background image

035-17737-003 Rev. A (0504)

8

Unitary Products Group

SECTION III: REPLACEMENT PARTS LIST

11

5

1

15

16

3

14

4

2

6

10

9

12

13

7

32

27

54

40

25

52

21

26

29

38

34

35

30

46

22

20

62

17

57

51

59

64

61

55

41

65

48

45

24

63

23

14

58

19

9

37

28

6

30

39 ,42

53

31

33

10

41

36

50

Summary of Contents for 92% GF9

Page 1: ...wet or the furnace if deemed necessary FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other...

Page 2: ...nace casing making sure the physical support is sound without sagging cracks or gaps Examine the furnace base making sure it is physically sound without cracks gaps or sagging and has a good seal 5 Ex...

Page 3: ...es to clear out any gas If you then smell gas STOP Follow B in the safety information above If you don t smell gas go to next step 7 Move gas control switch to the ON position Do not force See Figure...

Page 4: ...e cabinet Some installations may have the air filter in a rack attached to the cas ing of the furnace or placed in the return air duct If the filter location or replacement process is not obvious cont...

Page 5: ...nue until the thermostat circuit between R and W is opened which causes the ignition system and gas valve to de energize and the burner flames to be extinguished The vent motor will operate for an add...

Page 6: ...em by setting the thermostat above the room temperature Observe the system s response Then use the troubleshooting section in this manual to check the system s operation FURNACE CONTROL DIAGNOSTICS Th...

Page 7: ...s 6 7 8 will be reset This provides protection to an unoccupied structure if a temporary condition exists causing a furnace malfunction An example would be a low incoming gas supply pressure preventin...

Page 8: ...ry Products Group SECTION III REPLACEMENT PARTS LIST 11 5 1 15 16 3 14 4 2 6 10 9 12 13 7 32 27 54 40 25 52 21 26 29 38 34 35 30 46 22 20 62 17 57 51 59 64 61 55 41 65 48 45 24 63 23 14 58 19 9 37 28...

Page 9: ...ay 188 ID 2 ft req d 41 TUBING SILICONE Clear with insert 1 3 ft req d 42 GASKET AIR INTAKE 43 GASKET COMBUSTION BLOWER 44 GASKET CONDENSATE PAN 45 GASKET UPPER CONDENSATE PAN 46 GASKET GAS CONTROLS 4...

Page 10: ...R0324 1NK0301 CONDENSATE NEUTRALIZER KIT 1SF0101 EXTERNAL SIDE RETURN FILTER RACK GF9 ONLY REPLACEMENT PART CONTACT INFORMATION This is a generic parts list To request a complete parts list refer to t...

Page 11: ...035 17737 003 Rev A 0504 Unitary Products Group 11 SECTION IV WIRING DIAGRAM FIGURE 8 Wiring Diagram...

Page 12: ...s only to products installed in the United States and Canada EXCLUSIONS This warranty does not cover any 1 Shipping labor or material charges 2 Damages resulting from transportation installation or se...

Reviews: