
Commands
3-7
IM 704310-12E
3
Command
Function
Page
:THIStogram:ISI:SIZE
Sets the number of windows or queries the current setting.
3-52
:THIStogram:ISI:SPACe<x>
Sets the space or queries the current setting.
3-53
:THIStogram:ISI[:STATe]
Turns ON/OFF the inter-symbol interference analysis function or queries the current
setting.
3-53
:THIStogram:ISI:TARGet
Sets the item to be analyzed or queries the current setting.
3-53
:THIStogram:ISI:TRIGger
Sets the trigger condition or queries the current setting.
3-53
:THIStogram:ISI:TVALue
Sets the value of the constant T or queries the current setting.
3-53
:THIStogram:ISI:UPDate
Changes the window setting based on the constant T.
3-53
:THIStogram:ISI:WINDow<x>?
Queries all settings related to each window.
3-53
:THIStogram:ISI:WINDow<x>:HORizontal?
Queries all settings related to the horizontal axis of each window.
3-53
:THIStogram:ISI:WINDow<x>:HORizontal:CENTer
Sets the center value of the horizontal axis or queries the current setting.
3-53
:THIStogram:ISI:WINDow<x>:HORizontal:SPAN
Sets the width of the horizontal axis or queries the current setting.
3-54
:THIStogram:ISI:WINDow<x>:LABel
Sets the label of each window or queries the current setting.
3-54
:THIStogram:ISI:WINDow<x>:MARKer?
Queries all settings related to the horizontal marker cursor of each window.
3-54
:THIStogram:ISI:WINDow<x>:MARKer:LEFT
Sets the position of the left marker or queries the current setting.
3-54
:THIStogram:ISI:WINDow<x>:MARKer:RIGHt
Sets the position of the right marker or queries the current setting.
3-54
:THIStogram:MARKer?
Queries all settings related to the markers.
3-54
:THIStogram:MARKer:LEFT
Sets the position of the left marker or queries the current setting.
3-54
:THIStogram:MARKer:LOW
Sets the position of the low marker or queries the current setting.
3-54
:THIStogram:MARKer:LVALue?
Queries the frequency at the left marker position.
3-54
:THIStogram:MARKer:RIGHt
Sets the position of the right marker or queries the current setting.
3-55
:THIStogram:MARKer:RVALue?
Queries the frequency at the right marker position.
3-55
:THIStogram:MARKer[:STATe]
Turns ON/OFF the marker or queries the current setting.
3-55
:THIStogram:VERTical?
Queries all settings related to the vertical axis.
3-55
:THIStogram:VERTical:AXIS
Sets the type of vertical axis scale or queries the current setting.
3-55
:THIStogram:VERTical:HIGH
Sets the upper limit of the vertical axis scale or queries the current setting.
3-55
TVARiation Group
:TVARiation?
Queries all settings related to the time variation display.
3-56
:TVARiation:HORizontal?
Queries all settings related to the horizontal axis of the time variation display.
3-56
:TVARiation:HORizontal:MINimum
Sets the left end of the horizontal axis scale or queries the current setting.
3-57
:TVARiation:HORizontal:SPAN
Sets the width of the horizontal axis scale or queries the current setting.
3-57
:TVARiation:MARKer?
Queries all settings related to the markers.
3-57
:TVARiation:MARKer:HIGH
Sets the position of the high marker or queries the current setting.
3-57
:TVARiation:MARKer:LEFT
Sets the position of the left marker or queries the current setting.
3-57
:TVARiation:MARKer:LOW
Sets the position of the low marker or queries the current setting.
3-57
:TVARiation:MARKer:LVALue?
Queries the measured value at the left marker position.
3-57
:TVARiation:MARKer:RIGHt
Sets the position of the right marker or queries the current setting.
3-57
:TVARiation:MARKer:RVALue?
Queries the measured value of the right marker position.
3-57
:TVARiation:MARKer[:STATe]
Turns ON/OFF the marker cursor or queries the current setting.
3-57
:TVARiation:VERTical?
Queries all settings related to the vertical axis.
3-57
:TVARiation:VERTical:CENTer
Sets the center value of the vertical axis or queries the current setting.
3-58
:TVARiation:VERTical:SPAN
Sets the width of the vertical axis or queries the current setting.
3-58
UNIT Group
:UNIT?
Queries the default units for voltage, time, and frequency.
3-58
:UNIT:VOLTage
Sets the default unit for voltage or queries the current setting.
3-58
:UNIT:TIME
Sets the default unit for time or queries the current setting.
3-58
3.1 Command Listing