ACCESSORIES

PROPANE (LP) CONVERSION KIT - 

1NP0347 - All units

This accessory conversion kit may be used to convert natural
gas (N) units for propane (LP) operation. Conversions must
be made by qualified distributor or dealer personnel.

CONCENTRIC VENT TERMINATION -

 

1CT0302 (2")

1CT0303 (3")

For use through rooftop, sidewall. Allows combustion air to
enter and exhaust to exit through single common hole. Elimi-
nates unslightly elbows for a cleaner installation.

SIDEWALL VENT TERMINATION KIT - 

1HT0901 (3")
1HT0902 (2")

For use on sidewall, two-pipe installations only. Provide a
more attractive termination for locations where the terminal is
visable on the side of the home.

COMBUSTIBLE FLOOR BASE - 

1CB0317 - 17 1/2” Cabinet
1CB0321 - 21” Cabinet
1CB0324 - 24-1/2” Cabinet

COIL TRANSITION KIT - 

1TK0917 - 17-1/2” Furnace

1TK0921 - 21” Furnace

1TK0924 - 24-1/2” Furnace

These kits are required in downflow application when using
G*F* series coils. These kits are not required with MC/FC
series coils, but please ensure that the coil and furnace are
secured and that there are no air leaks.

CONDENSATE NEUTRALIZER KIT - 

1NK0301

Neutralizer cartidge has a 1/2" plastic tube fittings for installa-
tion in the drain line. Calcium carbonate refill media is also
avaiable from the Source 1 Parts (p/n 026-30228-000).

HIGH ALTITUDE PRESSURE SWITCHES - 

For installation where the altitude is less than 8,000 feet it is 
not required that the pressure switch be changed. For alti-
tudes above 8,000 feet see kits below. Conversion must be 
made by qualified distributor or dealer personnel.

1PS0507 - 060 MBH
1PS0508 - 080/1200 MBH
1PS0509 - 080/1600 MBH
1PS0510 - 100 MBH
1PS0511 - 120 MBH

ROOM THERMOSTATS 

- A wide selection of compatible

thermosets are available to provide optimum performance
and features for any installation.

1H/1C, manual change-over electronic non-programmable 
thermostat.

1H/1C, auto/manual changeover, electronic programmable,
deluxe 7-day, thermostat.

1H/1C, auto/manual changeover, electronic programmable.

* For the most current accessory information, refer to the
price book or consult factory.

Summary of Contents for AFFINITY PV9

Page 1: ...o stage inducer operation Provides increased comfort level very quiet unit opera tion Adjustable delay timer allows two stage operation with sin gle stage thermostat Compact easy to install ideal height 40 cabinet Blower off delay for cooling SEER improvement Easy to connect power control wiring Built in high level self diagnostics with fault code display Low unit amp requirement for easy replacem...

Page 2: ...NSATE DRAIN OPENING 1 3 4 HORIZONTAL CONDENSATE DRAIN OPENING 1 3 4 JUNCTION BOX HOLE 7 8 GAS PIPE ENTRY 1 1 2 CONDENSATE DRAIN HOLE 7 8 29 22 3 4 21 1 4 18 1 2 9 1 8 8 1 2 30 1 8 23 11 16 E FRONT A 40 DIMENSIONS Models Nominal CFM Cabinet Size Cabinet Dimension A in B in C in D in E IN PV9B12N060DH11 1200 B 17 1 2 16 1 4 15 1 3 4 2 3 8 PV9B12N080DH11 1200 B 17 1 2 16 1 4 15 1 3 4 2 3 8 PV9C16N080...

Page 3: ...A 1287 772 D A 1337 802 C C 1132 668 D C HIGH LOW HEAT CFM WITHOUT FILTERS PV9B12N060DH11 PV9B12N080DH11 Jumper Settings High Low High Low HEAT Tap ADJ Tap 1137 720 1386 962 A Any 974 625 1322 892 B Any 883 593 1250 849 C Any 825 561 1159 768 D Any PV9C16N080DH11 PV9C20N100DH11 Jumper Settings High Low High Low HEAT Tap ADJ Tap 1732 1173 1912 1237 A Any 1631 1110 1688 1079 B Any 1493 1008 1545 967...

Page 4: ...return air openings or return air opening size and add to the ESP from Step 2 to determine the total system static If total system static matches a ESP value in the airflow table i e 0 20 0 60 etc the system airflow corresponds to the intersection of the ESP column and Model Blower Speed row FILTER SIZES Input Output BTU H CFM Cabinet Size Top Return Filter in 60 56 1200 B 2 14 x 20 80 75 1200 B 2...

Page 5: ... O Reversing Valve Energized in Cool TWO STAGE AIR CONDITIONING Comfort Alert Interface HUM Dehumidification Open on Humidity Rise C 24 Volt Common C 24 Volt Common R 24 Volt Hot W2 Second Stage Heat G Fan Y2 Second Stage Cool E W1 First Stage Heat RC 24 Volt Hot Cool XFMR Y1 First Stage Cool R 24 Volt Hot Y Y2 Single Second Stage Cool Y2 Second Stage Cool Y First Stage Cool Y2 Second Stage Cool W...

Page 6: ...elay on furnace to OFF HM Humidistat BSG Bonnet Sensor Bonnet Sensor Optional BS Bonnet Sensor AUX Auxiliary Heat E W1 First Stage Auxiliary Heat E W1 First Stage Auxiliary Heat W Auxiliary Heat Y2 Second Stage Heat Cool DHM Dehumidistat HUM Dehumidification Open on Humidity Rise Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool Y 2 O Reversing Valve Energized in Cool L...

Page 7: ... coils These kits are not required with MC FC series coils but please ensure that the coil and furnace are secured and that there are no air leaks CONDENSATE NEUTRALIZER KIT 1NK0301 Neutralizer cartidge has a 1 2 plastic tube fittings for installa tion in the drain line Calcium carbonate refill media is also avaiable from the Source 1 Parts p n 026 30228 000 HIGH ALTITUDE PRESSURE SWITCHES For ins...

Page 8: ...ange without notice Printed in U S A 246785 YTG B 0407 Copyright by York International Corp 2007 All rights reserved Supersedes 246785 036 21636 002 Rev A 1205 Unitary 5005 Norman Products York OK Group Drive 73069 ...

Reviews: