Yolanda SP10A User Manual Download Page 3

Page   

3

  / 

35

 

 

 

Foreword 

Thank you for purchasing the Upper Arm Blood pressure Monitor. The blood pressure monitor uses the 
oscillometric method of blood pressure measurement. This means the monitor detects your blood’s 
movement through your brachial artery and converts the movements into a digital reading. An oscillometric 
monitor does not need a stethoscope so the monitor is simple to use. 
The 

Upper Arm Blood pressure Monitor was clinically investigated according to the requirements of ISO 81060-

2

 

 
Please read this instruction manual thoroughly before using the unit. 
Please keep for future reference. 
For specific information about your own blood pressure, CONSULT YOUR DOCTOR.

 

Intended use 

The Upper Arm Blood pressure Monitor is intended to measure the systolic and diastolic blood pressures 
and pulse rate of an adult individual. 
 
Measurement environment: hospital and home. 
Intended placement of the cuff: upper left arm.   

Intended users   

1. Adult 
2. Have 9 years intensive reading experience 
3. Can be read and understand the user manual 
4.The device can be used by non-professionals, users should consult medical professionals. 

1

Warning instructions and precautions 

The warning signs and graphic symbols in the manual are intended to enable you to use the product safely 
and correctly and to prevent harm to you and others.Warning marks and graphic symbols are described as 
follows: 

Warning/precautions symbols

 

 

Warning: Means a possibility of personal injury in case of improper use.

 

 

Caution: Means a possibility of personal injury or property damage in case of improper use.

 

 
 

PROHIBITION 

Means Forbidden with detailed items expressed in words or figures within or beside the mark. 
Left one means General Forbidden. 

 

Represents enforcement (what must be obeyed). Specific mandatory content is 
represented in or near

  by text or graphics: "general mandatory"

 

 

Summary of Contents for SP10A

Page 1: ...Page 1 35 Upper Arm Blood pressure Monitor User Manual Model SP10A SP10B SP10C...

Page 2: ...URE 7 4 Product introduction 8 5 Charging battery 11 6 Directions for use 12 7 Clean the monitor and cuff 24 8 Calibration and maintenance 25 9 Error indicators and troubleshooting 25 10 Storage 26 11...

Page 3: ...individual Measurement environment hospital and home Intended placement of the cuff upper left arm Intended users 1 Adult 2 Have 9 years intensive reading experience 3 Can be read and understand the u...

Page 4: ...e do not place heavy objects on it do not bind twist when using Otherwise it may cause fire or electric shock Please unplug the power plug before servicing this product Otherwise there will be danger...

Page 5: ...r intravenous drip and blood transfusion Otherwise symptoms may worsen Other Cautions Do not disassemble or repair or modify the main unit and cuff of the blood pressure monitor Otherwise it cannot be...

Page 6: ...ged impairment of the circulation of the blood of the patient Too frequent measurements can cause injury to the patient due to blood flow interference Do not apply of the cuff and its pressurization o...

Page 7: ...ea Talking during measurement When nervous or emotionally unstable measurement with the posture of abdominal compression Body movement during measurement When room temperature changes rapidly When the...

Page 8: ...unit and cuff 4 2 LCD display The display will be different for different models as shown in the table below Display Backlight Applicable Model VA LCD Yes SP10A TN LCD Yes SP10B TN LCD No SP10C 4 3 C...

Page 9: ...mmHg 6 7 36 0 kPa Diastolic Blood Pressure 30 220 mmHg 4 0 29 3 kPa Pulse 40 180 beats minute Accuracy Pressure 3mmHg 0 4kPa Pulse 5 Resolution ratio 1mmHg 0 133kPa Pressure displayed range 0 290mmHg...

Page 10: ...nd to WiFi via Bluetooth 3 After the measurement is completed the device will check whether WiFi is bound If WiFi is bound the data will be automatically uploaded to the corresponding user account of...

Page 11: ...ice in time Charge the battery as below Connect the USB line to the power adapter then insert another end of USB line to the Charge hole of device then insert Power adapter plug into supply power sock...

Page 12: ...onitor and battery Whenever the device is not used frequently charge the battery once a month 6 Directions for use 6 1 System setting 1 Unit setting Keeping press the user 1 button about 3s the LCD wi...

Page 13: ...mory button to increase the cycle of the minute press the user 2 button to confirm and finish the setting 6 After setting the LCD will display done and enter sleep mode 2 seconds later 7 In the date t...

Page 14: ...LCD shows it means that it is worn correctly and you can continue to measure If is displayed it means incorrect wearing Please wear it again according to the above requirements 6 2 2 Correct measuring...

Page 15: ...rement procedure 1 After the cuff has been appropriately positioned press the User1 or User2 button to turn on the device the LCD will fully display for 1s and then enter measure mode Before the measu...

Page 16: ...e If you have severe arrhythmia it is very likely that you will not be able to measure the blood pressure 6 4 Voice broadcast Broadcast state Broadcast content Start measure Start measuring now Finish...

Page 17: ...down the monitor will shut down automatically after 1 minute Automatic replacement For each user group if the stored measurement results exceed 99 groups the oldest historical data will be automatical...

Page 18: ...oad and Installation Search Runcobo note in the App Store or other App markets to download and install the App 6 6 2 APP installation Click get to install after verification After the installation is...

Page 19: ...APP Registration After installed the APP open it and then complete registration follow the instruction on APP interface 6 6 4 Connect with APP and blood pressure monitor via Bluetooth 1 Turn on the B...

Page 20: ...or a Click Add Blood Pressure Monitor and wait for the monitor to connect with APP as below figure b Turn on the monitor and start measure the blood pressure When the measurement is finished the blood...

Page 21: ...d pressure monitor until the binding completed as below 6 6 5 Connect with APP and blood pressure monitor via WiFi 1 Select 2 4GHz WiFi to connect as below figure 2 Enter the WiFi password and wait fo...

Page 22: ...lood pressure When the measurement is finished the blood pressure value is displayed on the LCD of monitor and then APP will search the monitor automatically When the APP connect with the monitor comp...

Page 23: ...e the historical data follow below figure 6 6 7 FAQ Click the FAQ on APP interface to see the help for frequently asked questions as below figures XXX 6 6 8 APP update 1 Click on the avatar on the hom...

Page 24: ...update to update 3 When update changes to open it means the update is complete click open to open the app 7 Clean the monitor and cuff Clean the monitor and wrist cuff 1 Make sure the monitor is off...

Page 25: ...curacy of measurement please do not disassemble or modify the Upper Arm Blood Pressure Monitor without permission If you find quality problems please call the customer service hotline 9 Error indicato...

Page 26: ...ge environment store in accordance with the storage environment conditions specified in this manual avoid moisture high temperature falling dust sun exposure vibration chemicals or corrosive gas etc 1...

Page 27: ...int in the EU countries 2002 96 EC WEEE Directive If you have any queries please refer to the local authorities responsible for waste disposal NOTES Handing of battery and wastes method please act acc...

Page 28: ...er Manual 15 Electromagnetic Compatibility Statement The equipment with following ESSENTIAL PERFORMANCE is intended used in Home healthcare environment and professional healthcare facility environment...

Page 29: ...used at entrances or exits of department stores libraries and other public places and airport security screening devices may affect the monitor Additionally RFID devices which are often used to read...

Page 30: ...tomer or the user of the upper arm blood pressure monitor should assure that it is used in such an environment Immunity test IEC 60601 1 2 test level Compliance level Electromagnetic environment guida...

Page 31: ...40 66 MHz to 40 70 MHz The amateur radio bands between 0 15 MHz and 80 MHz are 1 8 MHz to 2 0 MHz 3 5 MHz to 4 0 MHz 5 3 MHz to 5 4 MHz 7 MHz to 7 3 MHz 10 1 MHz to 10 15 MHz 14 MHz to 14 2 MHz 18 07...

Page 32: ...s equipment IEC 61000 4 3 See the following table Complies Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment Test frequency MHz Band a MHz Service a Modulationb M...

Page 33: ...age caused by force majeure such as natural disasters such as earthquake fire etc When you need warranty service please show your warranty card If you can t show your warranty card or prove that the p...

Page 34: ...his equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However the...

Page 35: ...na Tel 86 755 21635022 Customer service hotline 86 400 998 2913 service time 9 00 to 21 00 of working day Email service yolanda hk Website www yolanda hk Document No 20210501V1 0 User manual Edition V...

Reviews: