MANUAL OPERATION

 

 

Manual operation can be used temporarily in case you can not find the remote controller or its batteries are exhausted.

 

 
 
 
 
 
 

Manual control button

 

 

 
 
 
 
 
 
 

 

Manual control button

 

 

 

1

 

Open and lift the front panel up to an angle until it remains fixed

 

 

with a clicking sound.

 

 

2

 

Push the button until the AUTO indicator is lit, the unit will work 
in forced AUTO mode.

 

 

3

 

Close the panel firmly to its original position.

 

 
 

CAUTIONS

 

 

 

Once you push the manual button, the operation mode is shifted 
in an order as: AUTO, COOL, OFF. 

 

 

Push  the  manual  button  until  the  operation  indicator  flashes 
rapidly  (five  times  per  second),  the  unit  now  operating  in  forced 
COOL  mode.  This  is  used  for  testing  purposes  only.  On  forced 
COOL mode, the remote operation function is unavailable. 

 

 

When the OPERATION indicator goes off, the air conditioner is OFF. 

 

 

To restore the remote controller operation, use the remote 
controller directly. 

 

 

 
 

HOW THE AIR CONDITIONER WORKS

 

 
 

 

operation suppression zone

 

 

 

 

■ 

AUTOMATIC OPERATION

 

  

•  When you set the air conditioner in AUTO mode, it will automatically 

EN

 

select cooling, heating (cooling/heating models only), or fan only 
operation depending on what temperature you have selected and

 

 

 

o

p

e

ra

tio

n

 st

a

rts

 

 

 

1

 

 

1 hours

 

 
 

2

 

 

Set temperature

 

 

2 hours

 

 

the room temperature.

 

 

 

The air conditioner will control room temperature automatically 
round the temperature point set by you. 

 

 

If the AUTO mode is uncomfortable, you can select desired 
conditions manually. 

 

 

ECONOMIC Operation

 

 

 
 
 
 

Cooling 

Fan only  Cooling 

Fan only  Cooling

 

 
 

Room

 

temperature

 

Time

 

 

set temperature

 

 

 

DRYING operation

 

 

■ 

ECONOMIC OPERATION

 

 

When you push ECONO button during cooling, heating (cooling only type 
without),or  AUTO  operation,  the  air  conditioner  will  start  following 
operation.  The  fan  speed  will  be  automatically  controlled.  In  the 
operation  suppression  zone  where  capacity  is  kept  to  the  minimum, 
overcooling is prevented by raising the temperature setting by 1°C after 1 
hour and by 2°C after 2 hours of operation. The room temperature is thus 
regulated  between  the  operation  suppression  zone  and  the  set 
temperature. (It depends on the outdoor temperature.)

 

 

■ 

DRYING OPERATION

 

 

 

The dry mode will automatically select the drying operation based 
on  the  difference  between  the  set  temperature  and  the  actual 
room temperature. 

 

 

The  temperature  is  regulated  while  dehumidifying  by  repeating 
turning  on  and  off  of  the  cooling  operation  or  fan  only.  The  fan 
speed indicator will display AUTO and low speed will be used. 

 

 

 
 
 
 
 

ENGLISH

 

5

 

 

 

 

J174_lastRev4.pmd

 

5

 

3/14/05, 3:27 PM

 

 

 

 

Summary of Contents for HLEA-HLDA 07-36

Page 1: ...ual MINISPLIT MODELS HLCA HLHA 07 36 HIGH WALL HECB HEHB 07 30 HLEA HLDA 07 36 AIR CONDITIONER The units comply with one or more of the following marks see unit for details EN035M80000 000 J174_lastRe...

Page 2: ...5 Optimal operation 6 Preparation Before Installation 6 Installation Procedure 8 Maintenance 16 Operation tips 17 Trouble Shooting Guide 18 Technical Specification 19 Declaration of conformity 23 R22...

Page 3: ...e dangerous and can cause injury Installation and maintenance of this air conditioning system should only be carried out by trained and qualified personnel After unpacking please check the unit carefu...

Page 4: ...panel on the indoor unit would look like one of following NOTE All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased T...

Page 5: ...erature you have selected and operation starts 1 1 hours 2 Set temperature 2 hours the room temperature The air conditioner will control room temperature automatically round the temperature point set...

Page 6: ...in breaker capacity are sufficient and the installation area is sufficient and complies with the requirements Check that the power supply available agrees with name plate voltage Electrical work wirin...

Page 7: ...128 245 5 420 540 527 272 298 780 10 548 115 45 90 266 48 HLDA HLJA 18 HEDB HEJB 18 HLDA HLJA 21 30 HEDB HEJB 21 30 HLDA HLJA 18 220 230V 60Hz UL 843 313 301 5 351 2 5694 135 141 5 560 1 235 125 335...

Page 8: ...ction or 6 0 A more ormore 10cm ore m or B 100cm 60cm or more C Loop the connective cable INSTALLATION PROCEDURE INDOOR UNIT Fixing Place the installation guide pattern on the designated installation...

Page 9: ...cable to terminal as identified with their respective marking Do not damage the conductor core or inner insulation of power supply cables and do not deform or crush the cables A Right B Right D Right...

Page 10: ...t be transmitted to the building structure NOTE Connect the pipe correctly Do not apply the excessive torque Use an appropriate bending tool to form curves and avoid over tightening the refrigerant tu...

Page 11: ...door Unit Liquid Line R22 R407C This unit is shipped complete with a charge of R22 R407C refrigerant that will be sufficient for an interconnecting piping length of 5 meters EN COLD AREA RECOMMENDATIO...

Page 12: ...led installation acceptance please refer to your contract with the power supplier if restrictions do apply for products like washing machines air conditioner or electrical ovens 4 For power details of...

Page 13: ...0Hz 380 415V 3Ph 50Hz 430V 3Ph 60Hz 430V 3Ph 60Hz For correct installation a proper ground connection must be made for unit Wiring Connection EN Model 07 21 Indoor Terminal block of indoor unit Outdoo...

Page 14: ...ling only type Cooling only type Model 30 3 Ph Indoor Outdoor Terminal block of indoor unit Terminal block of indoor unit Terminal block of outdoor unit Terminal block of outdoor unit 1 2 3 4 1 2 3 4...

Page 15: ...g only 1 Condition to start defrosting Units will switch to defrosting b Unit has been running at high temperature protection EN mode when either of the following conditions is met mode for 90 minutes...

Page 16: ...rom its support frame The installation and removing method of the air freshening filter is different depending on the models see the pictures marked 1 and 2 on the left Clean the air freshening filter...

Page 17: ...a normal condition when the air conditioner has not been used for a long time or during first use of the unit 5 A peculiar smell come out from the indoor unit This is caused by the indoor unit giving...

Page 18: ...separately together 3 The room was probably very hot 3 Wait while unit has enough time to cool when you star ted the cool the room system D The compressor run continuously 1 Thermostat adjustment too...

Page 19: ...4 e58 e60 59 Power Supply V Ph Hz 220 240 1 50 or 380 415 3 50 A 1 1 1 1 1 1 1 1 Air flow Hi Mi Lo m 3 h 380 350 320 450 420 390 550 500 460 750 710 650 800 760 700 1050 950 850 1150 1050 950 1350 120...

Page 20: ...Hz 220 230 1 60 Ph 1 1 1 1 1 1 1 Air flow Hi Mi Lo m 3 h 380 350 320 450 420 390 550 500 460 750 710 650 800 760 700 1050 950 850 1150 1060 960 U nit Fa n Input Power W 31W 1350 RPM 55 67 64 61 75 68...

Page 21: ...920 800 100 1000 880 U nit Fa n Input Power W 23 23 72 74 Indo or Running Current A 0 1 0 1 0 33 0 34 Height mm 250 280 330 330 Dimension Width mm 750 815 1080 1080 Depth mm 188 195 245 245 Weight kg...

Page 22: ...Power Supply V Ph Hz 220 240 1 50 or 380 415 3 50 Ph 1 1 1 1 1 1 1 Air flow Hi Mi Lo m 3 h 430 400 370 470 440 410 500 450 400 800 770 740 1050 950 850 1150 1050 950 U ni t Fa n Input Power W 37 5 36...

Page 23: ...horized Representative CM Choi Shipping Manager YORK International Northern Asia Ltd 15 F Tower II World Trade Square 123 Hoi Bun Road Kwun Tong Kowloon Hong Kong Telephone 852 2331 9286 Fax 852 2331...

Reviews: