23 82 28 82 34 94 KW 1 44 1 50 1 56 1 62 1 68 1 74 1 80 1 86 70 MBH 8 10 9 91 12 14 14 86 18 19 22 27 27 27 33 39 KW 1...

Page 34: ...10 3 19 3 28 70 MBH 15 66 18 61 22 12 26 29 31 24 37 13 44 13 52 44 KW 3 14 3 23 3 32 3 41 3 51 3 60 3 69 3 78 80 MBH 13 53 16 48 19 99 24 16 29 11 35 00 42 00 50 31 KW 3 48 3 57 3 66 3 75 3 85 3 94...

Page 35: ...1154 446 1114 1027 397 1133 853 340 1153 042 3 5 NM Low 1095 233 853 1037 255 936 979 269 1003 904 283 1079 829 297 1154 Low Medium 1161 276 897 1104 298 973 1043 312 1040 978 325 1105 913 337 1171 Me...

Page 36: ...09 700 0 08 0 08 0 08 0 09 0 10 800 0 09 0 09 0 09 0 10 0 12 900 0 1 0 10 0 10 0 11 0 13 1000 0 12 0 12 0 12 0 13 0 15 1100 0 13 0 13 0 13 0 14 0 17 1200 0 15 0 15 0 15 0 16 0 19 1300 0 17 0 17 0 17 0...

Page 37: ...0 38 0 41 2100 0 39 0 39 0 39 0 40 0 43 2200 0 41 0 41 0 41 0 42 0 45 060 5 0 NM 800 0 09 0 09 0 09 0 10 0 12 900 0 1 0 10 0 10 0 11 0 13 1000 0 12 0 12 0 12 0 13 0 15 1100 0 13 0 13 0 13 0 14 0 17 12...

Page 38: ...048 4 0 UQ 208 230 1 60 1300 1300 1270 1270 060 5 0 UQ 208 230 1 60 1300 1300 1270 1270 Indoor Blower Specifications Size Tons Model Motor HP RPM Eff SF Frame 024 2 0 UM 1 2 1075 0 8 1 0 48 030 2 5 U...

Page 39: ...1506 10 8 14 3 1 51 7 59 7 68 8 78 8 70 80 70 80 030 2 5 208 230 1 60 10 6 54 0 16 6 1 4 3 3 None 18 0 25 25 2PH08520506 3 6 4 8 1 17 2 19 9 25 7 29 0 30 30 30 30 2PH08520706 4 9 6 5 1 23 5 27 1 33 5...

Page 40: ...8 1 17 2 19 9 47 8 51 1 60 60 60 60 2PH08520706 4 9 6 5 1 23 5 27 1 55 6 60 1 60 70 60 70 2PH08521006 7 2 9 6 1 34 5 39 8 69 4 76 70 80 70 80 2PH08521506 10 8 14 3 1 51 7 59 7 90 9 100 9 100 110 100...

Page 41: ...546039 YTG C 0211 Unitary Products Group 41 NM UQ024 060 Typical Wiring Diagrams NM024 030 and 036 Typical Cooling Unit 208 230 1 60 volt Wiring Diagram...

Page 42: ...546039 YTG C 0211 42 Unitary Products Group NM036 Typical Cooling Unit 208 230 3 60 volt Wiring Diagram...

Page 43: ...546039 YTG C 0211 Unitary Products Group 43 NM042 048 and 060 Typical Cooling Unit 208 230 1 60 volt Wiring Diagram...

Page 44: ...546039 YTG C 0211 44 Unitary Products Group NM048 and 060 Typical Cooling Unit 208 230 3 60 volt Wiring Diagram...

Page 45: ...546039 YTG C 0211 Unitary Products Group 45 NM048 and 060 Typical Cooling Unit 460 3 60 volt Wiring Diagram...

Page 46: ...546039 YTG C 0211 46 Unitary Products Group UQ024 060 Typical Heat Pump 208 230 1 60 volt Wiring Diagram...

Page 47: ...546039 YTG C 0211 Unitary Products Group 47 UQ036 048 and 060 Typical Heat Pump 208 230 3 60 volt Wiring Diagram...

Page 48: ...546039 YTG C 0211 48 Unitary Products Group UQ060 Typical Heat Pump 460 3 60 volt Wiring Diagram...

Page 49: ...16 68 71 71 68 UQ 328 325 21 75 14 75 67 86 96 030 2 5 NM 282 279 23 5 16 68 71 71 68 UQ 343 340 21 75 14 78 70 90 101 036 3 0 NM 318 315 22 15 5 80 73 78 85 UQ 348 345 23 5 15 79 83 94 90 042 3 5 NM...

Page 50: ...47 1 4 12 9 16 8 1 2 24 1 16 12 2 3 4 042 3 5 NM 32 13 16 30 15 16 47 1 4 12 9 16 8 1 2 24 1 16 12 2 3 4 UQ 32 13 16 34 15 16 57 9 16 11 9 16 10 5 16 28 7 8 14 2 3 4 048 4 0 NM 32 13 16 34 15 16 57 9...

Page 51: ...n Distance in Direction Distance in Top1 1 Units must be installed outdoors Over hanging structure or shrubs should not obscure condenser air discharge outlet 60 Right 24 Front 36 Left 24 Rear2 2 Unit...

Page 52: ...hange without notice Printed in U S A 546039 YTG C 0211 Copyright 2011 by Unitary Products Group All rights reserved Supersedes 546039 YTG B 0910 Johnson Controls Unitary Products 5005 York Drive Norm...

Reviews: