5.4 Enabling the test
Figure 4: Test Enable switch and indicator
The selected test mode is enabled by pressing the Start Test switch
and the
indicator displays the running test status.
5.5 Test Supply Indicators
The HFG02 monitors the input from the Test Supply under test and displays the
voltage and frequency measurements on the front panel indicators as shown in
Table 2.
Test Supply monitoring is continuous and automatic, and does not require a test
mode to be enabled. Tests are automatically disabled if the Test Supply voltage or
frequency are outside their permitted ranges.
Test Supply Voltage
Voltage measured
Display Indication
110 VAC LED 230 VAC LED
Supply voltage not detected
Below detection range
Invalid voltage – too low
< 80 VAC
110 Vac range
80 to 130 VAC
Invalid voltage – mid range
130 to 200 VAC
230 Vac range
200 to 253 VAC
Invalid voltage – too high
> 253 VAC
Test Supply Frequency
Frequency measured
Display Indication
50 Hz LED
60 Hz LED
Supply input not detected
Below detection range
Invalid frequency – too low
< 49 Hz
50 Hz range
49 to 51 Hz
Invalid frequency – mid
range
51 to 59 Hz
60 Hz range
59 to 61 Hz
Invalid frequency – too high
> 61 Hz
Table 2: Test Supply measurement indicators