background image

CONFORMITY DECLARATION

AS DEFINED BY MACHINERY DIRECTIVE 89/392 EEC ANNEXE II A

        

WE  :            YORK Industrial (Thailand) Co., Ltd.

                104 Moo 2, Teparak Rd., Tambon Bangsaothong

                King-Ampher Bangsaothong. Samutprakarn 10540, Thailand.

    

DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE MACHINE :

       

Outdoor unit       MOC 07 to 55 and MOH 07 to 55

                

DESIGNATION :

  Indoor units        MCC 07 to 35 , MCH 07 to 35,

                           MSC 35 to 55, MSH 35 to 55,

                           MKC 12 to 55, MKH 12 to 55,

                          MAC 18 to 65, MAH 18 to 65

              

IS IN COMPLIANCE WITH REQUIREMENTS OF :

              •  MACHINERY DIRECTIVE CEE 89/392 AS MODIFIED WITH DIRECTIVES

                 CEE 91/368, 93/44, 93/68 (EEC 91/368, 93/44 AND 93/68)

              •  LOW VOLTAGE DIRECTIVE CEE73/23 (EEC 73/23)

              •  ELECTROMAGNETIC COMPATIBILITY DIRECTIVE CEE 89/336 (EEC 89/336)

                 

EC type certificate TCF n° 277

              IN ACCORDANCE WITH THE FOLLOWING HARMONIZED STANDARDS :

              •  EN 292/1, EN 292/2, EN 292-2A1, EN 60335-2-40, EN 50081-1, EN 50082-1

NAME                                   :  KACHIT

SURNAME                            :  SRIMUNCHU

POSITION                             :  ENGINEERING MANAGER

               SIGNATURE                         :

11

Summary of Contents for MOH 55

Page 1: ...MOC MOH MCC MCH MINISPLIT Floor Ceiling 035T70004 001 TECHNICAL GUIDE Cooling only and Heat Pump Systems Models MCC MOC MCH MOH 35 to 55 Infrared remote control...

Page 2: ...e that the power supply has been disconnected ELECTRICAL CONNECTIONS All electrical wiring and connections must comply with local standards Power supply cord used must not be lighter than Polychloropr...

Page 3: ...C MOH Piping Diameter Dimensions and Weights Indoor Outdoor Indoor unit Outdoor unit V Ph Hz Ph kW A A A m h Connection Type V Ph Hz Ph kW A A A m h Type gr Suction Liquid H mm W mm D mm kg 220 240 1...

Page 4: ...nections unit wiring connections 5 1 Unit clearances A minimium of clearance is necessary around the units to ensure proper air circulation and easy access for maintenance Clearance required for indoo...

Page 5: ...ling mounted units installation close to a wall facilitates piping Usetheknockoutsintheunitcasingwhenroutingthepipes Hook the indoor unit on the mounting brackets Check that the unit is level so that...

Page 6: ...into them from the outdoor unit 1 Remove the cap from the service valve 2 Connect the line to a vacuum pump and pump down to 5 Pa 3 When pump down is finisned wait 15 minutes to detect potential circ...

Page 7: ...d the temperature set point entered on the control SYSTEM OPERATION MODE SELECTION ROOM TEMPERATURE SETTING Press the TEMP button up or down to change the setting to the desired room temperature The s...

Page 8: ...d working condition Also make sure that the controlispointeddirectlyattheairconditioningunitwhenyouareusing it that the distance is a maximum of 10 meters and that there are no obstacles between the r...

Page 9: ...it Outdoor unit Outdoor unit 9 10 Service and Maintenance The units are designed to operate for long periods of time with a minimum of maintenance However the following operations must be performed re...

Page 10: ...ty correction factor for temperature Capacity correction factor for indoor fan speed C3 Fan speed Correction factor C3 Indoor unit High 1 Medium 0 90 Low 0 75 Indoor unit 10 0 98 5 1 00 Piping length...

Page 11: ...35 MSC 35 to 55 MSH 35 to 55 MKC 12 to 55 MKH 12 to 55 MAC 18 to 65 MAH 18 to 65 IS IN COMPLIANCE WITH REQUIREMENTS OF MACHINERY DIRECTIVE CEE 89 392 AS MODIFIED WITH DIRECTIVES CEE 91 368 93 44 93 6...

Page 12: ...tem of the unit into a suitable container using a refrigerant reclaim or recovery unit This refrigerant may then be re used if appropriate or returned to the manufacturer for disposal Under No circums...

Reviews: