DESCRIPTION

Sunline™ 2000 series convertible package rooftop mod-
els have two independent refrigerant circuits for efficient
part load operation. Although the units are primarily
designed for curb mounting on a roof, they can also be
slab-mounted at ground level or set on steel beams above
a finished roof.

Cooling only, cooling with gas heat and cooling with electric
heat models are available with a wide variety of factory-
mounted options and field-installed accessories to make
them suitable for almost every application.

All units are self-contained and assembled on full perimeter
base rails with holes in the four corners for overhead
rigging.

Every unit is completely piped, wired, charged and tested
at the factory to simplify field installation and to provide
years of dependable operation. Powder paint cabinets pro-
vide an exceptionally durable finish with the 750 hour salt
spray process per ASTM-B117 test standard.

All models (including those with an economizer) are suit-
able for either bottom or horizontal duct connections. Mod-
els with power exhaust are suitable for bottom duct
connections only. For bottom duct, you remove the sheet
metal panels from the supply and return air openings
through the base of the unit. For horizontal duct, you
replace the supply and return air panels on the rear of the
unit with a side duct flange accessory.

All models are available with five different outdoor air
damper options:

• Single enthalpy economizer

• Differential (dual) enthalpy economizer

• Single enthalpy economizer with power exhaust

• Differential (dual) enthalpy economizer with

power exhaust

• Motorized outdoor air damper

A fixed outdoor air intake assembly is shipped in the return
air compartment of all units ordered without an economizer
or motorized outdoor air damper option. The assembly
includes a rain hood with a damper that can be set for 10,
15 or 25% outdoor air. With bottom duct connections, the
intake damper assembly should be mounted over the
opening in the return air panel. With horizontal ductwork, it
should be mounted on the return air duct.

Technical Guide

Summary of Contents for D2CE

Page 1: ...de an exceptionally durable finish with the 750 hour salt spray process per ASTM B117 test standard All models including those with an economizer are suit able for either bottom or horizontal duct con...

Page 2: ...knockout in the wiring panel on the front of the unit All internal factory wiring is color coded and numbered for ease in servicing and troubleshooting FACTORY INSTALLED OPTIONS ECONOMIZERS Interlock...

Page 3: ...assembly They re designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger sup ports ANTI RECYCLE TIMERS Two solid state timers prevent the compressors fr...

Page 4: ...w e r S u p p l y w i t h E l e c t r i c H e a t E L E C T R I C E L E C T R I C U N I T S E L E C T R I C H E A T E R L O C A T I O N O P T I O N A L E L E C T R I C E L E C T R I C U N I T S I 2 0...

Page 5: ...er Coil 105 F 115 F Total Cap 1 MBH Power Input2 KW SensibleCapacity1 MBH Total Cap 1 MBH Power Input2 KW SensibleCapacity1 MBH CFM WB F En ter ing Dry Bulb F En ter ing Dry Bulb F 86 83 80 77 74 71 6...

Page 6: ...resistances have been deducted from the total static pressure of the blower FACTORY SETTING 7500 CFM 8750 CFM 10000 CFM 11250 CFM 12500 CFM STANDARD DRIVE ACCESSORY DRIVE DCE300 BOT TOM DUCT CON NEC T...

Page 7: ...18 KW 25 36 KW 30 54 KW 35 72 KW 40 Accesso ries Roof Curb 185 BarometricDamper 45 Economizer MotorizedDamper Rain Hood 55 Economizer PowerExhaustRain Hood 90 Wood Skid 220 OPERATING WEIGHTS ELECTRICA...

Page 8: ...140 1365 1B5V94 9 7 9 5 1 7 16 5VX840 84 0 1 1All mo tors have a nomi nal speed of 1800 RPM a 1 15 serv ice fac tor and a solid base They can op er ate to the limit of their serv ice fac tor be cause...

Page 9: ...n o t r e q u i r e d o n u n i t s w i t h a s i n g l e s t a g e e l e c t r i c h e a t e r C O O L I N G H E A T I N G E L E C T R O N I C T H E R M O S T A T T H E R M O S T A T 1 T E R M I N A...

Page 10: ...H RAILS Shown separately to illustrate Bottom Duct openings Power and Gas Piping Connection locations 12 1 2 9 1 4 8 1 8 9 3 4 3 3 4 B POWER WIRING ENTRY A CONTROL WIRING ENTRY 92 CONDENSER COILS OPTI...

Page 11: ...he rear of the unit SUPPLY AIR RETURN AIR OUTDOOR AIR 5 1 8 18 5 8 27 3 4 29 5 8 15 TON 39 5 8 20 TON 40 1 2 OUTDOOR AIR COMPARTMENT ACCESS FILTER ACCESS 1 NPT FEMALE COND DRAIN CONNECTION DOT PLUG Fo...

Page 12: ...ized motor 4 Point Loads 6 Point Loads DCE UNIT 4 POINT LOADS LBS TOTAL A B C D 300 2 890 487 619 646 508 DCE UNIT 6 POINT LOADS LBS TOTAL A B C D E F 300 2 890 415 471 528 551 492 433 DCG UNIT 4 POIN...

Page 13: ...036 21359 001 B 0302 Unitary Products Group 13 BASE RAIL 3 56 3 69...

Page 14: ...036 21359 001 B 0302 14 Unitary Products Group...

Page 15: ...measuring ports shall be pro vided on the outside of the cabinet to allow accu rate air measurements of evaporator fan performance without removing panels or creating air by pass of the coils 7 Conden...

Page 16: ...spark ignition redundant main gas valve Ventor wheel shall be constructed of stainless steel for corrosion resistance 2 The heat exchanger shall be of the tubular type constructed of T1 40 aluminized...

Page 17: ...e outdoor and return air damper assembly to take in the design CFM of outdoor air to meet the mini mum ventilation requirement of the conditioned space during normal operation During economizer operat...

Page 18: ...pulley and belt for higher CFM and or static pressure require ments 9 WOOD SKID Allows unit to be handled with 90 forks 10 ECONOMIZER MOTORIZED DAMPER RAIN HOOD DCE CG300 only Contains all hood panels...

Page 19: ...036 21359 001 B 0302 Unitary Products Group 19...

Page 20: ...036 21359 001 B 0302 20 Unitary Products Group...

Page 21: ...036 21359 001 B 0302 Unitary Products Group 21...

Page 22: ...036 21359 001 B 0302 22 Unitary Products Group...

Page 23: ...036 21359 001 B 0302 Unitary Products Group 23...

Page 24: ...ge without notice Printed in U S A CD 6 21359 036 21359 001 B 0302 Copyright by Unitary Products Group 2002 All rights reserved Supersedes 036 21359 001 A 0302 Unitary 5005 Norman Products York OK Gro...

Reviews: