IM 05C01E12-41E
7
■
UT150 Terminal Arrangement (Standard type)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
TC Input
DC mV or V Input
RTD Input
Measured Value (PV) Input
7
8
7
8
6
7
8
+
–
+
–
B
b
A
ALM2
ALM1
COM
Alarm Outputs
When “/AL” or “/HBA”
is specified.
When “/HBA”
is specified.
When “/RET”
is specified.
Universal input-selectable
input type
RS-485
3
4
5
RSB(+)
RSA(–)
SG
When “/RS” is specified.
Heater Current Detection Input
Retransmission Output
(Note 1)
1
2
11
12
13
+
–
1
2
CT
External Contact Inputs
3
4
5
SP2
STOP
TMR
STOP
COM
When “/EX” is specified.
Relay Contact Output
4 to 20 mA DC Output
Voltage Pulse Output
Control Output
Specify one for the output signal type.
14
15
14
15
+
–
14
15
+
–
NO
COM
Power Supply
9
L
N
10
9
AC/DC 24V
10
+
–
100-240V AC
When
⬙
/V24
⬙
is specified.
CAUTION
To prevent damage to
the controller, never provide
100-240V AC power supply
for power supply AC/DC 24V
model (when
⬙
/V24
⬙
is
specified).
NOTE
TMR
STOP
SP2
STOP
Parameter DIS
0 (Default)
1
2
SP1/SP2
switching
SP2
when DI=ON
Timer starts
when DI=ON
Timer stops
when DI=OFF
Timer starts
when DI=ON
Timer stops
when DI=OFF
RUN/STOP
switching
STOP
when DI=ON
SP1/SP2
switching
SP2
when DI=ON
RUN/STOP
switching
STOP
when DI=ON
NOTE
The and stand for
the polarity for DC 24V
power supply.
+
–
■
UT150 Terminal Arrangement (Heating/cooling type)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
TC Input
DC mV or V Input
RTD Input
7
8
7
8
6
7
8
+
–
+
–
B
b
A
NO
COM
ALM2
ALM1
COM
Relay Contact Output
4 to 20 mA DC Output
Voltage Pulse Output
Heating-side Control Output
Alarm Outputs
When “/AL” or “/HBA”
is specified.
Specify one for the output signal type.
RS-485
3
4
5
RSB(+)
RSA(–)
SG
When “/RS” is specified.
11
12
13
14
15
14
15
+
–
14
15
+
–
4 to 20 mA DC Output
Voltage Pulse Output
Cooling-side Control Output
Specify one for the
output signal type.
NO
COM
Relay Contact Output
1
2
+
–
1
2
1
2
+
–
(Note 1)
Heater Current Detection Input
3
4
CT
When “/HBA” is specified.
Note 1: The heater current detection input terminals (option code: /HBA)
are defined as terminals and for a standard type and as
terminals and for a heating/cooling type.
1
2
3
4
Measured Value (PV) Input
Universal input-selectable
input type
Power Supply
9
L
N
10
9
AC/DC 24V
10
+
–
100-240V AC
When
⬙
/V24
⬙
is specified.
CAUTION
To prevent damage to
the controller, never
provide 100-240V AC
power supply for power
supply AC/DC 24V
model (when
⬙
/V24
⬙
is
specified).
NOTE
External Contact Inputs
3
4
5
SP2
STOP
TMR
STOP
COM
When “/EX” is specified.
TMR
STOP
SP2
STOP
Parameter DIS
0 (Default)
1
2
SP1/SP2
switching
SP2
when DI=ON
Timer starts
when DI=ON
Timer stops
when DI=OFF
Timer starts
when DI=ON
Timer stops
when DI=OFF
RUN/STOP
switching
STOP
when DI=ON
SP1/SP2
switching
SP2
when DI=ON
RUN/STOP
switching
STOP
when DI=ON
(Heating/coolin Type)
NOTE
The and
stand for the polarity for
DC 24V power supply.
+
–