6
Installation
1
)
When separating the burner tile from the pilot burner body, remove the body first.
2
)
To facilitate the replacement of the heat storage body, mount so that the selector valve is
vertically.
3
)
Back up the outer surface of the burner tile, particularly the lower portion of the outer
surface, with fire brick, castable refractory or the like to prevent the burner tile from
dropping.
4
)
When mounting the burner to the furnace body, fill the gap between the mounting port
and the burner tile with fire mortar or the like for fixing.
5
)
Install the burner so that air can be taken in from below and air is exhausted from above.
6
)
Provide a space behind the burner enough for pulling out the burner gun from the burner
for the maintenance purpose.
Summary of Contents for HOPE CRU-10
Page 11: ...10 Flow sheet...
Page 18: ...17 Structural drawing...