Johnson Controls Unitary Products

SAFETY

DUCTLESS SYSTEM DEFFINITIONS

SINGLE SPLIT SYSTEM

A single split system consists of a single outdoor unit and a single
indoor unit. The single split system is controlled using a remote control
(included with indoor unit).

MULTI-SPLIT SYSTEM

A multi-zone system consists of a single outdoor unit and two to five
indoor units. Each zone is controlled separately by a remote control
(included with the indoor unit).

EQUIPMENT MODEL NUMBERS

ELECTRICAL SHOCK, FIRE, OR EXPLOSION HAZARD.

• This product must be installed and serviced by a qualified

installer or service agency. Improper or incomplete installation,
adjustment, alteration, service or maintenance could cause per-
sonal injury, loss of life, or damage to property. Installation and
service must be performed by a licensed professional dealer or
contractor.

• Failure to follow safety warnings exactly could result in danger-

ous operation, serious injury, death or property damage.

• When servicing your ductless system, your HVAC contractor

must use factory supplied service and replacement parts. Failure
to follow these instructions may result in property damages such
as fire, personal injury or death. The manufacturer or seller can-
not be responsible for the interpretation of this information, nor
can it assume any liability in connection with its use.

• The power supply must be of proper amperage and conform with

local codes.

• Don't cut or damage the power cords and control cords. Electric

shock or fire could result. If they are damaged, immediately call
your HVAC contractor to have your ductless system serviced.

• Do not operate your ductless system without the air filter

installed. The air filter should be removed and cleaned periodi-
cally to assure maximum efficiency.

• If a burning smell or smoke occurs, please turn off the power

supply immediately and contact your HVAC contractor. Not doing
so may cause electric shock or fire.

• Do not use flammable sprays near your ductless system. They

can cause a fire or explosion.

• R410A Refrigerant High Pressure Warning!

The units described in this manual use R410A refrigerant which
operates at 50 to 70% higher pressures than R-22. Failure to
use R-410A approved service equipment could result in equip-
ment explosion which could result in death or serious injury.

• The refrigerant provided by the manufacturer complies with all

the requirements of this system. When using recycled or repro-
cessed refrigerant, its quality has to be as good as that of a new
refrigerant. It is necessary to have the recycled or reprocessed
refrigerant tested by a qualified laboratory. Failure to do so could
void the warranty.

• Grounding your ductless system is required!

Follow proper local electrical code on requirements for ground-
ing. Failure to follow code could result in death or serious injury.

• Do not use this system if it has been in a flooded area and under-

water. Call a licensed HVAC professional to inspect the system
and replace controls and electrical components that have been
damaged or replace the system, if determined necessary.

• Keep combustible materials at least 3 feet away from either the

indoor or outdoor unit. 

• Do not insert your hands, tools or any other item into the air

intake or air outlet at either the indoor or outdoor unit. 

• If outdoor unit is installed on a raised stand, check condition of

stand occasionally to ensure its stability. 

TABLE 1: 

OUTDOOR MODEL NUMBER

INDOOR MODEL NUMBER

LX 16 SEER Single Split Cooling Only Model Numbers

DCMF09CSM42Q1

DCMF09NWM42Q1

DCMF12CSM42Q1

DCMF12NWM42Q1

DCMF18CSM42Q1

DCMF18NWM42Q1

DCMF24CSM42Q1

DCMF24NWM42Q1

LX 16 SEER Single Split Heat Pump Model Numbers

DHMF09CSM42Q1

DHMF09NWM42Q1

DHMF12CSM42Q1

DHMF12NWM42Q1

DHMF18CSM42Q1

DHMF18NWM42Q1

DHMF24CSM42Q1

DHMF24NWM42Q1

Premium 22 SEER Single Split Cooling Only Model Numbers

DCPM09CSM41Q1

DCPM09NWM41Q1

DCPM09CSM42Q1

DCPM09NWM42Q1

DCPM12CSM41Q1

DCPM12NWM41Q1

DCPM12CSM42Q1

DCPM12NWM42Q1

DCPM18CSM42Q1

DCPM18NWM42Q1

DCPM24CSM42Q1

DCPM24NWM42Q1

DCPM36CSM42Q1

DCPM36NWM42Q1

Premium 22 SEER Single Split Heat Pump Model Numbers

DHPM09CSM41Q1

DHPM09NWM41Q1

DHPM09CSM42Q1

DHPM09NWM42Q1

DHPM12CSM41Q1

DHPM12NWM41Q1

DHPM12CSM42Q1

DHPM12NWM42Q1

DHPM18CSM42Q1

DHPM18NWM42Q1

DHPM24CSM42Q1

DHPM24NWM42Q1

DHPM30CSM42Q1

DHPM30NWM42Q1

DHPM36CSM42Q1

DHPM36NWM42Q1

LX 16 SEER Multi-Splits Heat Pump Outdoor Unit Model Numbers 

DHMF18CMM42Q1

\

DHMF24CMM42Q1

\

DHMF30CMM42Q1

\

DHMF36CMM42Q1

\

DHMF42CMM42Q1

\

LX 16 SEER Multi-Splits Heat Pump Indoor Unit Model Numbers 

\

DHPM09NWM42Q1

\

DHPM12NWM42Q1

\

DHPM18NWM42Q1

Summary of Contents for 16 SEER

Page 1: ...this manual before you start operating your new ductless system After reading this manual if you still need more information that may not have been covered in this manual please contact your HVAC cont...

Page 2: ...than R 22 Failure to use R 410A approved service equipment could result in equip ment explosion which could result in death or serious injury The refrigerant provided by the manufacturer complies with...

Page 3: ...y The unit will go into Auto Defrost mode and the heating will be discontinued for 8 to 10 minutes When the defrost cycle is complete the system will start running in heating mode While the outdoor un...

Page 4: ...UNIT ONE TO TWO ZONES 24 KBTU OUTDOOR UNIT TWO TO THREE ZONES 30 KBTU OUTDOOR UNIT TWO TO FOUR ZONES 42 KBTU OUTDOOR UNIT TWO TO FIVE ZONES AIR IN AIR OUT 1 2 3 8 4 5 7 6 1 Front Panel 2 Filter 3 Gui...

Page 5: ...ight with the indoor unit infrared receiver Make sure that there are no obstructions between the indoor unit receiver and the remote control when I FEEL feature is activated SWITCH FROM C TO F With sy...

Page 6: ...n AUTO mode 4 Keep pressing FAN button to select desired fan speed Fan speed selection is as fol low AUTO FAN LOW MID and HIGH 5 Press button to activate the swinging louver Press again to select a de...

Page 7: ...e healthy filter to the air filter as shown in Fig B Install the air filter properly as shown in Fig C and then close the panel CLEANING AND MAINTENANCE Remove the healthy filter and clean thoroughly...

Page 8: ...correct Are either the air inlet or air outlet blocked on the outdoor or indoor unit Is filter dirty Is fan at low speed Are windows and doors properly shut Wireless remote is not working Is remote in...

Page 9: ...anty shall cover the heat exchanger primary and or secondary if applicable only if 1 The product has not been operated with an input rate in excess of the rating plate attached to the product 2 The pr...

Page 10: ...n of the water circuit by foreign material or like causes 13 Damages caused by improper parts components or accessories not suitable for use in or with the unit For a list of parts that are known to b...

Reviews: