IM 05C01E12-41E
8
■
UT152/UT155 Terminal Arrangement (Standard type)
Note: The terminal arrangements of the UT152 and
UT155 are the same.
11
21
22
23
24
25
26
27
28
29
30
12
13
14
15
16
17
18
19
20
TC Input
DC mV or V Input
RTD Input
12
13
12
13
11
12
13
+
–
+
–
B
b
A
RS-485
26
27
28
RSB(+)
RSA(–)
SG
When “/HBA”
is specified.
When “/RET”
is specified.
Specify one for the output signal type.
When “/RS”
is specified.
Relay Contact Output
4 to 20 mA DC Output
Voltage Pulse Output
Control Output
14
15
14
15
+
–
14
15
+
–
Retransmission Output
+
–
29
30
Heater Current Detection Input
24
25
CT
When “/AL” or “/HBA”
is specified.
ALM2
ALM1
COM
Alarm Outputs
16
17
18
Measured Value (PV) Input
Universal input-selectable
input type
NO
COM
Power Supply
19
L
N
20
19
AC/DC 24V
20
+
–
100-240V AC
When
⬙
/V24
⬙
is specified.
CAUTION
To prevent damage to
the controller, never provide
100-240V AC power supply
for power supply AC/DC 24V
model (when
⬙
/V24
⬙
is
specified).
NOTE
External Contact Inputs
21
22
23
SP2
STOP
TMR
STOP
COM
When “/EX” is specified.
TMR
STOP
SP2
STOP
Parameter DIS
0 (Default)
1
2
SP1/SP2
switching
SP2
when DI=ON
Timer starts
when DI=ON
Timer stops
when DI=OFF
Timer starts
when DI=ON
Timer stops
when DI=OFF
RUN/STOP
switching
STOP
when DI=ON
SP1/SP2
switching
SP2
when DI=ON
RUN/STOP
switching
STOP
when DI=ON
NOTE
The and stand for the polarity
for DC 24V power supply.
+
–
■
UT152/UT155 Terminal Arrangement (Heating/cooling type)
11
21
22
23
24
25
26
27
28
29
30
12
13
14
15
16
17
18
19
20
TC Input
DC mV or V Input
RTD Input
12
13
12
13
11
12
13
+
–
+
–
B
b
A
RS-485
26
27
28
RSB(+)
RSA(–)
SG
Specify one for the output signal type.
When “/RS”
is specified.
Relay Contact Output
4 to 20 mA DC Output
Voltage Pulse Output
Heating-side Control Output
14
15
14
15
+
–
14
15
+
–
Heater Current Detection Input
24
25
CT
When “/AL” or “/HBA”
is specified.
ALM2
ALM1
COM
Alarm Outputs
16
17
18
Note: The terminal arrangements of the UT152 and
UT155 are the same.
NO
COM
Specify one for the output signal type.
Relay Contact Output
4 to 20 mA DC Output
Voltage Pulse Output
Cooling-side Control Output
29
30
+
–
29
30
29
30
+
–
NO
COM
Measured Value (PV) Input
Universal input-selectable
input type
Power Supply
19
L
N
20
19
AC/DC 24V
20
+
–
100-240V AC
When
⬙
/V24
⬙
is specified.
CAUTION
To prevent damage to
the controller, never provide
100-240V AC power supply
for power supply AC/DC 24V
model (when
⬙
/V24
⬙
is
specified).
NOTE
External Contact Inputs
21
22
23
SP2
STOP
TMR
STOP
COM
When “/EX” is specified.
TMR
STOP
SP2
STOP
Parameter DIS
0 (Default)
1
2
SP1/SP2
switching
SP2
when DI=ON
Timer starts
when DI=ON
Timer stops
when DI=OFF
Timer starts
when DI=ON
Timer stops
when DI=OFF
RUN/STOP
switching
STOP
when DI=ON
SP1/SP2
switching
SP2
when DI=ON
RUN/STOP
switching
STOP
when DI=ON
When “/HBA” is specified.
NOTE
The and stand for the polarity
for DC 24V power supply.
+
–
Summary of Contents for UT150
Page 23: ......