<11. INSTRUCTIONS FOR PED>
11-2
IM 01R01B02-00E-E 12th edition October 01, 2014 -00
All Rights Reserved. Copyright © 2003, Rota Yokogawa
Dependence of the permissible max. effective pressure of the operating temperature:
The pressure relevant temperature limits of the RAMC are: -200 to 370°C for units made from 1.4571/1.4404.
-80 to 130°C for units made from PTFE.
These limits are reduced by metrological boundary conditions. (see temperature curves and table).
Process connection
Process temperature
-200°C
RT
(20°C)
50°C
100°C
150°C
200°C
250°C
300°C
350°C
370°C
A1
Flange ASME 150lbs
19 bar
19 bar 18.4 bar 16.2 bar 14.8 bar 13.7 bar 12.1 bar 10.2 bar 8.4 bar 7.4 bar
A2
Flange ASME 300lbs
49.6 bar 49.6 bar 48.1 bar 42.2 bar
38.5 bar 35.7 bar
33.4 bar 31.6 bar 30.3 bar 29.9 bar
A3
Flange ASME 600lbs
99.3 bar 99.3 bar 96.2 bar 84.4 bar
77 bar 71.3 bar 66.8 bar 63.2 bar 60.7 bar
59.8 bar
D2
Flange EN PN16
16 bar
16 bar
15.6 bar
14.2 bar 12.8 bar 11.7 bar 10.9 bar 10.3 bar 9.9 bar 9.6 bar
D4
Flange EN PN40
40 bar
40 bar 39.1 bar
35.6 bar
32 bar 29.3 bar 27.2 bar
25.8 bar
24.7 bar
24 bar
D5
Flange EN PN63
63 bar
63 bar 61.6 bar
56 bar 50.4 bar
46.2 bar 42.8 bar 40.6 bar 38.9 bar 37.8 bar
D6
Flange EN PN100
100 bar 100 bar 97.8 bar 88.9 bar
80 bar 73.3 bar
68 bar 64.4 bar 61.8 bar
60 bar
R4/T4 Internal Thread RAMC01..
25 bar
25 bar
25 bar
25 bar
20 bar
20 bar
20 bar
20 bar
-------
-------
R4/T4 Internal Thread RAMC23..
25 bar
25 bar
25 bar
25 bar
20 bar
20 bar
20 bar
20 bar
-------
-------
R4/T4 Internal Thread RAMC02..
16 bar
16 bar
16 bar
16 bar
16 bar
16 bar
16 bar
16 bar
-------
-------
R4/T4 Internal Thread RAMC03..
16 bar
16 bar
16 bar
16 bar
16 bar
16 bar
16 bar
16 bar
-------
-------
R4/T4 Internal Thread RAMC05..
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
-------
-------
R4/T4 Internal Thread RAMC06..
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
-------
-------
G6/T6 Internal Thread RAMC01..
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
-------
-------
G6/T6 Internal Thread RAMC23..
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
-------
-------
G6/T6 Internal Thread RAMC02..
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
-------
-------
G6/T6 Internal Thread RAMC03..
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
-------
-------
G6/T6 Internal Thread RAMC06..
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
40 bar
-------
-------
Process temperature
-200°C
RT
(20°C)
50°C
100°C
140°C
see corresponding standard for the
connection
S2
Clamp. DIN 11851 RAMC02..
40 bar
40 bar
40 bar
40 bar
S2
Clamp. DIN 11851 RAMC05..
25 bar
25 bar
25 bar
25 bar
S2
Clamp. DIN 11851 RAMC06..
25 bar
25 bar
25 bar
25 bar
S2
Clamp. DIN 11851 RAMC08..
25 bar
25 bar
25 bar
25 bar
S2
Clamp. DIN 11851 RAMC10..
25 bar
25 bar
25 bar
25 bar
S2
Clamp. DIN 11851 RAMC12..
16 bar
16 bar
16 bar
16 bar
Process temperature
-200°C
RT
(20°C)
50°C
100°C
150°C
see corresponding standard for the
connection
S4
Clamp RAMC02..
16 bar
16 bar
16 bar
16 bar
S4
Clamp RAMC03..
16 bar
16 bar
16 bar
16 bar
S4
Clamp RAMC04..
16 bar
16 bar
16 bar
16 bar
S4
Clamp RAMC05..
16 bar
16 bar
16 bar
16 bar
S4
Clamp RAMC06..
10 bar
10 bar
10 bar
10 bar
S4
Clamp RAMC08..
10 bar
10 bar
10 bar
10 bar
S4
Clamp RAMC10..
10 bar
10 bar
10 bar
10 bar
S5
Rosista Flange RAMC02..
10 bar
see corresponding standard for the connection
S5
Rosista Flange RAMC04..
10 bar
Summary of Contents for RAMC
Page 2: ...Blank Page ...