INSTALLATION

Unit installation details:

– unit mounting plenum electric heater installation
– refrigerant piping connections

– condensate water drainage connections
– unit wiring connection

UNIT CLEARANCES

A minimum of clearance is necessary around the units to ensure proper air circulation and easy access for maintenance.

CLEARANCE REQUIRED FOR INDOOR UNITS

150

500

Plenum Electric Heater

250

Plenum Electric Heater

CLEARANCE REQUIRED FOR OUTDOOR UNITS

Unit

A

B

C

D

E

25

400

200

100

300

600

35

400

200

100

300

800

45

400

200

100

300

800

55

400

200

100

300

800

65

400

200

100

300

800

MOC - MOH

Table 1

MOC/MOH 25-35

C

B

D

A

E

MOC/MOH 45-65

A

D

C

E

B

OUTDOOR UNIT INSTALLATION

OK

Picture 1

PLENUM AND ELECTRIC HEATER INSTALLATION

1. The electric heater is installed by

factory. (Picture 1)

2. Fixed the plenum with electric heater.

(Picture 2)

3. Connected wiring see at the diagram.

(Item 10 wiring diagram)

Indoor Unit

Electric Heater

Plenum

Indoor Unit

Electric Heater

Picture 2

Summary of Contents for MBC-MBH 25

Page 1: ...nditioning system should only be carried out by trained and qualified personnel Regular maintenance operations such as cleaning the coils and air filters must be performed to keep the units in proper...

Page 2: ...Outdoor Unit it Power Supply Indoor Unit Fan Air flow Running Current Input Power Electric Heater MBC MBH MOC MOH 220 240 1 50 or 380 415 3 50 Models Power Supply High Static Duct Type MBC MBH P with...

Page 3: ...0 924 Model MBC MBH25 H mm 300 W mm 710 D mm 300 1404 MBC MBH35 MBC MBH45 MBC MBH50 55 MBC MBH65 400 400 400 400 A mm 400 220 220 220 220 220 CONTROL BOX MBC MBH 35 65 LH VIEW REAR VIEW RH VIEW FRONT...

Page 4: ...r 250 Plenum Electric Heater CLEARANCE REQUIRED FOR OUTDOOR UNITS Unit A B C D E 25 400 200 100 300 600 35 400 200 100 300 800 45 400 200 100 300 800 55 400 200 100 300 800 65 400 200 100 300 800 MOC...

Page 5: ...hout any upward slopes An elbow trap at least 50 mm in height must also be provided If possible install a U bend fitted with an inspection cap REFRIGERANT PIPING CONNECTIONS Where the condensate lines...

Page 6: ...H Airflow 1800 2000 3200 2200 2400 2600 2800 3000 Available Ext Static Pa HI ME LO Fan Performance MBC MBH 35 250 200 150 100 50 0 1400 1600 1800 415 470 525 580 635 690 745 800 L S CMH 2000 2200 Airf...

Page 7: ...ssor start up will be delayed until 3 minutes has passed SYSTEM OPERATION MODE SELECTION There are five different operating modes Cool Only and Heat Pump Units Cooling mode Electric Heating Units Only...

Page 8: ...e control is equipped with a diagnostic information system to report operation of the unit as well as operational failures If your remote control does not operate properly first check the polarity of...

Page 9: ...fore start up Each season before start up MAINTENANCE OPERA COMPONENT TIONS 1 Clean with a vacuum cleaner or tap gently then wash in warm water 40 C with a mild detergent 2 Rinse and dry before replac...

Page 10: ...hing and safety precautions Read the Manual Risk of electric shock Unit is remotely controlled and may start without warning 1 Isolate all sources of electrical supply to the unit including any contro...

Reviews: