292443-XTG-B-0807
Unitary Products Group
7
TABLE 3: DNA018 COOLING CAPACITIES - 1-1/2 TON
TEMPERATURE
OF AIR ON
CONDENSER COIL
AIR ON EVAPORATOR COIL
450 CFM
525 CFM
600 CFM
675 CFM
750 CFM
WB °F
WB °F
WB °F
WB °F
WB °F
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
85 °F
NET CAP.
MBH
17.4
16.6
15.3
15.3
18.3
17.4
16.1
16.0
19.1
18.2
16.8
16.8
19.6
18.7
17.2
17.2
20.1
19.2
17.7
17.6
TOTAL POWER
INPUT kW
1.78
1.77
1.72
1.75
1.81
1.80
1.75
1.78
1.83
1.83
1.77
1.81
1.85
1.84
1.79
1.82
1.86
1.86
1.80
1.84
Sen
s
ib
le Cap
a
city
MBH
1
En
te
ring Dry
Bu
lb °F
86
9.3
11.9
14.1
15.0
11.0
13.8
15.5
15.9
12.7
15.7
16.8
16.8
12.3
15.5
17.2
17.2
11.9
15.2
17.7
17.6
83
8.8
11.4
13.7
14.5
10.0
12.8
15.2
15.6
11.2
14.2
16.8
16.8
11.2
14.4
17.2
17.2
11.3
14.6
17.5
17.6
80
8.3
11.0
13.2
14.1
9.0
11.9
14.3
15.2
9.7
12.8
15.4
16.4
10.2
13.4
16.1
17.0
10.7
14.1
16.9
17.6
77
7.9
10.5
12.7
13.6
8.1
10.9
13.3
14.2
8.2
11.3
13.9
14.9
9.2
12.4
15.1
16.0
10.1
13.5
16.4
17.0
74
7.4
10.0
12.3
13.1
7.1
9.9
12.3
13.3
6.8
9.8
12.4
13.4
8.2
11.4
14.1
14.9
9.6
12.9
15.8
16.5
71
-
9.6
11.8
12.7
-
8.9
11.4
12.3
-
8.3
10.9
11.9
-
10.3
13.1
13.9
-
12.3
15.2
15.9
68
-
9.1
11.3
12.2
-
8.0
10.4
11.3
-
6.8
9.4
10.4
-
9.3
12.0
12.9
-
11.8
14.6
15.3
95 °F
NET CAP.
MBH
16.7
15.5
14.5
14.5
17.5
16.3
15.3
15.2
18.4
17.1
16.0
16.0
18.9
17.6
16.4
16.4
19.3
18.1
16.8
16.8
TOTAL POWER
INPUT kW
1.89
1.89
1.86
1.85
1.93
1.92
1.89
1.88
1.97
1.96
1.93
1.92
1.98
1.97
1.94
1.93
1.99
1.98
1.95
1.94
S
e
n
s
ib
le
C
apac
it
y
MB
H
1
Ent
e
ri
ng Dry
Bul
b
°
F
86
10.7
13.2
14.5
14.5
11.7
14.5
15.3
15.2
12.7
15.7
16.0
16.0
12.1
15.3
16.4
16.4
11.5
14.9
16.8
16.8
83
9.3
11.9
14.2
14.5
10.2
13.0
15.1
15.2
11.1
14.1
16.0
16.0
11.0
14.2
16.4
16.4
11.0
14.3
16.8
16.8
80
8.0
10.6
12.9
13.1
8.7
11.5
14.1
14.3
9.4
12.5
15.2
15.5
9.9
13.1
16.0
16.2
10.4
13.7
16.8
16.8
77
6.6
9.2
11.5
11.8
7.2
10.0
12.6
12.9
7.8
10.9
13.6
13.9
8.8
12.0
14.9
15.1
9.8
13.1
16.2
16.2
74
5.3
7.9
10.2
10.4
5.8
8.6
11.1
11.4
6.2
9.3
12.0
12.3
7.7
10.9
13.8
14.0
9.2
12.6
15.6
15.7
71
-
6.5
8.9
9.1
-
7.1
9.6
99.9
-
7.7
10.4
10.7
-
9.8
12.7
12.9
-
12.0
15.0
15.1
68
-
5.2
7.5
7.8
-
5.6
8.2
8.4
-
6.1
8.8
9.1
-
8.7
11.6
11.8
-
11.4
14.5
14.5
105 °F
NET CAP.
MBH
15.6
14.2
13.4
13.3
16.4
14.9
14.1
14.0
17.2
15.6
14.8
14.7
17.7
16.0
15.2
15.1
18.2
16.5
15.6
15.5
TOTAL POWER
INPUT kW
2.03
2.00
1.98
1.98
2.06
2.03
2.01
2.01
2.09
2.06
2.04
2.04
2.11
2.08
2.06
2.06
2.13
2.10
2.07
2.07
S
ensible
Cap
a
city
MBH
1
Ent
e
rin
g
Dr
y
Bulb
°
F
86
9.4
11.7
13.3
13.1
10.2
12.8
14.0
13.9
11.1
13.9
14.8
14.7
11.1
14.1
15.2
15.1
11.1
14.3
15.6
15.5
83
8.5
10.9
12.9
12.9
9.3
11.9
13.8
13.8
10.1
12.9
14.8
14.7
10.3
13.3
15.2
15.1
10.6
13.7
15.6
15.5
80
7.6
10.0
12.0
12.0
8.3
10.9
13.2
13.1
9.0
11.9
14.3
14.2
9.5
12.5
14.9
14.9
10.0
13.1
15.6
15.5
77
6.7
9.1
11.2
11.1
7.4
10.0
12.2
12.2
8.0
10.8
13.2
13.2
8.7
11.7
14.1
14.1
9.5
12.6
15.0
15.0
74
5.9
8.2
10.3
10.2
6.4
9.0
11.3
11.2
7.0
9.8
12.2
12.1
7.9
10.9
13.3
13.3
8.9
12.0
14.5
14.4
71
-
7.4
9.4
9.4
-
8.1
10.3
10.2
-
8.7
11.2
11.1
-
10.1
12.5
12.5
-
11.5
13.9
13.9
68
-
6.5
8.6
8.5
-
7.1
9.3
9.3
-
77.7
10.1
10.1
-
9.3
11.7
11.7
-
10.9
13.4
13.3
115 °F
NET CAP.
MBH
14.5
12.8
12.3
12.2
15.2
13.4
12.9
12.8
15.9
14.0
13.5
13.4
16.5
14.5
14.0
13.8
17.0
15.0
14.4
14.3
TOTAL POWER
INPUT kW
2.16
2.11
2.10
2.10
2.19
2.14
2.13
2.13
2.22
2.17
2.16
2.16
2.24
2.19
2.18
2.18
2.27
2.21
2.20
2.20
Se
nsible Cap
a
city
MBH
1
En
te
ri
n
g
D
ry
Bu
lb
°
F
86
8.1
10.2
12.0
11.7
8.8
11.2
12.8
12.5
9.6
12.2
13.5
13.4
10.2
12.9
14.0
13.8
10.7
13.6
14.4
14.3
83
7.7
9.8
11.6
11.3
8.4
10.8
12.6
12.3
9.1
11.7
13.5
13.4
9.7
12.4
14.0
13.8
10.2
13.1
14.4
14.3
80
7.3
9.4
11.2
10.9
7.9
10.3
12.3
11.9
8.6
11.2
13.3
12.9
9.1
11.9
13.9
13.9
9.7
12.6
14.4
14.3
77
6.9
9.0
10.8
10.5
7.5
9.9
11.8
11.5
8.2
10.8
12.9
12.5
8.6
11.4
13.4
13.1
9.1
12.0
13.9
13.7
74
6.5
8.6
10.4
10.1
7.1
9.5
11.4
11.0
7.7
10.3
12.4
12.0
8.1
10.9
12.9
12.6
8.6
11.5
13.3
13.2
71
-
8.2
10.0
9.7
-
9.0
10.9
10.6
-
9.8
11.9
11.5
-
10.4
12.3
12.1
-
10.9
12.8
12.7
68
-
7.8
9.6
9.2
-
8.6
10.5
10.1
-
9.3
11.4
11.0
-
9.9
11.8
11.6
-
10.4
12.3
12.1
125 °F
NET CAP.
MBH
13.5
11.4
11.2
11.1
14.1
11.9
11.7
11.6
14.7
12.5
12.3
12.1
15.3
12.9
12.7
12.6
15.9
13.4
13.2
13.0
TOTAL POWER
INPUT kW
2.30
2.23
2.22
2.23
2.32
2.25
2.25
2.26
2.35
2.27
2.27
2.28
2.38
2.30
2.30
2.31
2.41
2.33
2.33
2.34
Sen
s
ib
le Cap
a
city
MB
H
1
En
te
ring Dry
Bu
lb °F
86
6.8
8.7
10.8
10.3
7.4
9.6
11.5
11.2
8.1
10.5
12.3
12.1
9.2
11.7
12.7
12.6
10.3
13.0
13.2
13.0
83
6.8
8.8
10.3
9.7
7.5
9.7
11.3
10.9
8.2
10.5
12.3
12.1
9.0
11.5
12.7
12.6
9.8
12.5
13.2
13.0
80
6.9
8.9
10.4
9.7
4.6
9.8
11.4
10.7
8.2
10.6
12.4
11.6
8.8
11.3
12.8
12.3
9.3
12.0
13.2
13.0
77
7.0
9.0
10.4
9.8
7.6
9.8
11.4
10.8
8.3
10.7
12.5
11.7
8.5
11.1
12.6
12.1
8.8
11.5
12.7
12.5
74
7.0
9.0
10.5
9.9
7.7
9.9
11.5
10.8
8.4
10.8
12.5
11.8
8.3
10.9
12.4
11.9
8.2
10.9
12.2
12.0
71
-
9.1
10.6
9.9
-
10.0
11.6
10.9
-
10.9
12.6
11.9
-
10.6
12.2
11.7
-
10.4
11.7
11.5
68
-
9.2
10.6
10.0
-
10.1
11.7
11.0
-
11.0
12.7
12.0
-
10.4
11.9
11.4
-
9.9
11.2
10.9
1. These capacities are net capacities (the indoor fan heat is deducted).
ALL SENSIBLE CAPACITY