2 - Indoor & outdoor units

3 - Technical specifications

2.1 - Indoor unit

Each unit is shipped with the following items:

- an indoor unit ready for connection to the condensing unit,
- mounting brackets,
- a technical tuide,
- a user's tuide,
- an infrared remote control with a wall bracket and 2 batteries,
- a cut-out template for the casing printed on the cassette

packing box.

2.2 - Panel with return grille for indoor unit.

2.3 - Outdoor unit

The units are shipped complete with a charge of R22 refrigerant

sufficient for a piping length of 7.5 metres.

2.4 - Auto restart and anti freeze protection

- After a power failure, the unit restarts automatically (when

power is resumed) in the same mode.

- When evaporator surface temperature is –2°C, the compressor

is stopped, the fan continues to run. Compressor operation is

resumed when temperature rises to 0°C.

Indoor

MKC - MKH

Models

unit

12S

18S

24S

Outdoor

MOC - MOH

unit

12

18

25

Cooling

Btu/h

12 000

18 000

24 000

kW

3.5

5.3

7

Capacities

Heating

Btu/h

12 500

18 500

25 100

kW

3.6

5.4

7.1

Electric heating

kW

2

2

2

(option)

Compressor

Type

Rotary

Reciprocating

Refrigerant

R-22

Power supply

V/Ph/Hz

220/240-1-50

Power input

kW

1.3

2

2.8

Nominal current

A

6.3

9.4

13

Current draw (Electric heat)

A

9.1

9.1

9.1

Indoor air flow

m

3

/h

640

850

950

Noise level at 3m

Indoor

dBA

18/24/27

26/30/33

32/36/38

Outdoor

37

55

56

Operating controls

Wireless remote control

H (mm)

300/492

300/590

300/696

Dimensions

Indoor/Outdoor

W (mm)

575/764

575/820

575/850

D (mm)

575/230

575/280

575/287

Net weight

Indoor

kg

20

22

24

Outdoor

38

59

65

Type of connection

Flared

Piping

Diameter

Gas

1/2"

5/8"

5/8"

Liquid

1/4"

3/8"

3/8"

Dehumidification

l/h

1.7

2.5

3.2

Nominal cooling capacity based on :

Nominal heating capacity based on :

- Indoor air temp. 27°C DB/19°C WB

- Indoor air temp. 21°C DB - Outdoor air temp. 7°C DB/6°C WB

- Outdoor air temp. 35°C DB

Piping length : 7.5 m

<--

Summary of Contents for MOC12

Page 1: ...Cassette MINISPLIT MKC MKH 12 18 24 Infrared remote control MOC MOH YORK...

Page 2: ...ning Dismantling and Disposal 1 Safety Installation and maintenance of this air conditioning system should only be carried out by trained and qualified personnel Regular maintenance operations such as...

Page 3: ...0 C Indoor MKC MKH Models unit 12S 18S 24S Outdoor MOC MOH unit 12 18 25 Cooling Btu h 12 000 18 000 24 000 kW 3 5 5 3 7 Capacities Heating Btu h 12 500 18 500 25 100 kW 3 6 5 4 7 1 Electric heating k...

Page 4: ...istics table on page 3 Outdoor unit MOC MOH 12 18 Outdoor unit MOC MOH 25 H L P Clearances required for outdoor units C B E A D 5 4 2 3 660 575 1 660 1 False ceiling 2 Condensate drainage 3 Gas line c...

Page 5: ...is way and the remote control is forced off line The tempera ture setpoint is set at 24 C both in the heating and cooling mode To revert to normal remote control operation set the selector to the NOR...

Page 6: ...ulated to prevent dro plets of condensation from dripping on the false ceiling Connect the drainage tube int 12 mm coming from the pump to a P V C drainage line 32 mm mini It is advisable to install a...

Page 7: ...oid alteration of unit capacities make sure that piping lengths and changes in elevation are kept to a strict minimum Before connecting the refrigerant lines follow the procedures below if pre charged...

Page 8: ...s Fit the casing and grille together using the screws fig 5 ref b Put the filter fig 6 and the return air grille fig 6 7 back in place 8 Wiring diagram 9 Front panel installation 1 N E 2 1 N E A 2 Pow...

Page 9: ...g 6 a a a a A Cooling operation summer Coanda effect Heating operation winter Detail A Depending on the configuration of the room to be air conditioned one or two of the deflectors may be left closed...

Page 10: ...y can be determined by using correction fac tors C1 C2 and C3 Given cooling capacity Cooling capacity at standard rating conditions x C1 x C2 x C3 C1 Capacity correction factor for temperature C2 Capa...

Page 11: ...12 18 24 MKH 12 18 24 SERIAL NUMBER IS IN COMPLIANCE WITH THE REQUIREMENTS OF APPLICABLE EEC DIRECTIVES 89 392 EC 89 336 CEE NATIONAL STANDARDS AND TECHNICAL SPECIFICATIONS ISO 9001 Pr EN378 AND IN AC...

Page 12: ...very unit This refrigerant may then be re used if appropriate or returned to the manufacturer for disposal Under NO circumstances should refrigerant be vented to atmosphere Where appropriate drain the...

Reviews: