292443-XTG-B-0807
4
Unitary Products Group
FAN SYSTEM
- All models operate over a wide range of
design conditions with a 3-speed direct-drive fan motor.
These units easily match all types of applications and pro-
vides greater on site flexibility to match comfort requirement.
SIMPLE CONTROL CIRCUIT
- A low voltage printed circuit
board contains a diagnostic indicator light and a low voltage
terminal strip. An additional set of pin connectors is also pro-
vided to simplify the field interface of external controls. Mate-
n-lock plug connectors are used. The electrical control box is
not located in the compressor compartment. The controls are
mounted on a Control-Tilt control panel to allow the access
cover to be removed for trouble shooting and maintenance
without affecting the normal system operating pressures. All
wiring internal to the unit is color/number coded.
PROTECTED COMPRESSOR
- The compressor is internally
protected against high pressure and temperature. This is
accomplished by the simultaneous operation of high pressure
relief valve and a temperature sensor which protect the com-
pressor if undesirable operating conditions occur.
EXCLUSIVE COIL DESIGN
- Grooved copper tubes and
enhanced aluminum fin construction improves heat transfer
for maximum efficiency and durability.
HEAT EXCHANGERS
- Are corrosion-resistant, aluminized-
steel tubular construction to provide long-life, trouble-free
operation. The unique blow-through design also assures that
condensate does not collect in humid areas when in the cool-
ing cycle. This adds to longer heat exchanger life and higher
long term efficiencies.
POST PURGE INDUCED DRAFT COMBUSTION
- Exhausts
combustion products from the heat exchanger upon comple-
tion of the heating cycle to prolong the heat exchanger life.
SELF DIAGNOSTIC FAN CONTROL MODULE
- Due to this
self diagnostic control, less on site time is required to trouble
shoot these units.
SPARK TO PILOT IGNITION
- Provides faster heat delivery.
This ignition is highly reliable, durable and eliminates nui-
sance lockouts.
MULTI PORT IN-SHOT BURNERS
- No field adjustment is
required to mix the air and gas. These burners are con-
structed of high-grade corrosion-resistant, aluminized-steel.
LOW MAINTENANCE
- Long life, permanently lubricated
condenser and evaporator fan motor bearings need no
annual maintenance adding greater reliability to the unit.
Blower assembly can be easily cleaned by the unique Slip-
Track slide-out blower assembly.
SECURED SERVICE ACCESS PORTS
- Protected, exter-
nally mounted, re-usable service access ports are provided
on both the high and low lines for ease of evacuating and
charging the system. No final field mounting required.
EASY SERVICE ACCESS
- A large, single panel covers the
electrical and gas controls makes servicing easy. The blower
compartment has an additional large panel with a built-in
handle tab. Removing this panel will allow the blower assem-
bly to slide-out for easy removal for maintenance and ease of
trouble shooting.
REPLACEMENT PARTS
- The installer has no need to carry
an inventory of unique parts or needs special training to
replace any of the components parts for these units. All are
easily obtained from Source 1 or other part houses.
SYSTEM INTEGRATION
- Each unit has the internal ability
to integrate an electronic air cleaner or humidifier to work in
conjunction with the base unit.
FIELD-INSTALLED ACCESSORIES
PROPANE CONVERSION KIT
- Kit includes burner orifices,
gas valve conversion and installation instructions necessary
to field convert unit from natural gas to propane.
HIGH ALTITUDE CONVERSION KIT
(Natural Gas/Propane)
- Kit includes all necessary labels and instructions to field
alter units with natural gas/propane for installation above
2000 feet. Burner orifices must be obtained from Source 1
Parts. Propane Conversion Kit must be obtained separately.
ECONOMIZER DOWN DISCHARGE / SUPPLY KIT
- Modu-
lating integrated economizer provides simultaneous opera-
tion between the mechanical cooling and economizer
operation. Independent blade design insures proper control
and less than 1% leak rate. Includes hood and mesh bird
screen filter integrated into the hood, dry bulb sensor and
relief damper. Separate field accessories of single enthalpy
and dual enthalpy are also available. A built-in barometric
relief of 25% is provided.
SINGLE ENTHALPY SENSOR
- Sensor replaces dry bulb
sensor standard in economizer kit. Provides improved econo-
mizer operation by sensing the dry bulb temperature from
outdoors plus the enthalpy content of the outdoor air.
DUAL ENTHALPY SENSOR
- Additional sensor to single
enthalpy sensor. Sensor senses both the return air tempera-
ture dry bulb and humidity in conjunction with the single
enthalpy to determine the most economical mix. Single
Enthalpy sensor also required.
PRESSURE SWITCH UPGRADE KIT
- Contains screw in
type High pressure, Low Pressure/Loss of Charge switch,
freeze protection switch and lockout relay. Switches are
placed onto existing scharder ports located in the unit by fur-
nished adapters. When abnormal conditions are sensed
through the pressure switches, the unit will lock out prevent-
ing any further operation until reset or problem is corrected.
Package agency approved.
HAIL GUARD KIT
- Kit contains protective grilles made of
expanded aluminum with full perimeter frame. Sloped hoods
are also included to assure maximum protection.
ANTI SHORT CYCLE TIMER
- Automatically prevents the
compressor from restarting for 5 minutes after cycled off.Not