background image

DESCRIPTION

These outdoor condensing units are completely assembled,
piped and wired at the factory to provide one-piece shipment
and rigging. Each unit is pressurized with a holding charge of
refrigerant-22 for storage and/or shipping.

The compact design, clean styling, and quiet operation make
these condensing units suitable for almost any outdoor
location. On rooftops . . . because they weigh much less than
a single package unit of similar capacity and are much easier
to rig and support. At ground level . . . because their ample
sub-cooling capacity allows them to be located 18 meters (60
feet) below the evaporator coil.

All sheet metal parts are constructed of commercial grade
(G90) galvanized steel. Before painting, each part is thoroughly
cleaned to remove any grease or dirt from its surfaces. The
external parts are then coated  a “desert sand” powder paint to
assure a quality finish for many years. This  coating system has
passed the 750 hour, salt spray test per ASTM Standard B117.

All models include a 1-year limited warranty on the complete
unit. The compressor carries an additional 4-year  warranty.

A matching line of Evaporator Blower units is also offered to
meet your precise capacity and air handling requirements. 

FEATURES

Condenser coil constructed of rifled copper tubes and
louvered aluminum fins for durability and long lasting
efficient operation.

Permanently attached base rails with fork lift slots and lifting
holes. This design allows for 3-way fork lift access and
overhead rigging.

Both high and low pressure controls.

Solid state motor protection to prevent the compressor from
operating at an unsafe condition.

Ball bearing condenser fan motors with 5/8 inch shafts.

Color-coded power and control wiring for easier service and
troubleshooting.

Anti-short cycle timer to protect the compressor.

A lockout circuit to prevent the unit from cycling on safety
control.

A 24-volt temperature control circuit.

Standard unit low ambient operation to (35

°

F).

A filter-drier  (shipped in the unit’s compressor
compartment for field installation near the evaporator coil).

Service valves with a back-seating access port for pressure
testing the system. Copper stub-outs are factory mounted
on the suction and liquid service valves to simplify the field
piping connections.

Separate panel for easy access to the control box without
affecting air flow across the condenser coil.

Exterior access to service pressure port connections.

Packaging suitable for outdoor storage.

An optional Phenolic coating is available where the
condenser coils are fully dipped in a phenolic coating
process to provide longer life in corrosive conditions.

550.23-TG3Y (398)

SPLIT-SYSTEM
AIR-COOLED
CONDENSING UNITS

H3CE180 & 240

15 AND 20 NOMINAL TONS

® 

O

O

O

Summary of Contents for H3CE180

Page 1: ...d copper tubes and louvered aluminum fins for durability and long lasting efficient operation Permanently attached base rails with fork lift slots and lifting holes This design allows for 3 way fork l...

Page 2: ...Rated in accordance with ARI 370 3 All ratings were determined with 25 feet of interconnecting tubing and with the air handler in the horizontal position For the 180 a 5 8 inch liquid line and an insu...

Page 3: ...D F A N M O T O R A C C E S S E X T E R N A L P R E S S U R E G A U G E F I T T I N G S C O N T R O L B O X A C C E S S 9 1 3 2 7 6 7 8 7 1 3 2 3 9 7 8 1 3 1 4 3 0 3 4 2 4 1 2 1 2 1 8 C D F E F E F A...

Page 4: ...ing Condenser Air Ent Power Air Temperature Entering Evaporator Dry Bulb Power Air Temperature Entering Evaporator Dry Bulb Evaporator Input 86 80 74 68 Input 86 80 74 68 CFM WB kW Total Sens Total Se...

Page 5: ...L3EU240 105 F Air Entering Condenser 115 F Air Entering Condenser Air Ent Power Air Temperature Entering Evaporator Dry Bulb Power Air Temperature Entering Evaporator Dry Bulb Evaporator Input 86 80 7...

Page 6: ...M O S T A T 2 T H 0 4 7 0 1 2 2 4 E V A P O R A T O R B L O W E R M O T O R C O N T A C T O R R C Y 2 Y 1 G 2 4 V X L L Y 2 C O M P R E S S O R 2 4 V L O C K O U T S I G N A L 2 V A M A X C O M P R E...

Page 7: ...e call for cooling has been removed When Y1 is returned to 0 volts the LOR coil is no longer energized closing the LOR 1 contacts and removing the lock out SUCTION LINE DATA1 2 LIQUID LINE DATA REFRIG...

Page 8: ...ontinues to lock out after resuming operation call a service technician to diagnose and repair the unit CAUTION Repeatedly resetting the lock out may cause damage to the unit Second Stage of Cooling T...

Page 9: ...xpanded and bonded to louvered aluminum fins Coil shall include an integral subcooler V Refrigeration Components Refrigeration system shall contain the following High and low pressure cut outs Suction...

Page 10: ...to provide further coil protection D Phenolic Coating on Condenser Coil Condenser coils shall be dipped in a four coat phenolic coating process to provide longer life in corrosive condi tions GUIDE SP...

Page 11: ...550 23 TG3Y Unitary Products Group 11...

Page 12: ...592 York Pennsylvania USA 17405 1592 Subject to change without notice Printed in U S A Copyright by York International Corporation 1998 All Rights Reserved Codes EBY EGY 550 23 TG3Y Supersedes 550 23...