background image

All dimensions are in inches. They are
subject to change without notice. Certified
dimensions will be provided upon request.

CLEARANCES

Overhead (Top)

1

120"

Front
(Piping and Access Panels)

30"

Left Side

24"

Right Side

24"

Rear

24"

Bottom

2

0"

1Units must be installed outdoors. Overhanging structures or
  shrubs should not obstruct condenser air discharge.

2

Adequate snow clearance must be provided if winter operation

   is expected.

Connection

Entry

Connection Size

15 Ton

20 Ton

Suction Line

A

1-5/8 ID

2-1/8 ID

Liquid Line

B

5/8 ID

5/8 ID

Power Wiring

C

2-1/8  KO

2-1/8KO

Control Wiring

D

7/8 KO

7/8 KO

Accessory Wiring

E

7/8 KO

7/8 KO

Accessory Wiring

F

1-3/8 KO

1-3/8 KO

CONDENSING UNIT ONLY COOLING CAPACITIES AND POWER REQUIREMENTS

UNIT DIMENSIONS & CLEARANCES

F R O N T

A

3 9   -   7 / 8

B A C K

( C O I L   E N D )

A P P R O X I M A T E

C E N T E R   O F   G R A V I T Y

B

7 6   -   7 / 8

A I R

O U T

A I R

O U T

A I R

I N

O

O

O

5 - 3 / 4

4 4 - 9 / 3 2

F A N   M O T O R

  A C C E S S

C O M P R E S S O R   A N D

F A N   M O T O R   A C C E S S

E X T E R N A L   P R E S S U R E  

G A U G E   F I T T I N G S

C O N T R O L   B O X

A C C E S S

9 - 1 / 3 2

7 6 - 7 / 8

7 - 1 / 3 2

3 9   -   7 / 8

1 3 - 1 / 4

3 0 - 3 / 4

2 4 - 1 / 2

1 2 - 1 / 8

C

D

F

E

F

E

F

A

B

Unit

Dim. (in.)

A

B

15 Ton

16

32

20 Ton

16

32

CENTER OF GRAVITY

Compressor Suction

Ambient Temperature Entering Condenser Coil (°F)

Model

65

75

85

95

105

115

Pressure 

(psig)

Saturated 

Temp (°F) MBH

1

kW

2

MBH

kW

MBH

kW

MBH

kW

MBH

kW

MBH

kW

54.9

30

165

12.3

157

13.4

150

14.8

142

16.3

134

18.1

126

19.9

61.6

35

181

12.5

172

13.6

164

15.0

156

16.5

147

18.3

138

20.2

180

68.5

40

196

12.7

188

13.9

179

15.3

170

16.7

160

18.6

151

20.4

76.0

45

212

12.9

204

14.1

194

15.5

184

17.0

174

18.9

164

20.8

84.0

50

231

13.2

220

14.3

210

15.8

199

17.3

188

19.1

177

21.0

54.9

30

228

17.3

217

19.2

206

21.1

195

23.4

183

25.9

172

28.5

61.6

35

248

17.7

237

19.6

225

21.5

213

23.8

200

26.4

188

29.0

240

68.5

40

269

18.1

257

20

244

21.9

231

24.3

218

26.9

204

29.6

76.0

45

291

18.5

277

20.5

264

22.4

250

24.8

236

27.5

222

30.3

84.0

50

313

19.0

299

21

284

23.0

269

25.3

254

28.1

239

30.9

1. Capacities are gross ratings.
2. Power is for the condensing unit only.

550.23-TG3Y

Unitary Products Group

3

Summary of Contents for H3CE180

Page 1: ...d copper tubes and louvered aluminum fins for durability and long lasting efficient operation Permanently attached base rails with fork lift slots and lifting holes This design allows for 3 way fork l...

Page 2: ...Rated in accordance with ARI 370 3 All ratings were determined with 25 feet of interconnecting tubing and with the air handler in the horizontal position For the 180 a 5 8 inch liquid line and an insu...

Page 3: ...D F A N M O T O R A C C E S S E X T E R N A L P R E S S U R E G A U G E F I T T I N G S C O N T R O L B O X A C C E S S 9 1 3 2 7 6 7 8 7 1 3 2 3 9 7 8 1 3 1 4 3 0 3 4 2 4 1 2 1 2 1 8 C D F E F E F A...

Page 4: ...ing Condenser Air Ent Power Air Temperature Entering Evaporator Dry Bulb Power Air Temperature Entering Evaporator Dry Bulb Evaporator Input 86 80 74 68 Input 86 80 74 68 CFM WB kW Total Sens Total Se...

Page 5: ...L3EU240 105 F Air Entering Condenser 115 F Air Entering Condenser Air Ent Power Air Temperature Entering Evaporator Dry Bulb Power Air Temperature Entering Evaporator Dry Bulb Evaporator Input 86 80 7...

Page 6: ...M O S T A T 2 T H 0 4 7 0 1 2 2 4 E V A P O R A T O R B L O W E R M O T O R C O N T A C T O R R C Y 2 Y 1 G 2 4 V X L L Y 2 C O M P R E S S O R 2 4 V L O C K O U T S I G N A L 2 V A M A X C O M P R E...

Page 7: ...e call for cooling has been removed When Y1 is returned to 0 volts the LOR coil is no longer energized closing the LOR 1 contacts and removing the lock out SUCTION LINE DATA1 2 LIQUID LINE DATA REFRIG...

Page 8: ...ontinues to lock out after resuming operation call a service technician to diagnose and repair the unit CAUTION Repeatedly resetting the lock out may cause damage to the unit Second Stage of Cooling T...

Page 9: ...xpanded and bonded to louvered aluminum fins Coil shall include an integral subcooler V Refrigeration Components Refrigeration system shall contain the following High and low pressure cut outs Suction...

Page 10: ...to provide further coil protection D Phenolic Coating on Condenser Coil Condenser coils shall be dipped in a four coat phenolic coating process to provide longer life in corrosive condi tions GUIDE SP...

Page 11: ...550 23 TG3Y Unitary Products Group 11...

Page 12: ...592 York Pennsylvania USA 17405 1592 Subject to change without notice Printed in U S A Copyright by York International Corporation 1998 All Rights Reserved Codes EBY EGY 550 23 TG3Y Supersedes 550 23...

Reviews: