EZ Zone/Meridian
Upgrade
31
036-21423-001 Rev. A (0602)
Upgrade Parts List Summary
All the standard components that are required or avail-
able for the Meridian to EZ Zone upgrades are summa-
rized below. See the upgrade examples on pages 8
through 13 of this manual for the parts lists that are
required for your specific application.
For other Meridian products such as CV Unit Control-
lers, Lighting Panel Controllers etc., please see pages
14 & 15 or consult the factory to see if these are avail-
able for your specific application.
P art N o
D escrip tio n
2ZS M 004702924
OE392-01-SYSM
S ystem M anag er
(U sed o n P lu s S y stem s)
In c lu d es: S y stem M an a g e r O n ly .
2ZZC004708124
OE751
E Z Zone To A uto -Zone Basic Upgrade K it
In c lu d es:
Z o n e M an ag er B o ard w / M o u n tin g S c re w s, P las tic S ta n d o ff K it fo r
Z o n e M a n ag er, R etu rn A ir S e n so r, U p g rad e L ab e l, In stallatio n In str u ctio n s.
2ZZC004708324
OE753
E Z Zone To A uto -Zone P lus U pgrade K it
In c lu d es: Z o n e M a n a g e r B o ard w / M o u n tin g S cr ew s, P lastic S tan d o f f K it fo r
Z o n e M a n ag er, M in iL in k w / M o u n tin g H ard w a re, R etu rn A ir S en so r, 3 W ay
D isp lay /K ey p ad C o n n ecto r c ab le, U p g rad e L ab el, In sta lla tio n In stru c tio n s.
2ZD S004700224
OE231
D uct Tem perature Sensor
(1 0 k o h m w ith 1 2 ” P ro b e, u sed fo r R etu rn o r S u p p ly A ir S en so r)
In c lu d es: D u ct T em p era tu re S en so r, 2 W ire w ith 1 2 ” L o n g P ro b e.
2ZO T004704424
OE250
O utside A ir Tem p erature Senso r
(1 0 k o h m )
In c lu d es: T em p eratu re S e n so r M o u n ted in W eath e rp ro o f H an d y B o x .
2ZE M 004703424
OE419-04
R em ote Data L ink (
M o d em - E x tern a l -1 4 ,4 0 0 B au d )
In c lu d es: M o d em an d 1 2 0 /9 V A C P o w er S u p p ly .
2ZC P004703124
OE361-04
C om m Link II
(U sed o n B asic & P lu s S y stem s )
In c lu d es: C o m m L in k II, P o w er S u p p ly & C ab les f o r C o n n ectio n to C o m p u ter an d
R em o te L in k are In clu d ed .
2ZZC004708 224
OE752
R ep lacem en t E P R O M C hip
C o n tain s A u to -Z o n e so f tw are to rep lac e E Z Z o n e so ftw ar e in Z o n e C o n tro lle r
In c lu d es: E P R O M C h ip
2ZZC004708 424
OE755
M odem Linc Central To C o m m Link II U pgrad e K it
In c lu d es: C o m L in k II E P R O M U p g rad e C h ip , U p g rad e L ab el
2ZZC004708524
OE754
M aster Interface B o ard T o M in iLin k U pgrade K it
In c lu d es: M in iL in k E P R O M U p g rad e C h ip , U p g rad e L ab el
2ZX X004708124
EC101600-3
B lank En closure C over
U sed to rep lace E Z Z o n e M as ter C o n tro ller C o v er w h en K ey p ad & D isp lay a re
n o t D esired . In clu d es: M e tal E n c lo su re C o v er O n ly
2ZV S004700024
Z oneV iew AZ S oftw are
W in d o w s B ased S o ftw are f o r A cc es sin g S y stem u s in g a P C
In c lu d es: 3 .5 ” F lo p p y In stallatio n D isk e tte s an d O p eratio n s M a n u a l.