The defrost mode is equivalent to the cooling mode except that the out-
door fan motor is de-energized. The control shall do the following to ini-
tiate a defrost cycle.

De-energize the outdoor fan.

Energize the reversing valve.

Energize the auxiliary heat output through the Wout terminal.

Begin the maximum defrost cycle length timer.

If the call for heating (Y) is removed from the control during the defrost
cycle, it will terminate the defrost cycle and de-energize the compres-
sor. The control will also stop the defrost cycle length timer but not reset
it. When the control receives another call for heating, it will restart the
defrost cycle and the timer at the point at which the call for heating was
removed. This will happen only if the coil sensor temperature conditions
allow defrost to occur.

Defrost Curves

The control uses a set of defrost curve parameters that are selected
using the defrost curve selection jumper. The location of the defrost
curve selection jumper is shown on the Tabular Data sheet for each
heat pump model.

Defrost Curve Selection

The second page of the tabular data sheet indicates the proper jumper
setting for the specific heat pump model.

The control only reads the jumper input when the Y and W thermostat
inputs are de-energized. If a jumper position is changed while either of
these inputs is energized, the control will not act upon the jumper
changes until the thermostat calls are de-energized or power (24 VAC)
to the control is cycled.

Defrost Cycle Initiation

The control will allow the heat pump to operate in the heating mode until
the combination of outdoor ambient and outdoor coil temperatures indi-
cate that a defrost cycle is necessary. 

The control will initiate a defrost cycle when the coil temperature is
below the initiate point for the measured ambient temperature (See Fig-
ure 14) continuously for 4-1/2 minutes. This delay eliminates unneces-
sary defrost cycles caused by refrigeration surges such as those that
occur at the start of a heating cycle.

The control will initiate a defrost cycle every 6 hours (accumulated com-
pressor run time) to recirculate refrigerant lubricants. This forced
defrost timer will be reset and restarted following the completion or ter-
mination of a defrost cycle.

The control shall initiate a defrost cycle when the Defrost Inhibit Time
Limit has elapsed if the previous defrost cycle was terminated based on
the Maximum Defrost Cycle Time. This shall occur regardless of the liq-
uid line (coil) temperature reading. The coil does not have to be cold for
the unit to be forced into defrost. Once the defrost cycle begins the con-
trol shall follow the normal defrost cycle routine.

The control will also initiate a defrost cycle when the TEST terminals
are shorted. This feature allows an installer or service technician to start
a defrost cycle immediately as required. When the TEST terminals are
shorted for more than 5 seconds with a Y input energized and the pres-
sure switch input is closed, the ASCD will be bypassed, the reversing
valve will be energized, the ODF will be de-energized and the compres-
sor and the Wout terminal to auxiliary heat will be energized.

When the TEST inputs are used to force a defrost cycle, the control will
ignore the state of the coil temperature and outdoor ambient tempera-
ture inputs. The coil does not have to be cold and the outdoor tempera-
ture does not have to be within a certain range for the heat pump to be
forced into a defrost cycle. After the TEST input jumper is removed, the
defrost mode will be terminated as normal. The defrost cycle length
timer will not be started until the TEST input is removed. If the TEST ter-
minals remain shorted, the control will keep the unit in defrost mode.

Defrost Inhibition

The control will not initiate a defrost cycle if the liquid line temperature is
above 40°F unless the defrost cycle is forced using the TEST input, or
the previous defrost exited on maximum time (12 minutes).

The control will also prevent a defrost cycle from being initiated too
soon after the initiation of the previous defrost cycle. When power is
applied to the control and after the completion or termination of each
defrost cycle, the control will start a 40-minute timer. When this timer
expires, the control will allow another defrost cycle when needed. The
timer is based on accumulated compressor run time.

Defrost Termination

The control will terminate the defrost cycle immediately after the liquid
line temperature reaches the terminate temperature or after 12 minutes
of defrost operation. See Figure 14.

The control will do the following to terminate a defrost cycle:

Energize the outdoor fan.

De-energize the reversing valve.

De-energize the auxiliary heat output through the Wout terminal.

Reset and restart the 40-minute defrost inhibit timer.

 FIGURE 14: 

Defrost Operation Curves

RE

G

ION C

TER

M

INATE CURVE

IN

H

I

B

IT CURVE

INITIA

TE

CUR

VE

RE

G

ION A

RE

G

ION 

B

RE

G

ION D

RE

G

ION E

A

MB

IENT TE

M

PERATURE

LIQUID LINE 

(

COIL

)

TE

M

PERA

TURE

D

e

f

rost

 

prevente

d f

rom

 

starting

N

o

 

ca

ll f

or

 d

e

f

rost

T

ime

 D

e

f

rost

 

(6

 

hour)

 

prevente

d

N

o

 

ca

ll f

or

 D

e

f

rost

T

ime

 D

e

f

rost

 

(6

 

hour)

 

a

ll

owe

d

C

a

ll f

or

 D

e

f

rost

D

e

f

rost

T

erminate

d

A

01

44

-001

Summary of Contents for 14 SEER-TH4 SERIES

Page 1: ...ng indoor coils can be used with a thermostatic expansion valve TXV Refer to the Tabular Data Sheet or to the Technical Guide for the proper selection SECTION II SAFETY This is a safety alert symbol W...

Page 2: ...e preferred method is to weigh in the charge For charging or checking the system charge at 55 F or below refer to the Optional Cold Weather Charging procedures near the end of SECTION VI SYSTEM CHARGE...

Page 3: ...ess and serviceability as well as the possible sound and vibration transmission into the structure These applications are best served by a properly engineered solution UNIT PLACEMENT 1 Provide a base...

Page 4: ...internally clean and dry system PRECAUTIONS DURING BRAZING SERVICE VALVE Precautions should be taken to prevent heat damage to service valve by wrapping a wet rag around it as shown in Figure 4 Also...

Page 5: ...ischarged loosen and remove the Schrader core 3 Place a backup wrench on distributor loosen and remove brass distributor nut Retain brass nut for use on liquid line Keep teflon washer in place and dis...

Page 6: ...gerant charge added accordingly MEASURE INDOOR AIR FLOW To determine rated air flow for a specific match consult the technical lit erature at www upgnet com When attempting to match this air flow sele...

Page 7: ...control box can swing open by removing the screw from the center of each side of the control box and allowing the control box to lower an inch or so into a pivotal position The control box can then s...

Page 8: ...disconnect switch to the unit 4 Route wires from disconnect through power wiring exit provided and into the unit control box as shown in Figures 9 10 5 Install the proper size time delay fuses or cir...

Page 9: ...www upgnet com in the Product Catalog Section INDOOR CUBIC FEET PER MINUTE CFM SELEC TION BOARD SETTINGS Typical Refer to the indoor unit Installation Manual instructions for the air han dler or furna...

Page 10: ...owing table summarizes the behavior of the control when the two TEST pins are connected More detailed descriptions of the various functions are included in other sec tions of this document TABLE 3 TES...

Page 11: ...arrangement of the refrigeration circuit within the coil The control may initiate a defrost cycle even when the coil is not completely cov ered with frost This is normal operation The control regulat...

Page 12: ...cur regardless of the liq uid line coil temperature reading The coil does not have to be cold for the unit to be forced into defrost Once the defrost cycle begins the con trol shall follow the normal...

Page 13: ...h code The control will reset the soft lockout condition when any of the follow ing occur after removal of the fault condition 1 Power is cycled to the R or Y inputs of the control This will cause the...

Page 14: ...AL SHOCK OPEN REMOTE DISCONNECT SO ELECTRICAL SUPPLY TO HEAT PUMP IS SHUT OFF COMPONENTS SHOWN IN DASH LINES ARE OPTIONAL DUAL CAPACITOR SHOWN SEPARATE CAPACITORS MAY BE USED ON ACTUAL UNIT WIRING MUS...

Page 15: ...5121495 UIM D 0516 Johnson Controls Unitary Products 15 NOTES...

Page 16: ...plicable Electrical Line Voltage Outdoor Unit Model Outdoor Unit Serial Filter Thermostat Accessories Filter Location s Connections Per Installation Instructions and Local Codes Gas piping is connecte...

Page 17: ...mp Cut Out Balance Point Defrost Curve Y2 Lock FFUEL Switch Point Hot Heat Pump Fill in the information ie ON OFF or the appropriate Value for the fields that apply to the defrost control board instal...

Page 18: ...des 5121495 UIM C 0316 York International Corp 5005 York Drive Norman OK 73069 Explain operation of system to equipment owner Explain the importance of regular filter replacement and equipment mainten...

Reviews: