1. We mount the handles. Two handles per meter of curtain track,
and one for each following meter of curtain track.
Mount the motor in the holder, then move
the protection until it snaps into the motor.
2. Place the curtain track on the handles.
3. Installation
4. Connecting
5. Connecting and configurating of the switch
2
Installation of the tubular motor should be performed by specialists with 1kV or higher SEP-certified electrician's licence
(SEP - Association of Polish Electrical Engineers) or equal license. Device is designed to operate in places shielded from
unfavourable weather conditions. Motor should be installed in accordance with all provisions of regional law and profes-
sional standards. All cables connecting power receiver with electric source should be protected from overload and
short-circuits effects with devices automatically disconnecting power. Device should be powered with a separate source
and protected only with a fast-blow fuse (never slow-blow fuse). Creating electrical system using inadequate fuse may
result in loosing rights under the provisions of warranty. When connecting device to power source with cables with
adequate cross-section should be used. Long-lasting output load capacity table should be the ground for choosing
adequate cables.
1. Connect the switch to the socket using the RJ plug. For mounting the RJ plug, use the right tools for it.
2. The motor can work in one of four switch modes:
I MODE - ASTABLE SWITCH FOR BLINDS:
a) A short circuit between wires 1 and 3 causes open or close the curtain.
b) A short circuit between wires 1 and 4 closes or stops the curtain.
brown wire - phaze
230 V / 50 Hz
yellow-green wire - protective
blue wire - neutral
4
3
2
1
close
open
common wire
1
4