background image

036-21233-002-A-0903

Unitary Products Group

3

DESCRIPTION

These packaged cooling/heating air conditioners are 
designed for outdoor installation. Only utility and duct con-
nections are required at the point of installation.

The gas-fired heaters have aluminized steel tubular heat 
exchangers and hot surface to pilot ignition. They are avail-
able in natural gas with field conversion to propane.

STANDARD FEATURES/BENEFITS

OPERATING EFFICIENCY - All units provide high operating 
efficiencies and have a minimum AFUE of 80% and SEER of 
up to 12.4. All efficiencies exceed legislated minimum levels.

ON SITE FLEXIBILITY - All model sizes share a common, 
compact design cabinet in a single footprint. The installer has 
the flexibility of setting one curb and placing the proper ton-
nage unit on that curb after the internal load has been deter-
mined. Field convertible duct connections from side shot to 
down shot allows the installer to have greater flexibility with 
less inventory.

LOWER INSTALLATION COST - Installation time and costs 
are reduced by easy power and control wiring connections. 
The small base dimension means less space is required on 
the ground or roof, plus, the installer can fit this unit between 
the wheel wells of full size pick-up truck. All models are well 
under 500 pounds.

All units are completely wired, charged with R-22 and tested 
prior to shipment. Unique test stations using a new state of 
the art computerized process system are used to insure prod-
uct quality. Refrigerant charge, and component part numbers 
are verified via computers at assembly. Vital run test statistics 
such as system pressure, motor currents, air velocity and 
temperature, unit vibration, and gas system safeties are mon-
itored and recorded by the system to insure unit perfor-
mance.

Equal size, side supply and return duct connections allows 
easy hook-up of ducts to match low crawl spaces without 
transition pieces.

UTILITY CONNECTIONS MADE EASY - Gas and electric 
utility knockouts are provided through the bottom as well as 
the side of the unit. Utility connections can be made quickly 
and with a minimum amount of field labor. A field supplied 
and field installed electrical disconnect switch must be 
installed.

CONVERTIBLE AIRFLOW DESIGN - The bottom duct open-
ings are covered when they leave the factory ready to be 
used for a side supply / side return application. If a bottom 
supply / bottom return application is desired, you simply 
remove the two panels from the bottom of the unit and place 
them in the side supply / side return duct openings. No panel 
cutting is required and no accessory panel is necessary. 
Convertible airflow design allows maximum field flexibility and 
minimum inventory.

CONDENSATE PAN - A non-corrosive, long-lasting, water-
tight pan is positioned below the evaporator coil to collect and 
drain all condensate. Less collection of stagnate condensate 
will build-up. The condensate pan conforms to ASHRAE 62-
89 standards (Ventilation for Acceptable Indoor Air Quality).

CONDENSATE DRAIN - The heavy duty, 3/4 inch NPTI cop-
per connection is more tolerable during installation and is 
more durable over time. The connection is rigidly mounted to 
assure proper fit and leak tight seal.

DURABLE FINISH - With a heavy duty cabinet made of pow-
der-painted, galvanized steel the neutral color blends into 
surrounding areas. The powdered paint, provides a better 
paint to steel bond, which resists corrosion and rust creep. 
The special primer formulas and glossy finish insure less fad-
ing when exposed to sunlight and offers a more attractive on 
site appearance. This paint finish meets ASTM-B117 stan-
dards for 750 hours salt spray rating. The highest in the 
industry.

FULL PERIMETER BASE RAILS - The easily removable 
base rails provide a solid foundation for the entire unit and 
protects the unit during shipment. The rails provide fork lift 
access from all sides, and rigging holes are also provided so 
that an overhead crane can be used to place the units on a 
roof. On applications where the unit is placed on a pad, the 
base will keep the unit off the pad to deter corrosion. On 
applications where height is limited, the inch high base rails 
may be removed on location.

MORE ATTRACTIVE APPEARANCE - A single piece Water 
Shed top cover containing a top discharge condenser fan 
arrangement requires less square footage on installation and 
provides a wider variety of installations. The one piece design 
adds greater water integrity. Rounded corners with water drip 
edges add to the attractive appearance. The cabinet panels 
have a non-fibrous insulation that will not release insulation 
fibers into conditioned area.

TOP DISCHARGE - The top discharge condenser fan does 
not disrupt neighboring areas or does this dry-out vegetation 
surrounding the unit. The warm air from the top mounted fan 
is blown up away from the structure and any landscaping. 
This allows compact location on multi-unit applications.

CONDENSER COIL GRILLE - A multi-piece totally enclosed, 
rigidly mounted condenser coil grille provides protection from 
objects after installation and provides protection during transit.

LOW OPERATING SOUND LEVEL - The upward air flow 
carries the normal operating noise up and away from the liv-
ing area. The rigid top panel effectively isolates any motor 
sound. Isolator mounted compressor and the rippled fins of 
the condenser coil muffle the normal fan motor and compres-
sor operating sounds. The unique formed base pan also aids 
in sound alterations with it’s Super-Structure design. This 
design strategically places embossments in the pan for opti-
mum strength and rigidity.

Summary of Contents for DNH018

Page 1: ...ibility and choices you need in today s market FEATURING COOLING GAS HEATING UNITS NATURAL GAS OR PROPANE LOW PROFILE QUIET OPERATION COMMON FOOTPRINT OPTIONAL SLIDE IN MOTORIZED DAMPERS OPTIONAL SLID...

Page 2: ...POWER SUPPLY 27 16 TYPICAL WIRING DIAGRAM 575 3 60 27 17 TYPICAL WIRING DIAGRAM LEGEND 28 18 WIRING DIAGRAM DETAIL B 460 575 3 60 POWER SUPPLY 29 LIST OF TABLES Tbl Pg 1 PHYSICAL DATA 6 2 RATINGS COOL...

Page 3: ...CONDENSATE PAN A non corrosive long lasting water tight pan is positioned below the evaporator coil to collect and drain all condensate Less collection of stagnate condensate will build up The conden...

Page 4: ...xter nally mounted re usable service access ports are provided on both the high and low lines for ease of evacuating and charging the system No final field mounting required EASY SERVICE ACCESS A larg...

Page 5: ...ns in each corner Kit also pro vides seal strip to assure a water tight seal 8 and 14 inch high roof curbs are available MANUAL OUTDOOR DAMPER Provides 0 through 50 outdoor air capability field adjust...

Page 6: ...TOTAL 1 800 2 200 2 400 2 400 2 400 3 000 3 000 CONDENSER COIL ROWS DEEP 1 1 1 2 1 2 2 FINS PER INCH 20 20 20 20 20 20 20 FACE AREA Sq Ft 11 7 11 7 11 7 11 7 14 7 14 7 14 7 CHARGE REFRIGERANT 22 lbs o...

Page 7: ...12 0 80 108 87 80 8 4 45 75 042N09025 42 0 12 0 80 108 87 80 8 4 45 75 042N09046 42 0 12 0 80 108 87 80 8 4 45 75 042N09058 42 0 12 0 80 108 87 80 8 4 45 75 048N06506 48 0 12 0 84 80 64 80 8 3 25 55 0...

Page 8: ...88 1 90 1 89 Sensible Capacity MBH 1 Entering Dry Bulb F 86 9 0 11 1 10 8 11 0 10 2 12 7 12 2 12 4 11 5 14 3 13 6 13 8 11 7 14 5 14 0 14 3 11 9 14 7 14 5 14 7 83 8 1 10 2 10 8 10 9 9 3 11 7 12 2 12 4...

Page 9: ...2 6 16 1 16 5 16 0 14 0 17 9 17 6 16 9 15 3 19 6 18 7 17 8 15 3 19 7 18 8 17 9 15 2 19 8 18 9 18 0 83 11 4 15 0 15 9 15 6 12 7 16 6 17 3 16 7 13 9 18 2 18 6 17 8 14 2 18 7 18 8 17 9 14 5 19 1 18 9 18...

Page 10: ...ty MBH 1 Entering Dry Bulb F 86 16 0 19 6 19 4 19 0 18 4 22 3 21 4 20 9 20 8 24 9 23 3 22 8 22 3 25 0 23 4 22 9 23 7 25 2 23 5 23 0 83 13 9 18 0 19 4 19 0 15 9 20 6 21 4 20 9 17 9 23 2 23 3 22 8 18 9...

Page 11: ...6 20 6 25 9 28 3 28 3 23 0 28 9 30 5 30 6 25 3 31 8 32 6 32 9 25 2 32 0 33 2 33 4 25 1 32 2 33 7 33 9 83 18 9 24 2 27 9 27 8 21 0 26 9 30 3 30 4 23 2 29 7 32 6 32 9 23 6 30 4 33 2 33 4 24 0 31 1 33 7...

Page 12: ...b F 86 24 8 31 0 29 9 29 5 28 2 34 9 32 7 32 2 31 6 38 7 35 5 35 0 34 0 39 1 36 2 34 8 36 3 39 4 35 0 34 5 83 21 8 28 0 29 9 29 5 24 7 31 6 32 7 32 2 27 5 35 3 35 5 35 0 29 3 36 8 35 2 34 8 31 1 38 4...

Page 13: ...86 31 8 39 0 39 9 39 9 34 3 41 4 40 8 40 7 36 9 43 8 41 6 41 5 40 3 45 7 42 8 42 8 43 8 47 6 44 1 44 0 83 28 4 35 7 38 9 39 0 30 3 38 0 40 2 40 3 32 2 40 3 41 6 41 5 35 0 43 3 42 8 42 8 37 9 46 2 44 1...

Page 14: ...86 41 8 51 8 53 0 51 7 43 6 54 0 53 8 52 6 45 5 56 2 54 6 53 4 47 1 56 7 54 3 56 1 48 7 57 3 54 0 52 8 83 36 9 47 0 52 2 51 7 38 4 48 9 53 4 52 6 39 9 50 7 54 6 53 4 41 2 52 3 54 3 53 1 42 5 53 8 54 0...

Page 15: ...977 477 LOW 1191 527 1149 510 1107 494 1065 477 1009 459 952 441 042 HI 1681 797 1610 768 1540 740 1465 712 1390 685 1315 657 1204 623 1093 588 MED 1432 650 1381 628 1330 605 1279 583 1210 556 1140 5...

Page 16: ...1075 534 LOW 1384 625 1336 605 1287 584 1239 564 1167 537 1094 509 048 HI 1906 982 1857 960 1809 938 1758 913 1706 888 1648 861 1590 834 1445 783 1301 731 MED 1734 848 1693 821 1651 794 1595 764 1539...

Page 17: ...500 961 474 LOW 1239 510 1184 496 1130 481 1075 467 998 448 922 428 042 HI 1687 763 1614 737 1540 712 1458 688 1377 663 1295 639 1147 600 MED 1482 628 1428 613 1374 599 1320 584 1242 556 1163 528 1085...

Page 18: ...163 2045 1125 1953 1085 1860 1045 1698 990 1535 935 MED 2159 1125 2098 1090 2036 1055 1967 1020 1897 985 1814 945 1731 905 1578 582 LOW 1937 990 1892 983 1846 935 1785 908 1723 880 1655 843 1587 805 0...

Page 19: ...rn air If the resistance of the return air duct system is less then 0 25 IWG the unit will deliver less CFM during full economizer operation R G W R G C Y Y W C PROGRAMMABLE THERMOSTAT ONLY Minimum wi...

Page 20: ...8 9 25 25 96 75 036 460 3 60 414 504 5 7 39 0 6 1 8 9 5 15 15 96 75 036 575 3 60 518 630 4 7 31 0 4 1 5 7 8 15 15 96 75 042 208 230 1 60 187 253 20 0 104 1 3 3 5 29 8 40 40 96 40 042 208 230 3 60 187...

Page 21: ...OVERALL All dimensions are in inches They are subject to change with out notice Certified dimensions will be provided upon request TABLE 17 UNIT DIMENSIONS FRONT UNIT SIZE DIMENSION A B 018 036 33 1 2...

Page 22: ...D R A I N 3 4 N P T I G A S S U P P L Y 1 5 8 D I A K N O C K O U T 1 2 N P T I C O N N E C T I O N L O W V O L T A G E C O N N 1 8 D I A K N O C K O U T 1 3 4 1 5 2 9 9 1 6 1 5 3 1 2 1 3 4 1 3 4 1 5...

Page 23: ...L G A S S H U T O F F V A L V E R E T U R N A I R D U C T S U P P L Y A I R D U C T C O N T R O L W I R I N G T O I N D O O R T H E R M O S T A T T O P O W E R S U P P Y M A N U A L G A S S H U T O F...

Page 24: ...O U N D I N S T A L L A T I O N TABLE 19 UNIT WEIGHTS AND CENTER OF GRAVITY UNIT SIZE SHIPPING WEIGHT lbs OPERATING WEIGHT lbs CORNER WEIGHTS location lbs ECONOMIZER lbs ROOF CURB lbs A B C D 018 365...

Page 25: ...1 8 X 2 1 1 2 R E C O M M E N D E D D U C T S I Z E 1 7 1 2 X 1 6 3 4 1 8 Roof curb also available 3 4 X 1 W I D E G A S K E T I N G F O R C U R B F R A M E A N D A L L D U C T S U P P O R T S U R F...

Page 26: ...roup FIGURE 13 TYPICAL WIRING DIAGRAM 208 230 1 60 POWER SUPPLY FIGURE 14 TYPICAL WIRING DIAGRAM 208 230 3 60 POWER SUPPLY SEE DETAIL A T2 M1 2 DETAIL A L 2 BLK BLK CCH L1 T1 OPTIONAL CCH S P CONFIGUR...

Page 27: ...036 21233 002 A 0903 Unitary Products Group 27 FIGURE 15 TYPICAL WIRING DIAGRAM 460 3 60 POWER SUPPLY FIGURE 16 TYPICAL WIRING DIAGRAM 575 3 60...

Page 28: ...ry wired for low or medium speed indoor blower operation to change motor speed connect speed tap wires from indoor blower motor per Detail B Figure 18 tape unused speed tap wires to prevent shorting a...

Page 29: ...ly mounted condenser coil guard to provide protection from objects and personnel after installation Indoor blower section shall be insulated with up to 3 4 thick aluminum foil faced insulation fastene...

Page 30: ...xpansion blow through design while condenser coil shall be draw through design Refrigerant Circuit and Refrigerant Safety Components a Shall include independent fixed orifice expansion devices b Shall...

Page 31: ...036 21233 002 A 0903 Unitary Products Group 31...

Page 32: ...o change without notice Printed in U S A 036 21233 002 A 0903 Copyright by Unitary Products Group 2003 All rights reserved Supersedes 036 21233 001 D 0603 Unitary 5005 Norman Products York OK Group Dr...

Reviews: