background image

898147-UUM-B-0713

Johnson Controls Unitary Products

9

Limited Warranty

WARRANTY TERMS: 

Johnson Controls Unitary Products (hereinafter 

Company

) warrants this product to be free from defects in factory workman-

ship and material under normal use and service and will, at its option, repair or replace any parts, without charge, subject to the exclusions below,
that prove to have such defects according to the terms outlined in this warranty. Company reserves the right, at its sole discretion, to provide a
replacement unit in the place of repair parts, in which case the warranty period for the replacement unit is limited to the remainder of the original war-
ranty period. Alternatively, Company may, at its option, extend a replacement allowance to be applied toward the purchase of a new unit marketed by
Company. The exact amount of the allowance will be determined at the discretion of Company, based upon current market conditions, but in no case
shall this allowance exceed thirty (30) percent of the original consumer purchase price of the unit excluding such items as ductwork, wiring, piping,
and installation costs. The warranty period for repair or replacement parts or unit provided hereunder shall not extend beyond the warranty period
stated below. Company shall have no responsibility hereunder for installation, shipping, handling, or other charges except as specifically provided
herein.
This warranty covers only the equipment described by the Product Model Number and Unit Serial Number on the equipment or listed on the War-
ranty Registration Card, and applies only to products installed in the United States, Canada, or Puerto Rico. Tampering, altering, defacing, or remov-
ing the product serial number will serve to void this warranty. This warranty extends only to the original consumer purchaser and is nontransferable.
For this warranty to apply, the product must be installed according to Company recommendations and specifications, and in accordance with all
local, state, and national codes; and the product or residence must not be removed from its place of original installation. This warranty does not apply
to any unit sold over the Internet, by telephone or other electronic means unless the dealer that buys or sells a unit over the Internet, by telephone or
other electronic means also installs the unit. In the absence of a recorded Warranty Registration Card, the warranty period will begin upon product
shipment from Company. If you are unaware of the date the warranty became effective, contact Company at (877) 874-7378 or visit www.upgproduc-
tregistration.com. 

ADDITIONAL CONDITIONS FOR HEAT EXCHANGER WARRANTY:

 This warranty shall cover the heat exchanger (primary and/or secondary, if

applicable) only if:

1. The product has not been operated with an input rate in excess of the rating plate attached to the product.
2. The product has not been allowed to operate without the use of the proper automatic limit control on the maximum warm air temperature
and/or without adequate circulation.
3. The product is installed so that the combustion air is not contaminated by compounds of chlorine, fluorine, or other damaging chemicals
(or vapors).
4. The product is installed such that the heat exchangers are not exposed to return air temperatures below stated ratings.

FOR PRODUCT REGISTRATION: 

For your benefit and protection, register your product with Company promptly after installation. This will initiate

the warranty period and allow us to contact you, should it become necessary. You can register your product online at www.upgproductregistra-
tion.com or by returning the Warranty Registration Card on the back page of this packet.

FOR WARRANTY SERVICE OR REPAIR: 

Notify your Installing Dealer or a Participating Dealer, preferably in writing, as soon as possible after dis-

covery of the problem. Be sure to include the Product Model Number, Unit Serial Number, Installation Date, and a description of the problem. You
may find the Installing Dealer's name on this page or on the equipment, and you can locate Participating Dealers online at www.yorkupg.com.

If a Dealer response is not received within a reasonable amount of time, notify Company at: Johnson Controls Unitary Products, Consumer Rela-
tions, 5005 York Drive, Norman, OK 73069 or by telephone at (877) 874-7378. All warranty service or repair will be performed during regular busi-
ness hours, Monday through Friday 9:00 AM - 5:00 PM. Service requests sent to Company without prior Dealer contact will be referred back to a
Participating Dealer. Because this process takes time, it is in the best interest of the Consumer to contact a Participating Dealer directly.

WARRANTY PERIOD: The warranty period in years, depending on the part, is as shown in the chart below.

MAINTENANCE: 

Company strongly recommends regular periodic preventive maintenance on this equipment. The person most familiar with the

equipment in your HVAC system is a Participating Dealer. The Participating Dealer can ensure that your maintenance program meets the “Company
Warranty” conditions, maximize the equipment efficiency, and service your unit within the mandated guidelines with regard to unlawful discharge of
refrigerants into the atmosphere.

Product Model Number: _________________________________

Unit Serial Number: ____________________________________

Installation Date: _________________________________

Installing Dealer: _________________________________

CONDENSING UNITS

CONDENSING UNITS 

COMPRESSOR

PARTS

ALL MODELS

6 years

2 years

Summary of Contents for 16 SEER

Page 1: ...this manual before you start operating your new ductless system After reading this manual if you still need more information that may not have been covered in this manual please contact your HVAC cont...

Page 2: ...than R 22 Failure to use R 410A approved service equipment could result in equip ment explosion which could result in death or serious injury The refrigerant provided by the manufacturer complies with...

Page 3: ...y The unit will go into Auto Defrost mode and the heating will be discontinued for 8 to 10 minutes When the defrost cycle is complete the system will start running in heating mode While the outdoor un...

Page 4: ...UNIT ONE TO TWO ZONES 24 KBTU OUTDOOR UNIT TWO TO THREE ZONES 30 KBTU OUTDOOR UNIT TWO TO FOUR ZONES 42 KBTU OUTDOOR UNIT TWO TO FIVE ZONES AIR IN AIR OUT 1 2 3 8 4 5 7 6 1 Front Panel 2 Filter 3 Gui...

Page 5: ...ight with the indoor unit infrared receiver Make sure that there are no obstructions between the indoor unit receiver and the remote control when I FEEL feature is activated SWITCH FROM C TO F With sy...

Page 6: ...n AUTO mode 4 Keep pressing FAN button to select desired fan speed Fan speed selection is as fol low AUTO FAN LOW MID and HIGH 5 Press button to activate the swinging louver Press again to select a de...

Page 7: ...e healthy filter to the air filter as shown in Fig B Install the air filter properly as shown in Fig C and then close the panel CLEANING AND MAINTENANCE Remove the healthy filter and clean thoroughly...

Page 8: ...correct Are either the air inlet or air outlet blocked on the outdoor or indoor unit Is filter dirty Is fan at low speed Are windows and doors properly shut Wireless remote is not working Is remote in...

Page 9: ...anty shall cover the heat exchanger primary and or secondary if applicable only if 1 The product has not been operated with an input rate in excess of the rating plate attached to the product 2 The pr...

Page 10: ...n of the water circuit by foreign material or like causes 13 Damages caused by improper parts components or accessories not suitable for use in or with the unit For a list of parts that are known to b...

Reviews: