background image

036-21233-002-A-0903

Unitary Products Group

7

TABLE 2: RATINGS COOLING/GAS HEATING

MODEL

DNH

NET COOLING CAPACITY

1

SOUND

RATING

(dbels)

2

GAS HEAT CAPACITY / EFFICIENCIES

MBH

SEER

3

INPUT
(MBH)

OUTPUT

(MBH)

AFUE

4

(%)

NUMBER OF

BURNERS

TEMP.

RISE

(°F) RANGE

018N03606

17.4

12.0

80

45

36

80.2

2

25 - 55

024N03606

23.8

12.4

81

45

36

80.2

2

25 - 55

024N05606

23.8

12.4

81

70

56

80.2

3

30 - 60

030N03606

28.0

12.0

80

45

36

80.2

2

25 - 55

030N03625

28.0

12.0

80

45

36

80.2

2

25 - 55

030N03646

28.0

12.0

80

45

36

80.2

2

25 - 55

030N05606

28.0

12.0

80

70

56

80.2

3

30 - 60

030N05625

28.0

12.0

80

70

56

80.2

3

30 - 60

030N05646

28.0

12.0

80

70

56

80.2

3

30 - 60

036N03606

36.0

12.0

81

45

36

80.4

2

25 - 55

036N03625

36.0

12.0

81

45

36

80.4

2

25 - 55

036N03646

36.0

12.0

81

45

36

80.4

2

25 - 55

036N03658

36.0

12.0

81

45

36

80.4

2

25 - 55

036N05606

36.0

12.0

81

70

56

80.2

3

25 - 55

036N05625

36.0

12.0

81

70

56

80.2

3

25 - 55

036N05646

36.0

12.0

81

70

56

80.2

3

25 - 55

036N05658

36.0

12.0

81

70

56

80.2

3

25 - 55

036N07206

36.0

12.0

81

90

72

80.1

4

30 - 60

036N07225

36.0

12.0

81

90

72

80.1

4

30 - 60

036N07246

36.0

12.0

81

90

72

80.1

4

30 - 60

036N07258

36.0

12.0

81

90

72

80.1

4

30 - 60

042N06506

42.0

12.0

80

80

64

80.6

3

25 - 55

042N06525

42.0

12.0

80

80

64

80.6

3

25 - 55

042N06546

42.0

12.0

80

80

64

80.6

3

25 - 55

042N06558

42.0

12.0

80

80

64

80.6

3

25 - 55

042N09006

42.0

12.0

80

108

87

80.8

4

45 - 75

042N09025

42.0

12.0

80

108

87

80.8

4

45 - 75

042N09046

42.0

12.0

80

108

87

80.8

4

45 - 75

042N09058

42.0

12.0

80

108

87

80.8

4

45 - 75

048N06506

48.0

12.0

84

80

64

80.8

3

25 - 55

048N06525

48.0

12.0

84

80

64

80.8

3

25 - 55

048N06546

48.0

12.0

84

80

64

80.8

3

25 - 55

048N06558

48.0

12.0

84

80

64

80.8

3

25 - 55

048N09006

48.0

12.0

84

108

86

80.6

4

35 - 65

048N09025

48.0

12.0

84

108

86

80.6

4

35 - 65

048N09046

48.0

12.0

84

108

86

80.6

4

35 - 65

048N09058

48.0

12.0

84

108

86

80.6

4

35 - 65

048N11006

48.0

12.0

84

135

107

80.5

5

45 - 75

048N11025

48.0

12.0

84

135

107

80.5

5

45 - 75

048N11046

48.0

12.0

84

135

107

80.5

5

45 - 75

048N11058

48.0

12.0

84

135

107

80.5

5

45 - 75

060N06506

59.0

12.0

84

80

64

80.7

3

25 - 55

060N06525

59.0

12.0

84

80

64

80.7

3

25 - 55

060N06546

59.0

12.0

84

80

64

80.7

3

25 - 55

060N06558

59.0

11.0

84

80

64

80.7

3

25 - 55

060N09006

59.0

12.0

84

108

87

80.9

4

35 - 65

060N09025

59.0

12.0

84

108

87

80.9

4

35 - 65

060N09046

59.0

12.0

84

108

87

80.9

4

35 - 65

060N09058

59.0

11.0

84

108

87

80.9

4

35 - 65

060N11006

59.0

12.0

84

135

107

80.2

5

45 - 75

060N11025

59.0

12.0

84

135

107

80.2

5

45 - 75

060N11046

59.0

12.0

84

135

107

80.2

5

45 - 75

060N11058

59.0

11.0

84

135

107

80.2

5

45 - 75

1.

Net Cooling Capacity = ARI 210 standard rating conditions.

2.

(dbels) = ARI 270-95

3.

Seasonal Energy Efficiency Ration - the total cooling output in BTU’s during a normal annual usage period for cooling divided by 
the total electric power input in watt-hours during the same period.

4.

AFUE = Annual Fuel Utilization Efficiency.

Summary of Contents for DNH018

Page 1: ...ibility and choices you need in today s market FEATURING COOLING GAS HEATING UNITS NATURAL GAS OR PROPANE LOW PROFILE QUIET OPERATION COMMON FOOTPRINT OPTIONAL SLIDE IN MOTORIZED DAMPERS OPTIONAL SLID...

Page 2: ...POWER SUPPLY 27 16 TYPICAL WIRING DIAGRAM 575 3 60 27 17 TYPICAL WIRING DIAGRAM LEGEND 28 18 WIRING DIAGRAM DETAIL B 460 575 3 60 POWER SUPPLY 29 LIST OF TABLES Tbl Pg 1 PHYSICAL DATA 6 2 RATINGS COOL...

Page 3: ...CONDENSATE PAN A non corrosive long lasting water tight pan is positioned below the evaporator coil to collect and drain all condensate Less collection of stagnate condensate will build up The conden...

Page 4: ...xter nally mounted re usable service access ports are provided on both the high and low lines for ease of evacuating and charging the system No final field mounting required EASY SERVICE ACCESS A larg...

Page 5: ...ns in each corner Kit also pro vides seal strip to assure a water tight seal 8 and 14 inch high roof curbs are available MANUAL OUTDOOR DAMPER Provides 0 through 50 outdoor air capability field adjust...

Page 6: ...TOTAL 1 800 2 200 2 400 2 400 2 400 3 000 3 000 CONDENSER COIL ROWS DEEP 1 1 1 2 1 2 2 FINS PER INCH 20 20 20 20 20 20 20 FACE AREA Sq Ft 11 7 11 7 11 7 11 7 14 7 14 7 14 7 CHARGE REFRIGERANT 22 lbs o...

Page 7: ...12 0 80 108 87 80 8 4 45 75 042N09025 42 0 12 0 80 108 87 80 8 4 45 75 042N09046 42 0 12 0 80 108 87 80 8 4 45 75 042N09058 42 0 12 0 80 108 87 80 8 4 45 75 048N06506 48 0 12 0 84 80 64 80 8 3 25 55 0...

Page 8: ...88 1 90 1 89 Sensible Capacity MBH 1 Entering Dry Bulb F 86 9 0 11 1 10 8 11 0 10 2 12 7 12 2 12 4 11 5 14 3 13 6 13 8 11 7 14 5 14 0 14 3 11 9 14 7 14 5 14 7 83 8 1 10 2 10 8 10 9 9 3 11 7 12 2 12 4...

Page 9: ...2 6 16 1 16 5 16 0 14 0 17 9 17 6 16 9 15 3 19 6 18 7 17 8 15 3 19 7 18 8 17 9 15 2 19 8 18 9 18 0 83 11 4 15 0 15 9 15 6 12 7 16 6 17 3 16 7 13 9 18 2 18 6 17 8 14 2 18 7 18 8 17 9 14 5 19 1 18 9 18...

Page 10: ...ty MBH 1 Entering Dry Bulb F 86 16 0 19 6 19 4 19 0 18 4 22 3 21 4 20 9 20 8 24 9 23 3 22 8 22 3 25 0 23 4 22 9 23 7 25 2 23 5 23 0 83 13 9 18 0 19 4 19 0 15 9 20 6 21 4 20 9 17 9 23 2 23 3 22 8 18 9...

Page 11: ...6 20 6 25 9 28 3 28 3 23 0 28 9 30 5 30 6 25 3 31 8 32 6 32 9 25 2 32 0 33 2 33 4 25 1 32 2 33 7 33 9 83 18 9 24 2 27 9 27 8 21 0 26 9 30 3 30 4 23 2 29 7 32 6 32 9 23 6 30 4 33 2 33 4 24 0 31 1 33 7...

Page 12: ...b F 86 24 8 31 0 29 9 29 5 28 2 34 9 32 7 32 2 31 6 38 7 35 5 35 0 34 0 39 1 36 2 34 8 36 3 39 4 35 0 34 5 83 21 8 28 0 29 9 29 5 24 7 31 6 32 7 32 2 27 5 35 3 35 5 35 0 29 3 36 8 35 2 34 8 31 1 38 4...

Page 13: ...86 31 8 39 0 39 9 39 9 34 3 41 4 40 8 40 7 36 9 43 8 41 6 41 5 40 3 45 7 42 8 42 8 43 8 47 6 44 1 44 0 83 28 4 35 7 38 9 39 0 30 3 38 0 40 2 40 3 32 2 40 3 41 6 41 5 35 0 43 3 42 8 42 8 37 9 46 2 44 1...

Page 14: ...86 41 8 51 8 53 0 51 7 43 6 54 0 53 8 52 6 45 5 56 2 54 6 53 4 47 1 56 7 54 3 56 1 48 7 57 3 54 0 52 8 83 36 9 47 0 52 2 51 7 38 4 48 9 53 4 52 6 39 9 50 7 54 6 53 4 41 2 52 3 54 3 53 1 42 5 53 8 54 0...

Page 15: ...977 477 LOW 1191 527 1149 510 1107 494 1065 477 1009 459 952 441 042 HI 1681 797 1610 768 1540 740 1465 712 1390 685 1315 657 1204 623 1093 588 MED 1432 650 1381 628 1330 605 1279 583 1210 556 1140 5...

Page 16: ...1075 534 LOW 1384 625 1336 605 1287 584 1239 564 1167 537 1094 509 048 HI 1906 982 1857 960 1809 938 1758 913 1706 888 1648 861 1590 834 1445 783 1301 731 MED 1734 848 1693 821 1651 794 1595 764 1539...

Page 17: ...500 961 474 LOW 1239 510 1184 496 1130 481 1075 467 998 448 922 428 042 HI 1687 763 1614 737 1540 712 1458 688 1377 663 1295 639 1147 600 MED 1482 628 1428 613 1374 599 1320 584 1242 556 1163 528 1085...

Page 18: ...163 2045 1125 1953 1085 1860 1045 1698 990 1535 935 MED 2159 1125 2098 1090 2036 1055 1967 1020 1897 985 1814 945 1731 905 1578 582 LOW 1937 990 1892 983 1846 935 1785 908 1723 880 1655 843 1587 805 0...

Page 19: ...rn air If the resistance of the return air duct system is less then 0 25 IWG the unit will deliver less CFM during full economizer operation R G W R G C Y Y W C PROGRAMMABLE THERMOSTAT ONLY Minimum wi...

Page 20: ...8 9 25 25 96 75 036 460 3 60 414 504 5 7 39 0 6 1 8 9 5 15 15 96 75 036 575 3 60 518 630 4 7 31 0 4 1 5 7 8 15 15 96 75 042 208 230 1 60 187 253 20 0 104 1 3 3 5 29 8 40 40 96 40 042 208 230 3 60 187...

Page 21: ...OVERALL All dimensions are in inches They are subject to change with out notice Certified dimensions will be provided upon request TABLE 17 UNIT DIMENSIONS FRONT UNIT SIZE DIMENSION A B 018 036 33 1 2...

Page 22: ...D R A I N 3 4 N P T I G A S S U P P L Y 1 5 8 D I A K N O C K O U T 1 2 N P T I C O N N E C T I O N L O W V O L T A G E C O N N 1 8 D I A K N O C K O U T 1 3 4 1 5 2 9 9 1 6 1 5 3 1 2 1 3 4 1 3 4 1 5...

Page 23: ...L G A S S H U T O F F V A L V E R E T U R N A I R D U C T S U P P L Y A I R D U C T C O N T R O L W I R I N G T O I N D O O R T H E R M O S T A T T O P O W E R S U P P Y M A N U A L G A S S H U T O F...

Page 24: ...O U N D I N S T A L L A T I O N TABLE 19 UNIT WEIGHTS AND CENTER OF GRAVITY UNIT SIZE SHIPPING WEIGHT lbs OPERATING WEIGHT lbs CORNER WEIGHTS location lbs ECONOMIZER lbs ROOF CURB lbs A B C D 018 365...

Page 25: ...1 8 X 2 1 1 2 R E C O M M E N D E D D U C T S I Z E 1 7 1 2 X 1 6 3 4 1 8 Roof curb also available 3 4 X 1 W I D E G A S K E T I N G F O R C U R B F R A M E A N D A L L D U C T S U P P O R T S U R F...

Page 26: ...roup FIGURE 13 TYPICAL WIRING DIAGRAM 208 230 1 60 POWER SUPPLY FIGURE 14 TYPICAL WIRING DIAGRAM 208 230 3 60 POWER SUPPLY SEE DETAIL A T2 M1 2 DETAIL A L 2 BLK BLK CCH L1 T1 OPTIONAL CCH S P CONFIGUR...

Page 27: ...036 21233 002 A 0903 Unitary Products Group 27 FIGURE 15 TYPICAL WIRING DIAGRAM 460 3 60 POWER SUPPLY FIGURE 16 TYPICAL WIRING DIAGRAM 575 3 60...

Page 28: ...ry wired for low or medium speed indoor blower operation to change motor speed connect speed tap wires from indoor blower motor per Detail B Figure 18 tape unused speed tap wires to prevent shorting a...

Page 29: ...ly mounted condenser coil guard to provide protection from objects and personnel after installation Indoor blower section shall be insulated with up to 3 4 thick aluminum foil faced insulation fastene...

Page 30: ...xpansion blow through design while condenser coil shall be draw through design Refrigerant Circuit and Refrigerant Safety Components a Shall include independent fixed orifice expansion devices b Shall...

Page 31: ...036 21233 002 A 0903 Unitary Products Group 31...

Page 32: ...o change without notice Printed in U S A 036 21233 002 A 0903 Copyright by Unitary Products Group 2003 All rights reserved Supersedes 036 21233 001 D 0603 Unitary 5005 Norman Products York OK Group Dr...

Reviews: