background image

333495-YTG-D-0609

4

Johnson Controls Unitary Products

More Attractive Appearance

 - A single piece Water 

Shed top cover containing a top discharge condenser fan 
arrangement requires less square footage on installation 
and provides a wider variety of installations. The one 
piece design adds greater water integrity. Rounded 
corners with water drip edges add to the attractive 
appearance. The cabinet panels have a non-fibrous 
insulation that will not release insulation fibers into 
conditioned area.

Top Discharge

 - The top discharge condenser fan does 

not disrupt neighboring areas or dry-out vegetation 
surrounding the unit. The warm air from the top mounted 
fan is blown up away from the structure and any 
landscaping. This allows compact location on multi-unit 
applications.

Condenser Coil Grille

 - All 13 SEER models and 5 ton 

14 SEER/12EER models utilize a decorative “Wire Form” 
coil guard to provide impact protection against large 
objects. The remaining higher SEER models utilize a 
stamped “Louvered” design which provides superior 
impact protection against smaller objects during transit 
and after installation.

Low Operating Sound Level

 - The upward air flow 

carries the normal operating noise up and away from the 
living area. The rigid top panel effectively isolates any 
motor sound. Isolator mounted compressor and the 
rippled fins of the condenser coil muffle the normal fan 
motor and compressor operating sounds. The unique 
formed base pan also aids in sound alterations with it's 
Super-Structure design. This design strategically places 
embossments in the pan for optimum strength and rigidity.

Fan System

 - All models operate over a wide range of 

design conditions with an electrically commutated fan 
motor. These units easily match all types of applications 
and provide greater on site flexibility to match comfort 
requirement. The cooling speed is factory set and can be 
field adjusted to a second speed. The heating speed is 
factory set to maintain mid point rise at the units heating 
input, but can be field adjusted. This allows maximum 
comfort conditions.

Simple Control Circuit

 - A low voltage printed circuit 

board contains a diagnostic indicator light and a low 
voltage terminal strip. An additional set of pin connectors 
is also provided to simplify the field interface of external 
controls. Mate-n-lock plug connectors are used. The 
electrical control box is not located in the compressor 
compartment. The controls are mounted on a Control-Tilt 
control panel to allow the access cover to be removed for 
trouble shooting and maintenance without affecting the 
normal system operating pressures. All wiring internal to 
the unit is color/number coded.

Protected Compressor

 - The compressor is internally 

protected against high pressure and temperature. This is 
accomplished by the simultaneous operation of high 
pressure relief valve and a temperature sensor which 
protect the compressor if undesirable operating conditions 
occur.

Pressure Switches 

- High pressure and low pressure/

loss of charge switches standard in all units. When 
abnormal conditions are sensed through the pressure 
switches, the unit will lock out preventing any further 
operation until reset or problem is corrected. 

Exclusive Coil Design

 - Grooved copper tubes and 

enhanced aluminum fin construction improves heat 
transfer for maximum efficiency and durability.

Low Maintenance

 - Long life, permanently lubricated 

condenser and evaporator fan motor bearings need no 
annual maintenance adding greater reliability to the unit. 
Blower assembly can be easily cleaned by the unique 
Slip- Track slide-out blower assembly.

Secured Service Access Ports

 - Protected, externally 

mounted, re-usable service access ports are provided on 
both the high and low lines for ease of evacuating and 
charging the system. No final field mounting required.

Easy Service Access

 - A large, single panel covers the 

electrical and gas controls makes servicing easy. The 
blower compartment has an additional large panel with a 
built-in handle tab. Removing this panel will allow the 
blower assembly to slide-out for easy removal for 
maintenance and ease of trouble shooting.

Replacement Parts

 - The installer requires no special 

training to replace any of the components of these units 
and does not need to maintain an inventory of unique 
parts.

System Integration

 - Each unit has the internal ability to 

integrate an electronic air cleaner or humidifier to work in 
conjunction with the base unit.

Field Installed Accessories

Economizer Down Discharge/Supply Kit

 - Modulating 

integrated economizer provides simultaneous operation 
between the mechanical cooling and economizer 
operation. Independent blade design insures proper 
control and less than 1% leak rate. Includes hood and 
mesh bird screen filter integrated into the hood, dry bulb 
sensor and relief damper. Separate field accessories of 
single enthalpy and dual enthalpy are also available. A 
built-in barometric relief of 25% is provided.

Single Enthalpy Sensor

 - Sensor replaces dry bulb 

sensor standard in economizer kit. Provides improved 
economizer operation by sensing the dry bulb 
temperature from outdoors plus the enthalpy content of 
the outdoor air.

Dual Enthalpy Sensor

 - Additional sensor to single 

enthalpy sensor. Sensor senses both the return air 
temperature dry bulb and humidity in conjunction with the 
single enthalpy to determine the most economical mix. 
Single Enthalpy sensor also required.

Hail Guard Kit

 - Kit contains protective grilles made of 

expanded aluminum with full perimeter frame. Sloped 
hoods are also included to assure maximum protection.

Summary of Contents for Affinity BHZ024

Page 1: ...pumps are designed for outdoor installation Only utility and duct connections are required at the point of installation Field installed electric heater accessories are available to provide electric heat if required R 410A AFFINITY SERIES BHX BHQ AND BHZ MODELS 2 5 TON 60 Hertz Tested in accordance with ISO 9001 Certified Quality Management System ...

Page 2: ...s 75 Component Location Heat Pump Direct Drive Condenser Fan Motor Highly Efficient Enhanced Copper Tube Aluminum Fin Indoor Coil Highly Efficient Enhanced Copper Tube Aluminum Fin Outdoor Coil Decorative Protective Coil Guard See Features for details Direct Drive Blower Motor With Slide Out Blower Assembly Heavy Gauge Removable Base Rails High Efficiency Compressor Rigidly Mounted Long Lasting Po...

Page 3: ...turn application If a bottom supply bottom return application is desired you simply remove the two panels from the bottom of the unit and place them in the side supply side return duct openings No panel cutting is required and no accessory panel is necessary Convertible airflow design allows maximum field flexibility and minimum inventory Condensate Pan A non corrosive long lasting water tight pan...

Page 4: ...ssor The compressor is internally protected against high pressure and temperature This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur Pressure Switches High pressure and low pressure loss of charge switches standard in all units When abnormal conditions are sensed through th...

Page 5: ...gs refer to technical literature They shall have built in equal size field convertible duct connections for down discharge supply return or horizontal discharge supply return The units shall be factory wired piped charged with R 410A Refrigerant and factory tested prior to shipment All unit wiring shall be both numbered and color coded All units shall be manufactured in a facility certified to ISO...

Page 6: ...ternally enhanced copper tubes with all joints brazed b Evaporator coil shall be of the direct expansion blow through design while condenser coil shall be draw through design Refrigerant Circuit and Refrigerant Safety Components shall include a Shall include independent fixed orifice expansion devices b Shall include filter strainer to eliminate any foreign matter Electric Heating Section Field In...

Page 7: ...croll 1 spd Scroll 1 spd Scroll 1 spd Scroll 1 spd Quantity 1 1 1 1 1 1 CONDENSER COIL DATA Face area Sq Ft 12 9 12 9 12 9 16 4 16 4 16 4 Rows 1 1 2 2 2 2 Fins per inch 20 20 20 20 20 20 Tube diameter in 3 8 3 8 3 8 3 8 3 8 3 8 Refrigerant control Orifice Orifice Orifice Orifice Orifice TXV EVAPORATOR COIL DATA Face area Sq Ft 4 38 4 38 4 38 5 63 5 63 5 63 Rows 2 3 3 3 3 3 Fins per inch 15 13 15 1...

Page 8: ...30 1 60 187 252 125 208 230 3 60 187 252 125 460 3 60 432 504 125 BHX BHQ 208 230 1 60 187 252 115 208 230 3 60 187 252 115 460 3 60 432 504 115 042 3 5 BHZ BHQ 208 230 1 60 187 252 125 208 230 3 60 187 252 125 460 3 60 432 504 125 048 4 0 BHZ 208 230 1 60 187 252 125 208 230 3 60 187 252 125 460 3 60 432 504 125 BHX BHQ 208 230 1 60 187 252 115 208 230 3 60 187 252 115 460 3 60 432 504 115 060 5 ...

Page 9: ...4 14 0 9 5 1000 72 28 3 1 7 26 6 21 6 16 7 11 7 26 2 1 9 24 7 19 7 14 8 9 8 67 26 1 1 7 26 1 24 1 19 0 14 0 9 0 24 8 1 9 24 8 23 8 18 9 13 9 8 9 62 24 2 1 7 24 2 24 2 24 0 19 1 14 1 9 1 23 0 1 9 23 0 23 0 22 9 18 0 13 0 8 0 57 23 3 1 7 23 3 23 3 23 3 18 3 13 4 8 4 22 7 1 9 22 7 22 7 22 7 17 8 12 8 7 8 95 F 105 F 600 77 23 0 1 8 11 5 8 7 5 8 22 8 2 1 11 8 9 0 6 1 72 22 5 1 8 16 5 13 7 10 8 8 0 21 6...

Page 10: ...17 4 2 5 17 4 17 4 17 7 13 8 9 9 6 0 15 6 2 7 15 6 15 6 15 6 12 4 8 6 4 7 57 18 0 2 5 18 0 18 0 17 2 13 3 9 4 5 5 16 3 2 8 16 3 16 3 15 5 11 6 7 7 3 8 900 72 20 7 2 6 20 0 16 2 11 8 7 3 19 3 2 9 19 3 15 9 11 5 7 0 67 18 7 2 6 18 7 18 7 16 2 11 8 7 3 16 5 2 8 16 5 16 5 15 3 10 8 6 4 62 17 5 2 6 17 5 17 5 17 7 13 2 8 8 4 4 15 6 2 8 15 6 15 6 15 6 11 5 7 1 2 7 57 18 1 2 6 18 1 18 1 17 7 13 3 8 9 4 4 ...

Page 11: ...8 21 5 15 3 34 3 2 8 32 5 26 3 20 1 13 9 67 34 6 2 6 34 6 34 6 26 2 20 0 13 8 31 5 2 7 31 5 31 5 25 5 19 3 13 1 62 32 6 2 3 32 6 32 6 32 6 26 4 20 2 13 9 28 6 2 6 28 6 28 6 28 6 22 4 16 1 9 9 57 30 7 2 4 30 7 30 7 30 7 24 5 18 3 12 1 28 1 2 6 28 1 28 1 28 1 21 9 15 7 9 5 95 F 105 F 750 77 35 7 2 6 16 4 12 9 9 3 32 5 2 8 15 1 11 5 8 0 72 32 6 2 6 20 9 17 3 13 7 10 2 29 5 2 8 19 7 16 2 12 6 9 1 67 2...

Page 12: ... 2 22 2 22 2 22 0 17 1 12 3 7 4 20 7 3 5 20 7 20 7 20 5 15 6 10 8 5 9 57 20 3 3 3 20 3 20 3 20 1 15 3 10 4 5 6 17 4 3 6 17 4 17 4 17 2 12 4 7 5 2 6 1125 72 28 6 3 3 26 5 21 0 15 4 9 9 26 9 3 6 25 5 20 0 14 4 8 9 67 25 6 3 4 25 6 25 6 21 9 16 4 10 9 24 0 3 7 24 0 24 0 21 3 15 8 10 3 62 23 9 3 3 23 9 23 9 23 8 18 3 12 7 7 2 23 5 3 6 23 5 23 5 23 3 17 8 12 3 6 7 57 21 9 3 3 21 9 21 9 21 8 16 2 10 7 5...

Page 13: ...6 40 1 3 0 39 0 31 5 24 1 16 6 67 40 8 2 5 40 8 40 8 33 9 26 5 19 0 37 9 2 9 37 9 37 9 32 5 25 1 17 6 62 37 7 2 5 37 7 37 7 37 7 30 3 22 8 15 4 35 4 2 8 35 4 35 4 35 4 28 0 20 5 13 1 57 37 3 2 5 37 3 37 3 37 3 29 9 22 4 15 0 35 2 2 9 35 2 35 2 35 2 27 7 20 2 12 8 95 F 105 F 900 77 40 0 2 9 21 7 17 5 13 2 37 1 3 4 20 1 15 8 11 6 72 36 7 2 9 27 1 22 8 18 6 14 3 33 6 3 4 25 5 21 3 17 0 12 7 67 33 4 2...

Page 14: ...0 62 26 3 3 8 26 3 26 3 27 4 21 6 15 8 9 9 23 5 4 2 23 5 23 5 23 5 18 7 12 9 7 0 57 26 4 3 8 26 4 26 4 27 5 21 7 15 9 10 0 23 7 4 2 23 7 23 7 23 7 18 9 13 1 7 3 1350 72 31 3 4 0 30 7 25 2 18 6 12 0 28 1 4 4 28 1 23 3 16 6 10 0 67 27 5 3 9 27 5 27 5 25 2 18 6 11 9 24 1 4 3 24 1 24 1 23 3 16 6 10 0 62 26 4 3 9 26 4 26 4 27 0 20 3 13 7 7 1 23 4 4 3 23 4 23 4 23 4 17 2 10 6 4 0 57 26 5 3 9 26 5 26 5 2...

Page 15: ...8 47 5 3 5 42 8 34 1 25 4 16 7 67 44 4 3 3 44 4 43 6 34 9 26 2 17 5 44 1 3 5 44 1 43 0 34 3 25 6 16 9 62 43 6 3 2 43 6 43 6 43 6 34 9 26 2 17 5 41 6 3 4 41 6 41 6 41 6 32 9 24 2 15 5 57 43 1 3 2 43 1 43 1 43 6 34 9 26 2 17 5 42 2 3 4 42 2 42 2 42 2 33 5 24 8 16 1 95 F 105 F 1050 77 42 5 3 5 22 9 17 9 12 9 39 6 3 8 22 3 17 3 12 3 72 39 9 3 5 31 0 26 0 21 0 16 0 36 3 3 7 29 9 24 9 19 9 14 9 67 37 3 ...

Page 16: ... 0 62 29 4 4 3 29 4 29 4 31 2 24 4 17 6 10 8 25 8 4 7 25 8 25 8 27 3 20 5 13 7 6 9 57 30 6 4 3 30 6 30 6 31 3 24 5 17 7 10 9 26 7 4 8 26 7 26 7 27 9 21 1 14 3 7 5 1575 72 36 2 4 4 35 5 28 5 20 7 13 0 31 7 4 8 33 8 27 1 19 4 11 6 67 31 8 4 3 31 8 31 8 28 5 20 7 13 0 26 6 4 7 26 6 27 5 26 4 18 7 10 9 62 30 4 4 3 30 4 30 4 31 3 23 5 15 8 8 0 26 5 4 6 26 5 26 5 27 3 19 6 11 8 4 1 57 31 6 4 3 31 6 31 6...

Page 17: ... 54 0 4 2 50 0 40 5 31 0 21 5 67 54 3 3 8 54 3 54 3 43 7 34 2 24 7 49 7 4 1 49 7 49 7 41 0 31 5 22 0 62 47 9 3 8 47 9 47 9 47 9 38 4 28 9 19 4 45 4 4 0 45 4 45 4 45 4 35 9 26 4 16 9 57 49 1 3 8 49 1 49 1 49 1 39 6 30 1 20 6 45 9 3 8 45 9 45 9 45 9 36 4 26 9 17 4 95 F 105 F 1200 77 56 5 3 4 28 5 22 8 17 1 51 7 3 8 27 8 22 1 16 4 72 51 3 3 6 36 5 30 8 25 1 19 4 46 4 3 8 35 7 30 0 24 3 18 6 67 46 1 3...

Page 18: ...4 1 62 35 7 4 7 35 7 35 7 35 2 27 5 19 7 11 9 31 9 5 1 31 9 31 9 31 5 23 8 16 0 8 2 57 35 7 4 7 35 7 35 7 35 3 27 6 19 8 12 0 32 1 5 2 32 1 32 1 31 7 23 9 16 1 8 3 1800 72 42 1 5 0 40 8 33 3 24 4 15 6 37 9 5 4 37 9 31 6 22 6 13 7 67 36 5 4 9 36 5 36 5 32 6 23 8 14 9 32 1 5 2 32 1 32 1 30 4 21 5 12 5 62 35 9 4 8 35 9 35 9 35 7 26 8 18 0 9 1 32 4 5 2 32 4 32 4 32 2 23 2 14 2 5 3 57 36 0 4 8 36 0 36 ...

Page 19: ... 69 2 5 1 63 0 50 6 38 2 25 8 67 66 9 4 6 66 9 66 2 51 4 39 0 26 5 62 3 5 0 62 3 62 0 49 6 37 1 24 7 62 65 2 4 1 65 2 65 2 65 2 52 8 40 4 28 0 59 0 4 7 59 0 59 0 59 0 46 6 34 2 21 7 57 64 5 4 1 64 5 64 5 64 5 52 1 39 7 27 3 58 5 4 7 58 5 58 5 58 5 46 1 33 7 21 2 95 F 105 F 1500 77 63 3 5 5 31 1 24 0 16 9 57 8 5 8 29 5 22 4 15 3 72 59 7 5 2 43 2 36 1 29 0 21 9 53 8 5 6 40 0 32 9 25 8 18 7 67 56 1 4...

Page 20: ... 62 41 3 6 1 41 3 41 3 45 1 35 4 25 6 15 9 36 3 6 6 36 3 36 3 36 3 33 3 23 5 13 8 57 43 2 6 1 43 2 43 2 41 8 32 1 22 4 12 7 39 4 6 6 39 4 39 4 38 2 28 5 18 8 9 1 2250 72 50 7 6 5 48 8 38 3 27 2 16 2 45 8 7 0 45 8 36 0 25 0 13 9 67 46 1 6 3 46 1 46 1 37 9 26 9 15 8 40 7 6 9 40 7 40 7 34 4 23 3 12 3 62 42 6 6 2 42 6 42 6 44 5 33 4 22 3 11 3 37 9 6 7 37 9 37 9 37 9 30 1 19 1 8 0 57 44 6 6 2 44 6 44 6...

Page 21: ...00 10 92 13 40 16 61 20 73 26 06 32 93 KW 1 49 1 57 1 64 1 72 1 79 1 87 1 94 2 02 80 MBH 6 33 7 83 9 75 12 23 15 43 19 56 24 88 31 75 KW 1 67 1 74 1 82 1 89 1 97 2 04 2 12 2 19 030 2 5 750 55 MBH 12 14 13 95 16 07 18 55 21 46 24 87 28 85 33 52 KW 1 68 1 73 1 79 1 85 1 91 1 97 2 03 2 09 70 MBH 9 98 11 80 13 92 16 40 19 31 22 71 26 70 31 36 KW 1 95 2 01 2 07 2 13 2 19 2 25 2 31 2 36 80 MBH 9 05 10 8...

Page 22: ... 28 03 33 69 40 46 KW 2 44 2 61 2 77 2 94 3 11 3 28 3 45 3 62 042 3 5 1050 55 MBH 14 34 17 01 20 13 23 79 28 08 33 09 38 97 45 85 KW 2 20 2 43 2 66 2 89 3 12 3 34 3 57 3 80 70 MBH 14 60 17 27 20 39 24 05 28 34 33 36 39 23 46 11 KW 2 72 2 95 3 18 3 41 3 63 3 86 4 09 4 32 80 MBH 13 11 15 77 18 90 22 56 26 84 31 86 37 74 44 62 KW 3 13 3 35 3 58 3 81 4 04 4 27 4 49 4 72 1225 55 MBH 14 84 17 51 20 63 2...

Page 23: ... MBH 24 54 28 20 32 46 37 44 43 23 49 98 57 85 67 02 KW 3 12 3 34 3 56 3 79 4 01 4 23 4 45 4 67 70 MBH 22 90 26 57 30 83 35 80 41 60 48 35 56 21 65 38 KW 3 56 3 78 4 00 4 22 4 44 4 66 4 89 5 11 80 MBH 21 74 25 40 29 67 34 64 40 43 47 18 55 05 64 22 KW 4 07 4 30 4 52 4 74 4 96 5 18 5 40 5 62 1750 55 MBH 24 18 27 84 32 11 37 08 42 87 49 62 57 49 66 66 KW 3 20 3 42 3 64 3 86 4 08 4 31 4 53 4 75 70 MB...

Page 24: ...78 377 981 971 397 1048 Medium High 4 1416 413 872 1314 436 932 1206 454 993 1083 460 1051 High 5 1441 530 970 1326 538 1022 1182 521 1070 042 3 5 BHZ Low 1 1241 221 702 1151 245 778 1058 268 853 Low Medium 2 1406 299 759 1325 324 826 1242 349 893 1158 373 959 1072 396 1025 Medium 3 1536 376 808 1461 403 869 1384 427 928 1305 449 988 1223 468 1046 Medium High 4 1656 466 858 1584 492 912 1509 515 9...

Page 25: ...78 377 981 971 397 1048 Medium High 4 1416 413 872 1314 436 932 1206 454 993 1083 460 1051 High 5 1441 530 970 1326 538 1022 1182 521 1070 042 3 5 BHZ Low 1 1241 221 702 1151 245 778 1058 268 853 Low Medium 2 1406 299 759 1325 324 826 1242 349 893 1158 373 959 1072 396 1025 Medium 3 1536 376 808 1461 403 869 1384 427 928 1305 449 988 1223 468 1046 Medium High 4 1656 466 858 1584 492 912 1509 515 9...

Page 26: ...02 0 03 0 06 1300 0 07 0 03 0 17 036 3 0 BHZ BHX BHQ 700 0 01 0 00 0 02 0 03 800 0 01 0 01 0 02 0 03 900 0 01 0 01 0 02 0 04 1000 0 02 0 01 0 02 0 04 1100 0 03 0 01 0 03 0 05 1200 0 04 0 02 0 03 0 06 1300 0 04 0 03 0 03 0 07 1400 0 04 0 04 0 03 0 08 042 3 5 BHZ BHQ 1100 0 03 0 01 0 03 0 05 1200 0 04 0 02 0 03 0 06 1300 0 04 0 03 0 03 0 07 1400 0 04 0 04 0 03 0 08 1500 0 05 0 05 0 04 0 09 1600 0 06...

Page 27: ...1600 1600 208 230 3 60 1600 1600 1600 1600 460 3 60 1600 1600 1600 1600 BHX BHQ 208 230 1 60 1440 1440 1440 1440 208 230 3 60 1440 1440 1440 1440 460 3 60 1440 1440 1440 1440 060 5 0 BHZ 208 230 1 60 1750 1750 1750 1750 208 230 3 60 1750 1750 1750 1750 460 3 60 1750 1750 1750 1750 BHX BHQ 208 230 1 60 1900 1900 1900 1900 208 230 3 60 1900 1900 1900 1900 460 3 60 1900 1900 1900 1900 Indoor Blower S...

Page 28: ...500 1000 2000 4000 8000 024 2 0 BHZ 77 64 74 71 69 65 5 58 46 BHX BHQ 75 65 5 66 5 69 69 5 64 62 57 030 2 5 BHZ BHQ 77 65 66 5 72 71 5 68 5 65 5 64 5 036 3 0 BHZ 78 67 5 67 73 73 69 64 5 61 5 BHX BHQ 79 73 71 5 72 71 67 64 5 60 042 3 5 BHZ BHQ 77 64 5 67 71 5 72 5 69 5 64 5 59 048 4 0 BHZ 78 65 67 72 72 69 67 5 63 BHX BHQ 80 70 71 75 74 70 66 67 060 5 0 BHZ 85 70 72 5 79 79 5 76 73 5 73 BHX BHQ 80...

Page 29: ...46 15 1 18 32 7 35 042 3 5 208 230 1 60 18 6 105 29 1 2 6 0 None 30 5 40 2NP04501006 7 5 10 2 36 1 41 7 75 6 82 5 80 90 2NP04501506 11 3 15 2 54 2 62 5 98 2 108 6 100 110 2ND04501506 3 8 5 1 18 1 20 8 53 56 5 60 60 7 5 10 1 36 1 41 7 75 6 82 5 80 90 208 230 3 60 13 4 88 21 1 2 6 0 None 24 30 2NP04501025 7 5 10 1 20 8 24 1 50 54 60 60 2NP04501525 11 3 15 1 31 3 36 1 63 69 1 70 70 460 3 60 6 4 39 10...

Page 30: ...333495 YTG D 0609 Johnson Controls Unitary Products 63 Typical BHX BHQ BHZ024 060 Wiring Diagrams Typical BHX024 048 and 060 Heat Pump 208 230 1 60 volt Wiring Diagram ...

Page 31: ...333495 YTG D 0609 66 Johnson Controls Unitary Products Typical BHZ024 060 Heat Pump 208 230 1 60 volt Wiring Diagram ...

Page 32: ...333495 YTG D 0609 70 Johnson Controls Unitary Products Typical BHZ030 060 Heat Pump 230 3 60 volt Wiring Diagram ...

Page 33: ...333495 YTG D 0609 74 Johnson Controls Unitary Products Typical BHZ030 060 Heat Pump 460 3 60 volt Wiring Diagram ...

Page 34: ... 89 102 BHQ 405 400 22 25 25 109 95 92 105 BHX 405 400 21 75 24 25 108 90 92 110 042 3 5 BHZ 445 440 22 25 25 120 104 101 115 BHQ 425 420 22 25 25 114 100 96 110 048 4 0 BHZ 490 485 22 25 25 132 115 111 127 BHQ 445 440 22 25 25 120 104 101 115 BHX 445 440 22 26 126 107 95 112 060 5 0 BHZ 500 495 22 25 25 135 117 113 130 BHQ 495 490 22 25 26 137 122 109 122 BHX 465 460 22 26 25 133 113 99 116 X CEN...

Page 35: ...2 3 2 Units may be installed on combustable floors made from wood or class A B or C roof covering materials 3 Minimum Clearance of 1inch all sides of supply air duct for the first 3 foot of duct for 20 25 kW zero inches there after For all other heaters zero inch clearance all sides for entire length of duct 0 FRONT OVERALL OVERALL OVERALL COMPRESSOR SERVICE ACCESS COMPARTMENT PANEL REFRIGERANT CO...

Page 36: ...NECTION LOW VOLTAGE CONN 7 8 DIA KNOCKOUT 4 5 8 26 3 4 CONDENSATE DRAIN 3 4 NPTF HIGH VOLTAGE CONN 1 3 32 DIA KNOCKOUT LOW VOLTAGE CONN 7 8 DIA KNOCKOUT HIGH VOLTAGE CONN 1 31 32 x 7 8 KNOCKOUT 22 1 2 43 1 2 40 1 2 4 14 1 2 28 3 8 14 1 2 BACK 3 3 8 SIDE RETURN AIR OPENING 14 1 2 4 1 4 3 1 2 15 1 3 4 1 3 4 BOTTOM RETURN AIR OPENING 15 28 9 16 15 1 3 4 BOTTOM SUPPLY AIR OPENING CONDENSER COIL SIDE S...

Page 37: ...ions Unit Typical Slab on Ground Installation ROOF CURB INSTALLATION REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION TO POWER SUPPLY SUPPLY AIR DUCT RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH LOCATED TO REAR OF UNIT CONTROL WIRING TO INDOOR THERMOSTAT ...

Reviews: