FCN Installation Guide 

(Marine Standards)

TI 34P02Q93-01E

TI 34P02Q93-01E

©Copyright Oct. 2018 (YK)

2nd Edition Feb. 25, 2019 (YK)

Yokogawa Electric Corporation

2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan

Tel.: 81-422-52-5616  URL: http://www.stardom.biz

Summary of Contents for STARDOM FCN

Page 1: ...tallation Guide Marine Standards TI 34P02Q93 01E TI 34P02Q93 01E Copyright Oct 2018 YK 2nd Edition Feb 25 2019 YK Yokogawa Electric Corporation 2 9 32 Nakacho Musashino shi Tokyo 180 8750 Japan Tel 81...

Page 2: ...Blank Page...

Page 3: ...general installation of the FCN 500 refer to FCN FCJ Installation Guide TI 34P 02Q91 01E IMPORTANT Notation in this document The term FCN 500 refers to the autonomous controllers with NFCP501 NFCP502...

Page 4: ...cates precautions to avoid a danger that may lead to minor or moderate injury or property damage IMPORTANT Identifies important information required to understand operations or functions TIP Identifie...

Page 5: ...OM and FAST TOOLS are trademarks of YOKOGAWA All other company and product names mentioned in this manual are trademarks or registered trademarks of their respective companies We do not use TM or mark...

Page 6: ...Blank Page...

Page 7: ...M FCN Installation Guide Marine Standards Feb 25 2019 00 CONTENTS TI 34P02Q93 01E 2nd Edition Introduction i Safety Precautions ii Copyright and Trademark Notices iii 1 Compliance with Marine Standard...

Page 8: ...Blank Page...

Page 9: ...au Veritas BV Rules for the Classification of Steel ships January 2018 edition Part C Chapter 3 Section 6 EC Code 31 Lloyd s Register Lloyd s Register Type Approval System Test Specification Number 1...

Page 10: ...0 mA 4 channel input 4 channel output Isolated channels NFAP135 5 Pulse Input Module 8 channel Pulse count 0 to 10 kHz Isolated channels Digital I O Modules NFDV151 6 Digital Input Module 32 channel 2...

Page 11: ...devices such as noise filters and ferrite cores to the cables connecting each component Installation of Power line Noise Filter Attach a noise filter on the power line for the following components FCN...

Page 12: ...Noise Filter 3 Noise Filter 1 Tap Noise Filter 2 Noise Filter 2 Power feed c Power feed Power feed 1 This noise filter is for FCN 500 power supply line Refer to Table Example Noise filte for FCN 500...

Page 13: ...module NFAR181 Signal cable ZCAT3035 1330 2 2 NFAI141 KMS40 cable ZCAT3035 1330 4 3 Signal cable ZCAT3035 1330 4 2 NFAI541 KMS40 cable ZCAT3035 1330 4 3 Signal cable ZCAT3035 1330 4 2 NFAI143 KMS40 ca...

Page 14: ...NPW44x N2EB100 NPW44x N2EB100 IOM IOM IOM IOM for N2EB100 for N2EB100 IOM IOM IOM IOM Note IOM is abbreviation of Input Output Modules Note Figures in show the locations listed in Table Cables that N...

Page 15: ...6 External Power Supply Unit Note IOM is abbreviation of Input Output Modules Note Figures in show the locations listed in Table Cables that Need Ferrite Cores to be Attached to and Ferrite Core Mode...

Page 16: ...o each connector In order to prevent the load at the connectors secure the cables to the cabinet frame or dummy plate using cable ties at the nearest possible place to each ferrite core Vinyl insulate...

Page 17: ...lates Space Size UNITs in Height Dummy Plate 1 UNIT 44 45 mm 1 T9082EX 2 T9933VF 3 T9082EY 6 T9082EZ Specification of EMI shielding gasket Width 5 mm Thicness 1 mm Location to attach EMI shielding gas...

Page 18: ...r When Leaving a Large Space between Unit Components SEE ALSO For how to attach EMI shielding gaskets refer to When Leaving a Large Space between Unit Components Dummy plate Dummy plate Dummy plate Du...

Page 19: ...on Revised Fig Wiring for power cable Feb 25 2019 00 Subject to change without notice n For Questions and More Information If you have any questions you can send an E mail to the following address E m...

Page 20: ...Blank Page...